Dose verification for respiratory-gated volumetric modulated arc therapy

被引:36
|
作者
Qian, Jianguo [1 ]
Xing, Lei [1 ]
Liu, Wu [1 ]
Luxton, Gary [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 15期
关键词
ION-CHAMBER ARRAY; CONE-BEAM CT; QUALITY-ASSURANCE; PHOTON BEAMS; DELIVERY; RADIOTHERAPY; IMRT; RECONSTRUCTION;
D O I
10.1088/0031-9155/56/15/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A novel commercial medical linac system (TrueBeam (TM), Varian Medical Systems, Palo Alto, CA) allows respiratory-gated volumetric modulated arc therapy (VMAT), a new modality for treating moving tumors with high precision and improved accuracy by allowing for regular motion associated with a patient's breathing during VMAT delivery. The purpose of this work is to adapt a previously-developed dose reconstruction technique to evaluate the fidelity of VMAT treatment during gated delivery under clinic-relevant periodic motion related to patient breathing. A Varian TrueBeam system was used in this study. VMAT plans were created for three patients with lung or pancreas tumors. Conventional 6 and 15 MV beams with flattening filter and high-dose-rate 10 MV beams with no flattening filter were used in these plans. Each patient plan was delivered to a phantom first without gating and then with gating for three simulated respiratory periods (3, 4.5 and 6 s). Using the adapted log-file-based dose reconstruction procedure supplemented with ion chamber array (Seven29 (TM), PTW, Freiburg, Germany) measurements, the delivered dose was used to evaluate the fidelity of gated VMAT delivery. Comparison of Seven29 measurements with and without gating showed good agreement with gamma-index passing rates above 99% for 1%/1 mm dose accuracy/distance-to-agreement criteria. With original plans as reference, gamma-index passing rates were 100% for the reconstituted plans (1%/1 mm criteria) and 93.5-100% for gated Seven29 measurements (3%/3 mm criteria). In the presence of leaf error deliberately introduced into the gated delivery of a pancreas patient plan, both dose reconstruction and Seven29 measurement consistently indicated substantial dosimetric differences from the original plan. In summary, a dose reconstruction procedure was demonstrated for evaluating the accuracy of respiratory-gated VMAT delivery. This technique showed that under clinical operation, the TrueBeam system faithfully realized treatment plans with gated delivery. This methodology affords a useful tool for machine- and patient-specific quality assurance of the newly available respiratory-gated VMAT.
引用
收藏
页码:4827 / 4838
页数:12
相关论文
共 50 条
  • [21] Verification of Volumetric Modulated Arc Therapy Plans with Independent Three Dimensional Dose Computation Algorithm
    Kathirvel, M.
    Subramanian, V. Shanmuga
    Arun, G.
    Swamy, S. Thirumalai
    Ramalingam, K.
    Kala, S.
    Kumar, S. Ashok
    Anantharaman, A.
    Karthikeyan, K.
    Kumar, N. Jagdish
    Arivarasan, I.
    Babaiah, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [22] Dose verification of volumetric modulated arc therapy (VMAT) by use of in-treatment linac parameters
    Haga A.
    Sakumi A.
    Okano Y.
    Itoh S.
    Saotome N.
    Kida S.
    Igaki H.
    Shiraishi K.
    Yamashita H.
    Ohtomo K.
    Nakagawa K.
    [J]. Radiological Physics and Technology, 2013, 6 (2) : 335 - 342
  • [23] Verification of dose distribution for volumetric modulated arc therapy total marrow irradiation in a humanlike phantom
    Surucu, Murat
    Yeginer, Mete
    Kavak, Gulbin O.
    Fan, John
    Radosevich, James A.
    Aydogan, Bulent
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 281 - 288
  • [24] Verification of Geometric Parameters in Volumetric Modulated Arc Therapy (VMAT)
    Qian, J.
    Lee, L.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [25] Dosimetric Verification for Volumetric Modulated Arc Therapy (VMAT) with Gating
    Qian, J.
    Xing, L.
    Luxton, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [26] Delivery Efficiency and Dosimetric Accuracy of Respiratory Gated Volumetric Modulated Arc Therapy Using a Digital Accelerator
    Cui, G.
    Housley, D.
    Chen, F.
    Mehta, V. K.
    Shepard, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S855 - S855
  • [27] A Study on Gantry Position Accuracy Using Delivered Dose Distributions for Gated Volumetric Modulated Arc Therapy
    Ravindran, P.
    Balasingh, T.
    Raj, J.
    Woon, W.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E590 - E590
  • [28] Evaluation of delivered dose to a moving target by 4D dose reconstruction in gated volumetric modulated arc therapy
    Chung, Hyekyun
    Jung, Jinhong
    Jeong, Chiyoung
    Kwak, Jungwon
    Park, Jin-hong
    Kim, Su Ssan
    Yoon, Sang Min
    Song, Si Yeol
    Kim, Jong Hoon
    Choi, Eun Kyung
    Cho, Seungryong
    Cho, Byungchul
    [J]. PLOS ONE, 2018, 13 (09):
  • [29] Respiratory-gated proton therapy treatment
    Lu, H.
    Safai, S.
    Schneider, R.
    Adams, J.
    Chen, Y.
    Sharp, G.
    Brett, R.
    Kirsch, D.
    Hong, T.
    Delaney, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S618 - S619
  • [30] Dosimetric properties of respiratory-gated intensity modulated are treatments
    Wong, E
    Allanson, S
    Berryhill, G
    Chen, J
    Gaede, S
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1973 - 1973