Effects of panel zone yielding on seismic behavior of welded-flange-plate connections

被引:12
|
作者
Kosarieh, Amir Homayoon [1 ]
Danesh, Fakhreddin [1 ]
机构
[1] KN Toosi Univ Technol, Fac Civil Engn, Mirdamad Intersect, 1346 Vali Asr St,POB 15875-4416, Tehran 1996715433, Iran
关键词
Welded-flange-plate; Connection; Panel zone yielding; Plastic rotation; Seismic behavior; Energy dissipation; MOMENT CONNECTIONS; JOINT-PANEL; TESTS;
D O I
10.1007/s10518-016-9915-6
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In this study, effects of panel zone yielding on the seismic performance of welded-flange-plate (WFP) connections are investigated. In this work, four full-scale beam-to-column connections were used to run the experiments under cyclic loading. The obtained results can potentially lead to a better understanding of the influence of the panel zone inelastic shear deformation on the cyclic behavior of WFP connections for external joints in steel moment resisting frames (SMRFs). The main parameter in the testing program was the panel zone strength having a wide variation to gain the different levels of panel zone yielding. Results showed that all specimens had a high connection rotation capacity to satisfy the requirements of special moment frame connections. However, specimens with different panel zone strengths could provide the different amount of energy dissipation. Severe beam buckling was followed by tearing along the k-line region of the beam in the plastic hinge location, as well as tearing of the beam at the nose of the bottom flange plates which were both observed as a predominant failure mode in the specimens with a stronger panel zone. However, specimens with weak panel zone could develop a significant plastic rotation without causing any major problem to the beam-to-column connection groove welds. Based on mentioned observations and considering the effect of panel zone yielding because of different panel zone strengths on the hysteresis behavior of specimens, failure modes, plastic rotation capacity, and energy dissipation, some modifications were proposed for design requirements of the panel zone strength.
引用
收藏
页码:2805 / 2825
页数:21
相关论文
共 50 条
  • [21] Seismic Enhancement of Welded Unreinforced Flange-Bolted Web Steel Moment Connections
    Morrison, Machel Leigh
    Schweizer, Douglas Quinn
    Hassan, Tasnim
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (11)
  • [22] Performance evaluation of curved welded flange-plate beam-to-column connections
    Ghafari, Y.
    Mofid, M.
    Sedehi, O.
    SCIENTIA IRANICA, 2016, 23 (06) : 2494 - 2505
  • [23] The Effect of Plastic Hinge Location on the Flexural Strength Demand of Welded Flange Plate Connections
    Hsiao, J. Kent
    Shrestha, Santosh
    Vootukuri, Venkat Ramana Reddy
    Mensah, Frederick
    Electronic Journal of Structural Engineering, 2019, 19 (01): : 71 - 84
  • [24] The Effect of Plastic Hinge Location on the Flexural Strength Demand of Welded Flange Plate Connections
    Hsiao, J. Kent
    Shrestha, Santosh
    Vootukuri, Venkat Ramana Reddy
    Mensah, Frederick
    ELECTRONIC JOURNAL OF STRUCTURAL ENGINEERING, 2019, 19 : 71 - 84
  • [25] Seismic performance of flange plate connections between steel beams and box columns
    Gholami, M.
    Deylami, A.
    Tehranizadeh, M.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 84 : 36 - 48
  • [26] Mechanical and seismic behaviors of bottom-flange-bolted upper-flange-welded through-diaphragm connections
    Yu, Yujie
    Lan, Lifeng
    Chen, Zhihua
    Huang, Jun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 156 : 86 - 95
  • [27] A new detail for the panel zone of beam-to-wide flange column connections with endplate
    Solhmirzaei, Arash
    Roudsari, Mehrzad Tahamouli
    Hashemi, Behrokh Hosseini
    STRUCTURES, 2021, 34 : 1108 - 1123
  • [28] Seismic behaviour of high-strength steel welded flange-bolted web connections
    Hu, Fangxin
    Wang, Zhan
    ce/papers, 2023, 6 (3-4) : 650 - 654
  • [29] The Importance of Panel Zone Shear Strength on Seismic Behavior of Improved Slotted-web Beam Connections
    Adlparvar, Mohammad Reza
    Vetr, Mohammad Ghasem
    Ghaffari, Farshad
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2017, 17 (01) : 307 - 318
  • [30] The importance of panel zone shear strength on seismic behavior of improved slotted-web beam connections
    Mohammad Reza Adlparvar
    Mohammad Ghasem Vetr
    Farshad Ghaffari
    International Journal of Steel Structures, 2017, 17 : 307 - 318