Concentrated stress effects of contoured and non-contoured high Tibial osteotomy plates: A finite-element study

被引:4
|
作者
Weng, Pei-Wei [1 ,2 ,3 ]
Liaw, Chen-Kun [1 ,2 ]
Chen, Chia-Hsien [1 ,2 ,3 ]
Luo, Chu-An [4 ]
Chen, Chih-Hwa [1 ,2 ,3 ]
Tsuang, Yang-Hwei [2 ]
Lin, Shang-Chih [4 ]
机构
[1] Taipei Med Univ, Coll Med, Sch Med, Dept Orthopaed, Taipei, Taiwan
[2] Taipei Med Univ, Shuang Ho Hosp, Dept Orthopaed, New Taipei, Taiwan
[3] Taipei Med Univ, Coll Biomed Engn, Grad Inst Biomed Mat & Tissue Engn, Taipei, Taiwan
[4] Natl Taiwan Univ Sci & Technol, Grad Inst Biomed Engn, 43 Keelung Rd,Sect 4, Taipei 10607, Taiwan
关键词
High tibial osteotomy; TomoFix plate; Contoured plate; Concentrated stress; Distal pain; WEDGE; COMPLICATIONS;
D O I
10.1016/j.clinbiomech.2020.105089
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The TomoFix plate has been extensively used in high tibial osteotomy surgery to stabilize the distracted tibial bones. However, distal pain related to plate irritation was considered one of the most relevant complications for this fixation device. This study aimed to correlate reports of distal pain with the profiles of the distracted tibia and initial plate and plate contour. Methods: This study used the finite-element method to investigate the profile-, distraction-, and contour-induced effects on stress distribution of the distal tibia-plate contact. The associations of two tibia profiles (normal and concave), distraction angles, and two plate profiles (contoured and non-contoured) were discussed in this study. The areas and stresses of the distal tibia-plate contact were chosen as comparison indices. Findings: Before weight-bearing, the non-contoured plates of the normal and concave tibia profiles consistently showed less contact area at the distal tibia-plate region. Consequently, the physiological loads make the non-contoured plate subject to more concentrated bone stresses and thus may induce more pain at the distal tibiaplate region than a contoured plate. When the distraction angle decreases, the tibia-plate gap increases. Prior to fixation, the tibia-plate gap can be evaluated by the profiles of the distracted tibia and non-contoured plate by use of anteroposterior radiograph and computer-aided simulation. Interpretation: In the situations of a lower distraction angle or a large tibia-plate gap, the use of a plate bender or a lag screw is recommended in order to contour the plate for reducing the concentrated stress at the distal tibia-plate region.
引用
收藏
页数:7
相关论文
共 29 条
  • [21] A FINITE-ELEMENT STUDY OF THE EFFECTS OF CONNECTOR SPACING AND DISTRIBUTION ON THE INITIAL BUCKLING STRESS OF A TWIN-CELLED BOX COLUMN
    TILLMAN, SC
    THIN-WALLED STRUCTURES, 1995, 22 (01) : 1 - 7
  • [22] A STUDY OF STRESS-DISTRIBUTION IN MODEL COMPOSITES BY FINITE-ELEMENT ANALYSIS .2. FIBER MATRIX INTERFACIAL EFFECTS
    FAN, CF
    HSU, SL
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 1992, 30 (06) : 619 - 635
  • [23] Stress and stability of newly designed medial anatomic locking plates and traditional fixations in the treatment of posterointernal tibial plateau fracture: a comparative finite element study
    Chen, Fancheng
    Wu, Silin
    Zhong, Zeyuan
    Huang, Xiaowei
    Ao, Rongguang
    Zhang, Xv
    Li, Dejian
    Qian, Zhi
    Zhang, Xiaobiao
    Yu, Baoqing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (12): : 12956 - 12963
  • [24] Study on the effects of hydrodynamic pressure on the dynamic stresses in slabs of high CFRD based on the scaled boundary finite-element method
    Xu, He
    Zou, Degao
    Kong, Xianjing
    Hu, Zhiqiang
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2016, 88 : 223 - 236
  • [25] Effects of conform, non-conform, and hybrid conformity toward stress distribution at the glenoid implant and cement: A finite element study
    Abdul Wahab, Abdul Hadi
    Mohamad Azmi, Nor Aqilah
    Abdul Kadir, Mohammed Rafiq
    Md Saad, Amir Putra
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2022, 45 (02): : 200 - 206
  • [26] Reductions in the effects of damping on stress concentration in premolars by post-endodontic restorations: a non-linear finite element study
    Lo, Y-J
    Chang, W-J
    Lee, S-Y
    Chang, K-J
    Lin, C-T
    Huang, H-M
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H5) : 555 - 565
  • [27] Study of stress development in axi-symmetric products processed by radial forging using a 3-D non-linear finite-element method
    Seoul Natl Polytechnic Univ, Seoul, Korea, Republic of
    J Mater Process Technol, 1-3 (74-82):
  • [28] Study of stress development in axi-symmetric products processed by radial forging using a 3-D non-linear finite-element method
    Jang, DY
    Liou, JH
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 1998, 74 (1-3) : 74 - 82
  • [29] Effects of Class II activator and Class II activator high-pull headgear combination on the mandible: A 3-dimensional finite element stress analysis study
    Ulusoy, Cagri
    Darendeliler, Niluefer
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (04) : 490.e9 - 490.e15