Concentrated stress effects of contoured and non-contoured high Tibial osteotomy plates: A finite-element study

被引:4
|
作者
Weng, Pei-Wei [1 ,2 ,3 ]
Liaw, Chen-Kun [1 ,2 ]
Chen, Chia-Hsien [1 ,2 ,3 ]
Luo, Chu-An [4 ]
Chen, Chih-Hwa [1 ,2 ,3 ]
Tsuang, Yang-Hwei [2 ]
Lin, Shang-Chih [4 ]
机构
[1] Taipei Med Univ, Coll Med, Sch Med, Dept Orthopaed, Taipei, Taiwan
[2] Taipei Med Univ, Shuang Ho Hosp, Dept Orthopaed, New Taipei, Taiwan
[3] Taipei Med Univ, Coll Biomed Engn, Grad Inst Biomed Mat & Tissue Engn, Taipei, Taiwan
[4] Natl Taiwan Univ Sci & Technol, Grad Inst Biomed Engn, 43 Keelung Rd,Sect 4, Taipei 10607, Taiwan
关键词
High tibial osteotomy; TomoFix plate; Contoured plate; Concentrated stress; Distal pain; WEDGE; COMPLICATIONS;
D O I
10.1016/j.clinbiomech.2020.105089
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The TomoFix plate has been extensively used in high tibial osteotomy surgery to stabilize the distracted tibial bones. However, distal pain related to plate irritation was considered one of the most relevant complications for this fixation device. This study aimed to correlate reports of distal pain with the profiles of the distracted tibia and initial plate and plate contour. Methods: This study used the finite-element method to investigate the profile-, distraction-, and contour-induced effects on stress distribution of the distal tibia-plate contact. The associations of two tibia profiles (normal and concave), distraction angles, and two plate profiles (contoured and non-contoured) were discussed in this study. The areas and stresses of the distal tibia-plate contact were chosen as comparison indices. Findings: Before weight-bearing, the non-contoured plates of the normal and concave tibia profiles consistently showed less contact area at the distal tibia-plate region. Consequently, the physiological loads make the non-contoured plate subject to more concentrated bone stresses and thus may induce more pain at the distal tibiaplate region than a contoured plate. When the distraction angle decreases, the tibia-plate gap increases. Prior to fixation, the tibia-plate gap can be evaluated by the profiles of the distracted tibia and non-contoured plate by use of anteroposterior radiograph and computer-aided simulation. Interpretation: In the situations of a lower distraction angle or a large tibia-plate gap, the use of a plate bender or a lag screw is recommended in order to contour the plate for reducing the concentrated stress at the distal tibia-plate region.
引用
收藏
页数:7
相关论文
共 29 条
  • [1] Effects of pre-contoured and in situ contoured rods on the mechanical strength and durability of posterior cervical instrumentation: a finite-element analysis and scanning electron microscopy investigation
    Kim, Kee D.
    Panchal, Ripul
    Moldavsky, Mark
    Wang, Wenhai
    Bucklen, Brandon S.
    SPINE DEFORMITY, 2020, 8 (04) : 569 - 576
  • [2] Effects of pre-contoured and in situ contoured rods on the mechanical strength and durability of posterior cervical instrumentation: a finite-element analysis and scanning electron microscopy investigation
    Kee D. Kim
    Ripul Panchal
    Mark Moldavsky
    Wenhai Wang
    Brandon S. Bucklen
    Spine Deformity, 2020, 8 : 569 - 576
  • [3] Static and fatigue strength of a novel anatomically contoured implant compared to five current open-wedge high tibial osteotomy plates
    Diffo Kaze A.
    Maas S.
    Belsey J.
    Hoffmann A.
    Pape D.
    Journal of Experimental Orthopaedics, 4 (1)
  • [4] Finite element analysis of the high frequency vibrations of contoured crystal plates with higher-order plate theory
    Wang, J
    Yong, YK
    Imai, T
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1998, : 909 - 914
  • [5] Design optimization of high tibial osteotomy plates using finite element analysis for improved biomechanical effect
    Koh, Yong-Gon
    Lee, Jin-Ah
    Lee, Hwa-Yong
    Chun, Heoung-Jae
    Kim, Hyo-Jeong
    Kang, Kyoung-Tak
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [6] Design optimization of high tibial osteotomy plates using finite element analysis for improved biomechanical effect
    Yong-Gon Koh
    Jin-Ah Lee
    Hwa-Yong Lee
    Heoung-Jae Chun
    Hyo-Jeong Kim
    Kyoung-Tak Kang
    Journal of Orthopaedic Surgery and Research, 14
  • [7] Effects of plate contouring quality on the biomechanical performance of high tibial osteotomy fixation: A parametric finite element study
    Hayatbakhsh, Zahra
    Farahmand, Farzam
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (03) : 356 - 366
  • [8] Biomechanical evaluation of opening-wedge high tibial osteotomy with composite materials using finite-element analysis
    Koh, Yong-Gon
    Son, Juhyun
    Kwon, Sae Kwang
    Kim, Hyo Jeong
    Kang, Kyoung-Tak
    KNEE, 2018, 25 (06): : 977 - 987
  • [9] MECHANICAL-STRESS DISTRIBUTION IN THE TIBIAL BONE IN TOTAL KNEE REPLACEMENT - A FINITE-ELEMENT STUDY
    JANSSON, V
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1991, 129 (05): : 389 - 392
  • [10] Analysis of Stress Distribution on Fixation of Bilateral Sagittal Split Ramus Osteotomy With Resorbable Plates and Screws Using the Finite-Element Method
    Sarkarat, Farzin
    Motamedi, Mohammad Hosein Kalantar
    Bohluli, Behnam
    Moharamnejad, Nima
    Ansari, Shirin
    Shahabi-Sirjani, Hale
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (06) : 1434 - 1438