Effects of panel zone yielding on seismic behavior of welded-flange-plate connections

被引:12
|
作者
Kosarieh, Amir Homayoon [1 ]
Danesh, Fakhreddin [1 ]
机构
[1] KN Toosi Univ Technol, Fac Civil Engn, Mirdamad Intersect, 1346 Vali Asr St,POB 15875-4416, Tehran 1996715433, Iran
关键词
Welded-flange-plate; Connection; Panel zone yielding; Plastic rotation; Seismic behavior; Energy dissipation; MOMENT CONNECTIONS; JOINT-PANEL; TESTS;
D O I
10.1007/s10518-016-9915-6
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
In this study, effects of panel zone yielding on the seismic performance of welded-flange-plate (WFP) connections are investigated. In this work, four full-scale beam-to-column connections were used to run the experiments under cyclic loading. The obtained results can potentially lead to a better understanding of the influence of the panel zone inelastic shear deformation on the cyclic behavior of WFP connections for external joints in steel moment resisting frames (SMRFs). The main parameter in the testing program was the panel zone strength having a wide variation to gain the different levels of panel zone yielding. Results showed that all specimens had a high connection rotation capacity to satisfy the requirements of special moment frame connections. However, specimens with different panel zone strengths could provide the different amount of energy dissipation. Severe beam buckling was followed by tearing along the k-line region of the beam in the plastic hinge location, as well as tearing of the beam at the nose of the bottom flange plates which were both observed as a predominant failure mode in the specimens with a stronger panel zone. However, specimens with weak panel zone could develop a significant plastic rotation without causing any major problem to the beam-to-column connection groove welds. Based on mentioned observations and considering the effect of panel zone yielding because of different panel zone strengths on the hysteresis behavior of specimens, failure modes, plastic rotation capacity, and energy dissipation, some modifications were proposed for design requirements of the panel zone strength.
引用
收藏
页码:2805 / 2825
页数:21
相关论文
共 50 条
  • [1] Effects of panel zone yielding on seismic behavior of welded-flange-plate connections
    Amir Homayoon Kosarieh
    Fakhreddin Danesh
    Bulletin of Earthquake Engineering, 2016, 14 : 2805 - 2825
  • [2] Column Axial Load Effects on Performance of Panel Zone in Welded-Flange-Plate Connections
    Kosarieh, Amir Homayoon
    Danesh, Fakhreddin
    Shiri, Ramin
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (06) : 775 - 789
  • [3] Seismic performance of welded flange plate (WFP) connections in composite steel structures
    Masoudi, Mohammad Javad
    Broumand, Pooyan
    Journal of Constructional Steel Research, 2022, 189
  • [4] Seismic performance of welded flange plate (WFP) connections in composite steel structures
    Masoudi, Mohammad Javad
    Broumand, Pooyan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 189
  • [5] Computation of story drifts considering panel zone deformations for multistory steel moment frames with welded flange plate connections
    Hsiao, J. Kent
    Schultz, William
    Petersen, Troy
    Vaicik, Stephen
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2008, 17 (02): : 419 - 443
  • [6] Cyclic behavior and seismic design of bolted flange plate steel moment connections
    Sato, Atsushi
    Newell, James D.
    Uang, Chia-Ming
    Engineering Journal, 1600, 45 (04): : 221 - 232
  • [7] Panel zone yielding in steel moment connections
    El-Tawil, S
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 2000, 37 (03): : 120 - 131
  • [8] Panel zone yielding in steel moment connections
    El-Tawil, Sherif
    Engineering Journal, 2000, 37 (03): : 120 - 131
  • [9] Cyclic Behavior and Seismic Design of Bolted Flange Plate Steel Moment Connections
    Sato, Atsushi
    Newell, James D.
    Uang, Chia-Ming
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 2008, 45 (04): : 221 - 232
  • [10] Mechanical behavior of bolted beam-to-column connections with panel zone yielding
    Suita, K
    Inoue, K
    Kanoh, N
    STESSA 2003: BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2003, : 363 - 368