Incidence and Predictors of Permanent Pacemaker Requirement after Transcatheter Aortic Valve Implantation with a Self-Expanding Bioprosthesis

被引:55
|
作者
Ferreira, Nuno Dias [1 ]
Caeiro, Daniel [1 ]
Adao, Luis [1 ]
Oliveira, Marco [1 ]
Goncalves, Helena [1 ]
Ribeiro, Jose [1 ]
Teixeira, Madalena [1 ]
Albuquerque, Anibal [1 ]
Primo, Joao [1 ]
Braga, Pedro [1 ]
Simoes, Lino [1 ]
Ribeiro, Vasco Gama [1 ]
机构
[1] Ctr Hosp Vila Nova de Gaia Espinho, Dept Cardiol, P-4434502 Vila Nova De Gaia, Portugal
来源
关键词
aortic stenosis; transcatheter aortic valve implantation; permanent pacemaker; PROGNOSTIC-SIGNIFICANCE; RISK-FACTORS; FOLLOW-UP; REPLACEMENT; STENOSIS; PROSTHESIS; EXPERIENCE; ANATOMY; BLOCK;
D O I
10.1111/j.1540-8159.2010.02870.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods: From August 2007 to October 2009, 32 consecutive patients underwent TAVI with the Medtronic CoreValve (MCV) System (Medtronic Inc., Minneapolis, MN, USA). Three patients paced at baseline and two cases of procedure-related mortality were excluded. We analyzed the 12-lead electrocardiogram at baseline, immediately after procedure and at discharge. Requirements for PPM were documented and potential clinical, electrophysiological, echocardiographic, and procedural predictors of PPM requirement were studied. Results: After TAVI, eight patients (29.6%) required PPM implantation due to high-grade atrioventricular (AV) block. The prevalence of left bundle branch block increased from 13.8% to 57.7% directly after implantation (P = 0.001). Need for PPM was correlated to the depth of prosthesis implantation (r = 0.590; P = 0.001). At a cutoff point of 10.1 mm, the likelihood of pacemaker could be predicted with 87.5% sensitivity and 74% specificity and a receiver operator characteristic curve area of 0.86 +/- 0.07 (P = 0.003). Of the seven patients with preexisting right bundle branch block (RBBB), four (57.1%) required PPM implantation after TAVI. Conclusions: High-grade AV block requiring PPM implantation is a common complication following TAVI and could be predicted by a deeper implantation of the prosthesis. Patients with preexisting RBBB also seem to be at risk for the development of high-grade AV block and subsequent pacemaker implantation. (PACE 2010; 1364-1372).
引用
收藏
页码:1364 / 1372
页数:9
相关论文
共 50 条
  • [41] Calcification of aortic valve cusps as independent predictor for permanent pacemaker requirement after transcatheter aortic valve implantation
    Jung, S.
    Ammon, F.
    Smolka, S.
    Moshage, M.
    Marwan, M.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [42] Rate and Predictors of Permanent Pacemaker Implantation after Transcatheter Aortic Valve Implantation: Current Status
    Russo, Elconora
    Potenza, Domenico R.
    Casclla, Michela
    Massaro, Raimondo
    Russo, Giulio
    Braccio, Maurizio
    Dello Russo, Antonio
    Cassese, Mauro
    CURRENT CARDIOLOGY REVIEWS, 2019, 15 (03) : 205 - 218
  • [43] Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with the Medtronic CoreValve system
    Fateh-Moghadam, S.
    Pachelhofer, A.
    Steeg, M.
    Doernberger, V.
    Gawaz, M.
    Bocksch, W.
    EUROPEAN HEART JOURNAL, 2014, 35 : 412 - 412
  • [44] Incidence and Predictors of Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Implantation: Analysis from the German Transcatheter Aortic Valve Interventions Registry
    Ledwoch, Jakob
    Franke, Jennifer
    Gerckens, Ulrich
    Kuck, Karl-Heinz
    Linke, Axel
    Nickenig, Georg
    Kruells-Muench, Juergen
    Voehringer, Matthias
    Hambrecht, Rainer
    Erbel, Raimund
    Richardt, Gert
    Horack, Martin
    Zahn, Ralf
    Senges, Jochen
    Sievert, Horst
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (04) : E569 - E577
  • [45] Infolding of a self-expanding bioprosthesis due to loss of nitinol memory during transcatheter aortic valve implantation
    Vasu, Nandhakumar
    Chopra, Aashish
    Rao, Ravinder Singh
    Ajit, Mullasari S.
    EUROINTERVENTION, 2020, 16 (04) : E301 - E302
  • [46] Self-expanding transcatheter aortic valve implantation for degenerated small Mitroflow bioprosthesis: early and midterm outcomes
    Adamo, Marianna
    Fiorina, Claudio
    Curello, Salvatore
    Chizzola, Giuliano
    Pezzotti, Elena
    Gavazzi, Emanuele
    Branca, Luca
    Chiari, Ermanna
    Quinzani, Filippo
    Rinaldi, Michele
    Metra, Marco
    Ettori, Federica
    EUROINTERVENTION, 2017, 13 (09) : 1032 - 1039
  • [47] Incidence and Electrocardiographic Predictors of Atrioventricular Conduction Recovery After Permanent Pacemaker Implantation in Transcatheter Aortic Valve Replacement
    Feng, Zekun
    Choy, Ho-hin
    Shin, Soomin
    Vu, Andrew
    Schricker, Amir
    Hongo, Richard
    Daniels, David
    Woods, Christopher E.
    CIRCULATION, 2022, 146
  • [48] Electrocardiographic and further predictors for permanent pacemaker requirements after transcatheter aortic valve implantation
    Nuis, Rutger-Jan
    de Jaegere, Peter
    EUROPACE, 2010, 12 (08): : 1061 - 1062
  • [49] Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3
    Mauri, Victor
    Reimann, Andreas
    Stern, Daniel
    Scherner, Maximilian
    Kuhn, Elmar
    Rudolph, Volker
    Rosenkranz, Stephan
    Eghbalzadeh, Kaveh
    Friedrichs, Kai
    Wahlers, Thorsten
    Baldus, Stephan
    Madershahian, Navid
    Rudolph, Tanja K.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (21) : 2200 - 2209
  • [50] Reinterventions After Transcatheter Aortic Valve Replacement With a Supra-Annular Self-Expanding Bioprosthesis
    Grubb, Kendra
    Lisko, John
    O'Hair, Daniel
    Merhi, William
    Heiser, John
    Chetcuti, Stanley
    Deeb, G.
    Kleiman, Neal
    Reardon, Michael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B195 - B195