Optimization of magnetic field configuration for the production of Ar ions from RIKEN 18 GHz ECR ion source

被引:11
|
作者
Higurashi, Y
Nakagawa, T
Kidera, M
Kageyama, T
Aihara, T
Kase, M
Yano, Y
机构
[1] RIKEN, Cyclotron Ctr, Wako, Saitama 3510198, Japan
[2] SHI Accelerator Serv Ltd, Shinagawa Ku, Tokyo 1410001, Japan
关键词
electron-cyclotron resonance ion source; plasma electrode position; magnetic field configuration;
D O I
10.1016/S0168-9002(03)01815-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We successfully extracted a 1.9 mA Ar8+ ion beam and a 1 mA Ar9+ ion beam from the RIKEN 18 GHz ECR ion source at the extraction voltage of 17 kV and the microwave power of 700-800 W. To obtain these intensities, we optimized the magnetic field configuration and the plasma electrode position. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:206 / 210
页数:5
相关论文
共 50 条
  • [21] Production of multi-charged ions in the RIKEN 18 GHz ECRIS
    Nakagawa, T
    Higurashi, Y
    Kidera, M
    Aihara, T
    Kase, M
    Yano, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 226 (03): : 392 - 400
  • [22] Effect of axial magnetic field on a 2.45 GHz permanent magnet ECR ion source
    Nakamura, T.
    Wada, H.
    Asaji, T.
    Furuse, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [23] Magnetic field upgrade of argonne national laboratory 14 GHz ECR ion source
    Vondrasek, RC
    Scott, R
    Pardo, RC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (05): : 1532 - 1534
  • [24] Magnetic Field Design for a 2.45-GHz ECR Ion Source with Permanent Magnets
    Park, J. Y.
    Lee, H. S.
    Won, M. S.
    Lee, B. S.
    Kim, J. P.
    Yoon, J. H.
    Bae, J. S.
    Bang, J. K.
    Ahn, J. K.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (02) : 409 - 414
  • [25] Effect of electrode for producing the highly charged heavy ions from RIKEN 18 GHz electron cyclotron resonance ion source
    Kurita, T
    Nakagawa, T
    Kidera, M
    Miyazawa, Y
    Hemmi, M
    Chiba, T
    Inabe, N
    Kase, M
    Kageyama, T
    Kamigaito, O
    Goto, A
    Yano, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (6A): : 3707 - 3711
  • [26] Effect of electrode for producing the highly charged heavy ions from RIKEN 18 GHz electron cyclotron resonance ion source
    Kurita, Tetsuro
    Nakagawa, Takahide
    Kidera, Masanori
    Miyazawa, Yoshitoshi
    Hemmi, Masatake
    Chiba, Toshiya
    Inabe, Naohito
    Kase, Masayuki
    Kageyama, Tadashi
    Kamigaito, Osamu
    Goto, Akira
    Yano, Yasushige
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (6 A): : 3707 - 3711
  • [27] Production of metallic ions beam in ECR ion source
    Zhang, ZM
    Zhao, HW
    Zhao, YB
    Zhang, XZ
    Guo, XH
    Liu, ZW
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2000, 24 (10): : 974 - 978
  • [28] Production of metallic ions beam in ECR ion source
    2000, Sci Publ House (24):
  • [29] Effect of plasma electrode position on the beam intensity of heavy ions from a RIKEN 18 GHz electron cyclotron resonance ion source
    Higurashi, Y
    Nakagawa, T
    Kidera, M
    Aihara, T
    Kase, M
    Yano, Y
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 598 - 600
  • [30] A compact dc-break for ECR ion source @ 18 GHZ
    Leonardi, O.
    Torrisi, G.
    Sorbello, G.
    Celona, L.
    Gammino, S.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2018, 60 (12) : 3026 - 3029