A Disassembly-Free Offline Detection and Condition Monitoring Technique for Eccentricity Faults in Salient-Pole Synchronous Machines

被引:18
|
作者
Ilamparithi, T. [1 ]
Nandi, Subhasis [2 ]
Subramanian, Jayaram [2 ]
机构
[1] OPAL RT, Montreal, PQ H2K 2T6, Canada
[2] Univ Victoria, Dept Elect & Comp Engn, Victoria, BC V8W 2Y2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Condition monitoring; eccentricity; finite element (FE); frequency spectrum; residue estimation; saturation; synchronous machine; AIRGAP ECCENTRICITY; INDUCTION MACHINES; DIAGNOSIS; IDENTIFICATION;
D O I
10.1109/TIA.2014.2358797
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel scheme to reliably monitor the condition of static and dynamic eccentricity (DE) faults in salient-pole synchronous machines (SPSMs) through the standard short-circuit test is proposed in this paper. The detection technique is based on offline current signature analysis that does not require machine disassembly. The procedure is unaffected by machine saturation or supply voltage harmonics. In this scheme, DE fault is monitored by exploiting the presence of inherent static eccentricity (SE), whereas SE fault monitoring is achieved using residual estimation technique. The proposed method is found to work for both star and delta-connected machines. Results obtained from an experimental three-phase 2-kW SPSM have been used to validate the proposed eccentricity condition monitoring method.
引用
收藏
页码:1505 / 1515
页数:11
相关论文
共 21 条
  • [21] Pole Pair and Rotor Slot Number Independent Frequency Domain Based Detection of Eccentricity Faults in Induction Machines Using a Semi On-Line Technique
    Nandi, S.
    Ilamparithi, T.
    Lee, S. B.
    Hyun, D.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRIC MACHINES, POWER ELECTRONICS AND DRIVES, 2009, : 87 - +