Long-term Performance Evaluation and Economic Analysis for Deep Borehole Heat Exchanger Heating System in Weihe Basin

被引:14
|
作者
Cai, Wanlong [1 ]
Wang, Fenghao [1 ]
Jiang, Jinghua [1 ]
Wang, Zeyuan [1 ]
Liu, Jun [2 ,3 ]
Chen, Chaofan [4 ]
机构
[1] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian, Peoples R China
[2] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Util, Xian, Peoples R China
[3] Shaanxi Coal Geol Grp Co Ltd, Xian, Peoples R China
[4] UFZ Helmholtz Ctr Environm Res, Leipzig, Germany
关键词
deep borehole heat exchanger; heating system; heat extraction performance; economic analysis; Weihe Basin; OpenGeoSys; THERMAL PERFORMANCE; PUMP SYSTEMS; FIELD-TEST; SUSTAINABILITY; SIMULATION; EFFICIENCY; CAPACITY; TRENDS; MODEL; WELLS;
D O I
10.3389/feart.2022.806416
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
To reduce carbon emission and achieve carbon neutrality, deep geothermal energy has been widely extracted for building heating purpose. In recent years, deep borehole heat exchanger (DBHE) heating system has gained more attention, especially in densely populated urban areas in Weihe Basin, northern China. The long-term performance and the economic feasibility are essential for the system application. In this work, the DBHE model implemented in OpenGeoSys software is verified against an analytical solution and a comprehensive economic analysis approach is further proposed. Then the short-term thermal performance tests are conducted to obtain the tentative heat extraction capacity for long-term simulation. The long-term simulations are further performed with the heat pump unit under the adjusted tentative heat extraction rate imposed on the DBHE. Finally, a comprehensive economic analysis is applied to the DBHE heating system over 15 heating seasons. Results show that the minimum coefficient of performance value of the heat pump is 4.74 over the operation of 15 heating seasons. With the increase of depth for the DBHE, the total electricity consumption of heat pumps and circulation pumps has a prominent promotion. With the comprehensive approach of economic analysis, the depth of 2,600 m has the lowest levelized cost of total heating amount, which is the best system design for the application in Weihe Basin. The present results are specific to the conditions in Weihe Basin, but the proposed economic analysis approach is generic.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Numerical Study on the Long-Term Performance and Load Imbalance Ratio for Medium-Shallow Borehole Heat Exchanger System
    Wang, Ruifeng
    Wang, Fenghao
    Xue, Yuze
    Jiang, Jinghua
    Zhang, Yuping
    Cai, Wanlong
    Chen, Chaofan
    [J]. ENERGIES, 2022, 15 (09)
  • [32] Multi-faceted performance analysis and optimization of a hybrid deep borehole heat exchanger heating system with latent heat thermal energy storage
    Wang, Zeyuan
    Wang, Fenghao
    Bai, Mengmeng
    Zhang, Sheng
    Xie, Zhentao
    Han, Baocheng
    Li, Yizhen
    Liu, Jun
    Cai, Wanlong
    Zhang, Yixuan
    Ma, Zhenjun
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2024, 315
  • [33] Energetic Efficiency of a Deep Borehole Heat Exchanger Adapted from a Freezing Borehole Based on a Long-Term Thermal Response Test
    Sliwa, Tomasz
    Drosik, Jakub
    Kruszewski, Michal
    Assadi, Mohsen
    Kotyla, Stanislaw
    [J]. Energies, 2024, 17 (23)
  • [34] Long-term operation performance of moderately deep borehole heat exchangers in the Guanzhong area
    Zhang Z.
    Ma Z.
    Hao J.
    Jia G.
    Ke T.
    Cheng C.
    Jin L.
    [J]. Meitiandizhi Yu Kantan/Coal Geology and Exploration, 2024, 52 (01):
  • [35] Long-term performance of large borehole heat exchanger fields with unbalanced seasonal loads and groundwater flow
    Zanchini, Enzo
    Lazzari, Stefano
    Priarone, Antonella
    [J]. ENERGY, 2012, 38 (01) : 66 - 77
  • [36] Long-term performance of large borehole heat exchanger fields with unbalanced seasonal loads and groundwater flow
    Dipartimento di Ingegneria Energetica Nucleare e del Controllo Ambientale, Università di Bologna, Viale Risorgimento 2, I-40136 Bologna, Italy
    不详
    [J]. Energy, 1 (66-77):
  • [37] Long-term high frequency monitoring of a large borehole heat exchanger array
    Naicker, Selvaraj S.
    Rees, Simon J.
    [J]. RENEWABLE ENERGY, 2020, 145 : 1528 - 1542
  • [38] Study on long-term performance sustainability of medium deep borehole heat exchanger based on simplified one-dimensional well model
    Chen, Ke
    Zhang, Jinping
    Kong, Xiangjun
    Zheng, Jia
    Li, Juan
    Yuan, Lijuan
    Liu, Aihua
    Zhang, Qiulan
    [J]. APPLIED THERMAL ENGINEERING, 2023, 230
  • [39] Numerical Investigation of the Long-Term Load Shifting Behaviors within the Borehole Heat Exchanger Array System
    Zou, Haijiang
    Guo, Siyu
    Wang, Ruifeng
    Wang, Fenghao
    Shen, Zhenxing
    Cai, Wanlong
    [J]. ENERGIES, 2023, 16 (05)
  • [40] Performance analysis of deep borehole heat exchangers for decarbonization of heating systems
    Lund, Andreas E. D.
    [J]. DEEP UNDERGROUND SCIENCE AND ENGINEERING, 2024, : 349 - 357