Evaluation of success after second Ahmed glaucoma valve implantation

被引:15
|
作者
Nilforushan, Naveed [1 ]
Yadgari, Maryam [1 ]
Jazayeri, Anis Alsadat [1 ]
Karimi, Nasser [1 ]
机构
[1] Iran Univ Med Sci, Rassoul Akram Hosp, Eye Res Ctr, Tehran, Iran
关键词
Ahmed glaucoma valve; glaucoma; intraocular pressure; PEDIATRIC GLAUCOMA; DRAINAGE DEVICES; TUBE SHUNT; FAILURE; CYCLOPHOTOCOAGULATION; INSERTION; REVISION; SURGERY;
D O I
10.4103/0301-4738.181740
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the outcome of the second Ahmed glaucoma valve (AGV) surgery in eyes with failed previous AGV surgery. Design: Retrospective case series. Patients and Methods: Following chart review, 36 eyes of 34 patients with second AGV implantation were enrolled in this study. The primary outcome measure was surgical success defined in terms of intraocular pressure (IOP) control using two criteria: Success was defined as IOP %21 mmHg (criterion 1) and IOP %16 mmHg (criterion 2), with at least 20% reduction in IOP, either with no medication (complete success) or with no more than two medications (qualified success). KaplanuMeier survival analysis was used to determine the probability of surgical success. Results: The average age of the patients was 32.7 years (range 4u65), and the mean duration of follow-up was 21.4 months (range 6u96). Preoperatively, the mean IOP was 26.94 mmHg (standard deviation [SD] 7.03), and the patients were using 2.8 glaucoma medications on average (SD 0.9). The mean IOP decreased significantly to 13.28 mmHg (SD 3.59) at the last postoperative visit (P = 0.00) while the patients needed even fewer glaucoma medications on average (1.4 1.1, P = 0.00). Surgical success of second glaucoma drainage devices (KaplanuMeier analysis), according to criterion 1, at 6, 12, 18, and 42 months was 94%, 85%, 80%, and 53% respectively, and according to criterion 2, was 94%, 85%, 75%, and 45%, respectively. Conclusion: Repeated AGV implantation seems to be a safe modality of treatment with acceptable success rate in cases with failed previous AGV surgery.
引用
收藏
页码:206 / 210
页数:5
相关论文
共 50 条
  • [31] Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma
    Shen, Christopher C.
    Salim, Sarwat
    Du, Haiming
    Netland, Peter A.
    CLINICAL OPHTHALMOLOGY, 2011, 5 : 281 - 286
  • [32] Clinical Outcomes After Ahmed Glaucoma Valve Implantation for Pediatric Glaucoma After Congenital Cataract Surgery
    Geyer, Orna
    Segal, Adi
    Melamud, Alina
    Wolf, Alvit
    JOURNAL OF GLAUCOMA, 2021, 30 (01) : 78 - 82
  • [33] Evaluation of the hypertensive phase after insertion of the Ahmed Glaucoma Valve
    Nouri-Mahdavi, K
    Caprioli, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (06) : 1001 - 1008
  • [34] Long-term results after Ahmed glaucoma valve implantation for different types of glaucoma
    Furashova, Olga
    Pillunat, Karin
    Spoerl, Eberhard
    Pillunat, Lutz
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [35] Risk Factors for Choroidal Detachment After Ahmed Valve Implantation in Glaucoma Patients
    Shin, Da Young
    Jung, Kyoung In
    Park, Hae Young Lopilly
    Park, Chan Kee
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 211 : 105 - 113
  • [36] Evaluation of Diplopia Secondary to Seton Implantation Surgery: Ahmed Glaucoma Valve and Diplopia
    Taskoparan, Sariye
    Ocak, Osman Bulut
    Cakmak, Semih
    Pasaoglu, Isil Basgil
    Gokyigit, Birsen
    Solmaz, Banu
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2021, 51 (01): : 19 - 25
  • [37] Bilateral Ocular Decompression Retinopathy after Ahmed Valve Implantation for Uveitic Glaucoma
    Flores-Preciado, Javier
    Ancona-Lezama, David Arturo
    Valdes-Lara, Carlos Andres
    Diez-Cattini, Gian Franco
    Coloma-Gonzalez, Itziar
    CASE REPORTS IN OPHTHALMOLOGY, 2016, 7 (03): : 227 - 232
  • [38] Peritubular filtration as cause of severe hypotony after ahmed valve implantation for glaucoma
    García-Feijoó, J
    Cuiña-Sardiña, R
    Méndez-Fernández, C
    Castillo-Gómez, A
    García-Sánchez, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2001, 132 (04) : 571 - 572
  • [39] The role of primary needle revision after Ahmed glaucoma valve (AGV) implantation
    Maryam Yadgari
    Kiana Hassanpour
    Fatemeh Vafaei
    International Ophthalmology, 2021, 41 : 99 - 105
  • [40] Ahmed valve implantation to control intractable glaucoma after phacoemulsification and intraocular lens implantation in a dog
    García-Sánchez, GA
    Whitley, RD
    Brooks, DE
    Trigo, F
    Piñón, A
    VETERINARY OPHTHALMOLOGY, 2005, 8 (02) : 139 - 144