Two-dimensional UTE overview imaging for dental application

被引:13
|
作者
Stumpf, Kilian [1 ]
Kaye, Elena [2 ]
Paul, Jan [1 ,3 ]
Wundrak, Stefan [1 ,3 ]
Pauly, John M. [4 ]
Rasche, Volker [1 ]
机构
[1] Ulm Univ, Med Ctr, Dept Internal Med 2, Albert Einstein Allee 23, D-89081 Ulm, Germany
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[3] Dentsply Sirona, Dent Imaging, Bensheim, Germany
[4] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
2D UTE; caries; dental imaging; half-pulse; tune delay; EDDY CURRENTS; MRI; COMPONENTS; TEETH; BONE;
D O I
10.1002/mrm.28312
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To investigate the applicability of a 2D-UTE half-pulse sequence for dental overview imaging and the detection of signal from mineralized dental tissue and caries lesions with ultra-short T2* as an efficient alternative to 3D sequences. Methods A modified 2D-UTE sequence using 240-mu s half-pulses for excitation and a reduction of the coil tune delay from the manufacturer preset value allowed for the acquisition of in vivo dental images with a TE of 35 mu s at 1.5T. The common occurrence of out-of-slice signal for half-pulse sequences was avoided by applying a quadratic-phase saturation pulse before each half-RF excitation. A conventional 2D-UTE sequence with a TE of 750 mu s, using slice selection rephasing, was used for comparison. Results Quadratic phase saturation pulses adequately improve the slice profile of half-pulse excitations for dental imaging with a surface coil. In vivo images and SNR measurements show a distinct increase in signal in ultrashort T2* tissues for the proposed 2D-UTE half-pulse sequence compared with a 2D-UTE sequence using conventional slice selection, leading to an improved detection of caries lesions. Conclusion The proposed pulse sequence enables the acquisition of in vivo images of a comprehensive overview of bone structures and teeth of a single side of the upper and lower jaw and signal detection from mineralized dental tissues in clinically acceptable scan times.
引用
收藏
页码:2616 / 2624
页数:9
相关论文
共 50 条
  • [31] TOMOGRAPHIC TWO-DIMENSIONAL PULSED DOPPLER IMAGING
    SCHMOLKE, J
    ERMERT, H
    ULTRASONIC IMAGING, 1987, 9 (01) : 46 - 46
  • [32] Photoplethysmographic Imaging of Hemodynamics and Two-Dimensional Oximetry
    Volkov, I. Yu.
    Sagaidachnyi, A. A.
    Fomin, A. V.
    OPTICS AND SPECTROSCOPY, 2022, 130 (07) : 452 - 469
  • [33] Nonlinear optical imaging of two-dimensional nanomaterials
    Sousa, Frederico B.
    Lafeta, Lucas
    Fonseca, Gladystone R.
    de Paula, Ana M.
    FRONTIERS IN NANOTECHNOLOGY, 2025, 7
  • [34] Subsurface imaging of two-dimensional materials at the nanoscale
    Dinelli, Franco
    Pingue, Pasqualantonio
    Kay, Nicholas D.
    Kolosov, Oleg V.
    NANOTECHNOLOGY, 2017, 28 (08)
  • [35] Intravascular two-dimensional tissue strain imaging
    Saijo, Yoshifumi
    Tanaka, Akira
    Iwamoto, Takahiro
    dos Santos Filho, Esmeraldo
    Yoshizawa, Makoto
    Hirosaka, Akira
    Kijima, Mikihiro
    Akino, Yoshihisa
    Hanadate, Yasushi
    Yambe, Tomoyuki
    ULTRASONICS, 2006, 44 (e147-e151) : E147 - E151
  • [36] Feasibility of two-dimensional quantitative sonoelastographic Imaging
    Hoyt, Kenneth
    Castaneda, Benjamin
    Parker, Kevin J.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2032 - 2035
  • [37] Imaging two-dimensional generalized Wigner crystals
    Hongyuan Li
    Shaowei Li
    Emma C. Regan
    Danqing Wang
    Wenyu Zhao
    Salman Kahn
    Kentaro Yumigeta
    Mark Blei
    Takashi Taniguchi
    Kenji Watanabe
    Sefaattin Tongay
    Alex Zettl
    Michael F. Crommie
    Feng Wang
    Nature, 2021, 597 : 650 - 654
  • [38] Electron capture imaging of two-dimensional materials
    Labaigt, G.
    Dubois, A.
    Hansen, J. P.
    PHYSICAL REVIEW B, 2014, 89 (24)
  • [39] Imaging grain boundaries in a two-dimensional polymer
    Victoria Richards
    Communications Chemistry, 3
  • [40] Interferometric two-dimensional imaging of rotating objects
    Aleksoff, C.
    OPTICS LETTERS, 1977, 1 (02) : 54 - 55