Layer-by-layer chitosan-decorated pristine graphene on screen-printed electrodes by one-step electrodeposition for non-enzymatic hydrogen peroxide sensor

被引:18
|
作者
Zhu, Qin [1 ]
Liang, Bo [1 ]
Cai, Yu [1 ]
Cao, Qingpeng [1 ]
Tu, Tingting [1 ]
Huang, Bobo [1 ]
Fang, Lu [2 ]
Ye, Xuesong [1 ]
机构
[1] Zhejiang Univ, Innovat Ctr Minimally Invas Tech & Device, Coll Biomed Engn & Instrument Sci, Biosensor Natl Special Lab,Minist Educ,Key Lab Bi, Hangzhou 310027, Zhejiang, Peoples R China
[2] Hangzhou Dianzi Univ, Coll Life Informat Sci & Instrument Engn, Hangzhou 310018, Zhejiang, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Pristine graphene; Chitosan; Co-electrodeposition; Hydrogen peroxide biosensor; Screen-printed electrodes; OXIDE; REDUCTION; FUNCTIONALIZATION; NANOPARTICLES; FILMS;
D O I
10.1016/j.talanta.2018.07.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Layer-by-layer chitosan-decorated pristine graphene on screen-printed electrodes was achieved by one-step electrodeposition method and an enzyme-free hydrogen peroxide electrochemical biosensor was fabricated for its application. Negatively charged pristine graphene absorbed with positively charged chitosan by electrostatic interactions was electrodeposited on the electrodes. The successful immobilization of pristine graphene was confirmed by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and electrochemical characterizations. The graphene-chitosan volume ratio and cyclic voltammetry scan cycles during the electrodeposition process were optimized. The resulting hydrogen peroxide biosensors showed a 178 times improved sensitivity and exhibited two wide linear detection ranges from 20 mu M to 20 mM and from 20 mM to 60 mM. The biosensors also showed a good reproducibility, stability, selectivity and could be used in real samples detection. The superior electrochemical performance of graphene-chitosan was attributed to the preservation of excellent properties of pristine graphene, and the formation of layer-by-layer structure with high surface area. The proposed strategy of direct immobilization of pristine graphene can be extended for the immobilization of other nanomaterials and biomolecules.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 48 条
  • [1] Functionalized graphene oxide–polypyrrole–chitosan (fGO–PPy–CS) modified screen-printed electrodes for non-enzymatic hydrogen peroxide detection
    Muhammad Asim Akhtar
    Akhtar Hayat
    Naseer Iqbal
    Jean Louis Marty
    Mian Hasnain Nawaz
    [J]. Journal of Nanoparticle Research, 2017, 19
  • [2] Non-enzymatic xanthine sensor of heteropolyacids doped ferrocene and reduced graphene oxide via one-step electrodeposition combined with layer-by-layer self-assembly technology
    Zhu, Di
    Guo, Dongxuan
    Zhang, Lulu
    Tan, Lichao
    Pang, Haijun
    Ma, Huiyuan
    Zhai, Mo
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 281 : 893 - 904
  • [3] Functionalized graphene oxide-polypyrrole-chitosan (fGO-PPy-CS) modified screen-printed electrodes for non-enzymatic hydrogen peroxide detection
    Akhtar, Muhammad Asim
    Hayat, Akhtar
    Iqbal, Naseer
    Marty, Jean Louis
    Nawaz, Mian Hasnain
    [J]. JOURNAL OF NANOPARTICLE RESEARCH, 2017, 19 (10)
  • [4] Layer-by-layer electrodeposition of redox polymers and enzymes on screen-printed carbon electrodes for the preparation of reagentless biosensors
    Gao, Q
    Yang, MR
    [J]. CHEMICAL COMMUNICATIONS, 2004, (01) : 30 - 31
  • [5] Electrodeposition of nickel nanoflowers on screen-printed electrodes and their application to non-enzymatic determination of sugars
    Perez-Fernandez, Beatriz
    Martin-Yerga, Daniel
    Costa-Garcia, Agustin
    [J]. RSC ADVANCES, 2016, 6 (87): : 83748 - 83757
  • [6] Fabrication of high-performance non-enzymatic sensor by direct electrodeposition of nanomaterials on porous screen-printed electrodes
    Lin, Shih-Hao
    Lefeuvre, Elie
    Tai, Chun-Hao
    Wang, Hsiang-Yu
    [J]. JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2022, 137
  • [7] One-Step Electrodeposition to Layer-by-Layer Graphene-Conducting-Polymer Hybrid Films
    Tang, Yanhong
    Wu, Na
    Luo, Shenglian
    Liu, Chengbin
    Wang, Ke
    Chen, Liuyun
    [J]. MACROMOLECULAR RAPID COMMUNICATIONS, 2012, 33 (20) : 1780 - 1786
  • [8] Performance of layer-by-layer deposited low dimensional building blocks of graphene-prussian blue onto graphite screen-printed electrodes as sensors for hydrogen peroxide
    Michopoulos, Apostolos
    Kouloumpis, Antonios
    Gournis, Dimitrios
    Prodromidis, Mamas I.
    [J]. ELECTROCHIMICA ACTA, 2014, 146 : 477 - 484
  • [9] Nickel Hydroxide Nanoparticles on Screen-printed Electrodes as an Impedimetric Non-enzymatic Glucose Sensor
    Laura Rinaldi, Ana
    Sobral, Santiago
    Carballo, Romina
    [J]. ELECTROANALYSIS, 2017, 29 (08) : 1961 - 1967
  • [10] A Non-Enzymatic Electrochemical Sensor for Glyphosate Adopting Surface Modified Screen-Printed Electrodes
    Janjani, Prachi
    Bhardwaj, Upasana
    Gupta, Ragini
    Kushwaha, Himmat Singh
    [J]. ACS APPLIED ENGINEERING MATERIALS, 2023, 1 (01): : 359 - 368