Quantifying breast density with a cone-beam breast CT

被引:0
|
作者
Li, Xinhua [1 ]
Liu, Bob [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
Breast Density; Breast CT; Image Reconstruction; simulation; ALGORITHM;
D O I
10.1117/12.844369
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Volumetric breast density was evaluated using a simulated cone beam breast CT with 80 kVp. The breast was modeled as a cylinder with background tissue composition of 20% glandular and 80% adipose. Various objects with different sizes and tissue compositions were embedded. Ray-tracing algorithm was utilized to obtain projection images in a full rotation without considering scatter, beam hardening and imaging noise. Filtered backprojection was adopted for image reconstruction with high quality. Reconstructed images had flat profiles except at large cone angle of 8.6 degrees to 10 degrees. They were calibrated using known linear attenuation coefficients of two image contrast objects. A 3D mapping of tissue densities could be directly computed within 5% error. Tissue volumes were obtained by counting voxels in appropriate attenuation coefficient ranges. Results of contrast objects were consistent with true volumes within 10% error. However, cone angle artifact decreased pixel values, and a reduction algorithm was required for accurate tissue assessment at large cone angles. This study indicates the possibility of excellent quantitative breast density measurements and volume assessments with cone-beam breast CT.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comparison between cone-beam breast-CT and full-field digital mammography for microcalcification detection depending on breast density
    Wienbeck, Susanne
    Andrijevska, Viktorija
    Kueck, Fabian
    Perske, Christina
    Unterberg-Buchwald, Christina
    Fischer, Uwe
    Lotz, Joachim
    Kunze, Meike
    MEDICINE, 2023, 102 (22) : E33900
  • [22] Improving the spatial resolution characteristics of dedicated cone-beam breast CT technology
    Gazi, Peymon
    Boone, John M.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [23] Low-Dose Cone-Beam Breast CT: Physics and Technology Development
    Boone, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3829 - 3830
  • [24] Dedicated cone-beam breast CT: Feasibility study with surgical mastectomy specimens
    Yang, Wei Tse
    Carkaci, Selin
    Chen, Lingyun
    Lai, Chao-Jen
    Sahin, Aysegul
    Whitman, Gary J.
    Shaw, Chris C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) : 1312 - 1315
  • [25] Dedicated scanner for laboratory investigations on cone-beam CT/SPECT imaging of the breast
    Mettivier, Giovanni
    Russo, Paolo
    Cesarelli, Mario
    Ospizio, Roberto
    Passeggio, Giuseppe
    Roscilli, Lorenzo
    Pontoriere, Giuseppe
    Rocco, Raffaele
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 350 - 356
  • [26] Noise power properties of a cone-beam CT system for breast cancer detection
    Yang, Kai
    Kwan, Alexander L. C.
    Huang, Shih-Ying
    Packard, Nathan J.
    Boone, John M.
    MEDICAL PHYSICS, 2008, 35 (12) : 5317 - 5327
  • [27] 3D tumor measurement in cone-beam CT breast imaging
    Chen, ZK
    Ning, R
    MEDICAL IMAGING 2004: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2004, 5367 : 558 - 569
  • [28] Noise Power Properties of a Cone-Beam CT System for Breast Cancer Detection
    Yang, K.
    Kwan, A.
    Huang, S.
    Boone, J.
    MEDICAL PHYSICS, 2008, 35 (06) : 2977 - +
  • [29] Cone-beam CT breast imaging with a flat panel detector - a simulation study
    Chen, LY
    Shaw, CC
    Tu, SJ
    Altunbas, M
    Wang, T
    Lai, CJ
    Liu, XM
    Kappadath, SC
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 943 - 951
  • [30] Comparison of Dedicated Cone-Beam Breast CT with Conventional CT for Detection of Micro-Calcification
    Ge, S.
    Lai, C.
    Pan, T.
    Han, T.
    Chen, L.
    Shen, Y.
    Liu, X.
    Zhong, Y.
    Wang, T.
    Yi, Y.
    Zhang, H.
    You, Z.
    Shaw, C.
    MEDICAL PHYSICS, 2009, 36 (06) : 2441 - +