The use of positron emission particle tracking in the study of multiphase stirred tank reactor hydrodynamics

被引:0
|
作者
Fishwick, R
Winterbottom, M [1 ]
Parker, D
Fan, XF
Stitt, H
机构
[1] Univ Birmingham, Dept Chem Engn, Birmingham B15 2TT, W Midlands, England
[2] Univ Birmingham, Sch Phys & Astron, Birmingham B15 2TT, W Midlands, England
[3] Johnson Matthey Catalysts, Billingham TS23 1LB, Cleveland, England
来源
关键词
particle tracking; fluid trajectory; stirred tank reactor; hydrodynamics; PEPT;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper describes the use of positron emission particle Tracking (PEPT) in the analysis of local particle and fluid velocities in solid-liquid stirred tank reactors agitated with a Rushton turbine and an upward-pumping pitched blade turbine. PEPT captures the full three-dimensional characteristics of hydrodynamics and mixing in stirred vessels, allowing the analysis of the two-phase flow fields. Furthermore, by comparing the liquid and particle velocities, the spatial and temporal variation of the relative particle-liquid velocity can be estimated. Such information reveals considerable heterogeneity in the vessel and facilitates the evaluation of impeller design, particularly with the aim of minimizing mass transfer limitations.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 50 条
  • [21] EXPERIMENTAL STUDY OF MIXING + SEGREGATION IN STIRRED TANK REACTOR
    WORRELL, GR
    EAGLETON, LC
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1964, 42 (06): : 254 - &
  • [22] Computational Study of Hydrodynamics of a Standard Stirred Tank Reactor and a Large-Scale Multi-Impeller Fermenter
    Gunyol, O.
    Mudde, R. F.
    INTERNATIONAL JOURNAL FOR MULTISCALE COMPUTATIONAL ENGINEERING, 2009, 7 (06) : 559 - 576
  • [23] STUDY ON DYNAMIC BEHAVIOR OF STIRRED TANK REACTOR CASCADE
    PANNIER, R
    LIPPERT, S
    SCHNELLE, W
    CHEMISCHE TECHNIK, 1977, 29 (09): : 523 - 523
  • [24] Positron emission particle tracking using a modular positron camera
    Parker, D. J.
    Leadbeater, T. W.
    Fan, X.
    Hausard, M. N.
    Ingram, A.
    Yang, Z.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 339 - 342
  • [25] Positron emission particle tracking in pulsatile flow
    Patel, Nitant
    Wiggins, Cody
    Ruggles, Arthur
    EXPERIMENTS IN FLUIDS, 2017, 58 (05)
  • [26] Positron Emission Particle Tracking of Granular Flows
    Windows-Yule, C. R. K.
    Seville, J. P. K.
    Ingram, A.
    Parker, D. J.
    ANNUAL REVIEW OF CHEMICAL AND BIOMOLECULAR ENGINEERING, VOL 11, 2020, 11 : 367 - 396
  • [27] Positron emission particle tracking in pulsatile flow
    Nitant Patel
    Cody Wiggins
    Arthur Ruggles
    Experiments in Fluids, 2017, 58
  • [28] Study of the dispersion in rotary kilns using Positron Emission Particle Tracking
    desBoscs, JM
    Seville, JPK
    Parker, DJ
    Ferlin, P
    Bourlier, C
    1997 JUBILEE RESEARCH EVENT, VOLS 1 AND 2, 1997, : 533 - 536
  • [29] A case study of particle mixing in a ploughshare mixer using Positron Emission Particle Tracking
    Jones, JR
    Bridgwater, J
    INTERNATIONAL JOURNAL OF MINERAL PROCESSING, 1998, 53 (1-2) : 29 - 38
  • [30] Robust tracking control for the non-isothermal continuous stirred tank reactor
    Bzioui S.
    Channa R.
    Bzioui, Sana (bzioui.sana@gmail.com), 2020, Institute of Biophysics and Biomedical Engineering (24) : 131 - 142