Quantomo: validation of a computer-assisted methodology for the volumetric analysis of intracerebral haemorrhage

被引:74
|
作者
Kosior, Jayme C. [2 ,3 ]
Idris, Sherif [3 ]
Dowlatshahi, Dar [3 ,4 ]
Alzawahmah, Mohamed [3 ,4 ]
Eesa, Muneer [3 ,5 ]
Sharma, Pranshu [3 ,5 ]
Tymchuk, Sarah [3 ]
Hill, Michael D. [3 ,4 ,5 ,6 ,7 ]
Aviv, Richard I. [8 ]
Frayne, Richard [2 ,3 ,4 ,5 ]
Demchuk, Andrew M. [1 ,3 ,4 ,5 ,6 ]
机构
[1] Univ Calgary, Hotchkiss Brain Inst, Foothills Med Ctr, Dept Clin Neurosci & Radiol, Calgary, AB T2N 2T9, Canada
[2] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 2T9, Canada
[3] Calgary Hlth Reg, Foothills Med Ctr, Seaman Family MR Res Ctr, Calgary, AB, Canada
[4] Univ Calgary, Dept Clin Neurosci, Calgary, AB T2N 2T9, Canada
[5] Univ Calgary, Dept Radiol, Calgary, AB T2N 2T9, Canada
[6] Univ Calgary, Dept Med, Calgary, AB T2N 2T9, Canada
[7] Univ Calgary, Dept Community Hlth Sci, Calgary, AB T2N 2T9, Canada
[8] Sunnybrook Hlth Sci Ctr, Div Neuroradiol, Toronto, ON M4N 3M5, Canada
关键词
cerebral haemorrhage; CT scan; haemorrhage; methodology; radiology; stroke; ACTIVATED FACTOR-VII; CT-ANGIOGRAPHY; HEMATOMA EXPANSION; SPOT SIGN; PREDICTION;
D O I
10.1111/j.1747-4949.2010.00579.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Volume measurements of intracerebral haemorrhage are prognostically important and are increasingly used in clinical trials to measure the effects of potential interventions. The purpose of this work is to establish the reliability of haematoma volume measurements obtained using a computer-assisted method called Quantomo (for quantitative tomography) and the ABC/2 method. Hypothesis Quantomo reliably detects smaller changes in intracerebral haemorrhage volume as compared with the ABC/2 method because computer-assisted volume measurements are tailored to measure the geometry of individual haematoma volumes whereas the ABC/2 method approximates all haematoma volumes as ellipsoids. Methods Thirty randomly selected computed tomography scans with intracerebral haemorrhage were measured by four raters a total of four times each (two sessions using Quantomo and two using the ABC/2 method). Interrater and intrarater reliability for both techniques were calculated simultaneously using a two-way random-effects analysis of variance model. The precision of intracerebral haemorrhage volume measurement was quantified as the minimum detectable difference with 95% confidence intervals. Results The median (first quartile and third quartile) intracerebral haemorrhage volume measurements of all rater and sessions for Quantomo were 32.7 ml (6.2 and 54.4 ml) and for ABC/2 40.7 ml (8.6 and 76.0 ml). Quantomo intracerebral haemorrhage volume measurements were more precise, having an inter-and intrarater minimum detectable difference of 8.1 and 5.3 ml, while the inter-and intrarater minimum detectable difference for ABC/2 were 37.0 and 15.7 ml. Conclusions Quantomo is a computer-assisted methodology that is more reliable for quantifying intracerebral haemorrhage volume as compared with the ABC/2 method.
引用
收藏
页码:302 / 305
页数:4
相关论文
共 50 条
  • [41] COMPUTER-ASSISTED ANALYSIS OF FLAGELLAR STRUCTURE
    OTOOLE, E
    MASTRONARDE, D
    MCINTOSH, JR
    PORTER, ME
    METHODS IN CELL BIOLOGY, VOL 47, 1995, 47 : 183 - 191
  • [42] COMPUTER-ASSISTED ANALYSIS OF CHEMICAL EQUILIBRIUM
    NAGANO, K
    JAPAN ANALYST, 1970, 19 (08): : 1098 - &
  • [43] COMPUTER-ASSISTED TESTING AND ANALYSIS OF LOGISTICS
    ROELOGS, TB
    OPERATIONS RESEARCH, 1966, S 14 : B89 - &
  • [44] COMPUTER-ASSISTED ANALYSIS OF VISUAL PIGMENTS
    MUNZ, FW
    ALLEN, DM
    VISION RESEARCH, 1968, 8 (08) : 983 - &
  • [45] Foundations of computer-assisted data analysis
    不详
    PSYCHOLOGIE IN ERZIEHUNG UND UNTERRICHT, 1999, 46 (03): : 239 - 239
  • [46] COMPUTER-ASSISTED ANALYSIS OF FLUORESCEIN VIDEOANGIOGRAMS
    MEYER, PAR
    FITZKE, FW
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1990, 74 (05) : 275 - 277
  • [47] COMPUTER-ASSISTED ANALYSIS OF HOLTER RECORDINGS
    KLIGFIELD, P
    STEIN, KM
    HERROLD, EM
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1990, 601 : 353 - 369
  • [48] COMPUTER-ASSISTED ANALYSIS OF LEUKOEMBOLI FORMATION
    CHEUNG, ATW
    DONOVAN, RM
    WALSH, EM
    MILLER, ME
    CHEMICAL ENGINEERING COMMUNICATIONS, 1986, 47 (1-3) : 139 - 146
  • [49] THE COMPUTER-ASSISTED TARGET ANALYSIS SYSTEM
    PALUMBO, PA
    CONNOR, GJ
    POLICE CHIEF, 1983, 50 (05): : 67 - 70
  • [50] COMPUTER-ASSISTED LANGUAGE ANALYSIS WITH THE MACINTOSH
    GERVASIO, AH
    TAYLOR, J
    HIRSHFIELD, S
    BEHAVIOR RESEARCH METHODS INSTRUMENTS & COMPUTERS, 1992, 24 (02): : 298 - 302