Implementation of the global risk analysis in pulsed-dose rate brachytherapy: Methods and results

被引:2
|
作者
Mazeron, R. [1 ]
Aguini, N. [2 ]
del Campo, E. Rivin [1 ]
Dumas, I. [3 ]
Gensse, M. -C. [1 ]
Brusadin, G. [1 ]
Lefkopoulos, D. [3 ]
Deutsch, E. [1 ]
Haie-Meder, C. [1 ]
机构
[1] Gustave Roussy Canc Campus Grand Paris, Radiat Oncol, F-97805 Villejuif, France
[2] Gustave Roussy Canc Campus Grand Paris, Qual & Risk Assessment, F-97805 Villejuif, France
[3] Gustave Roussy Canc Campus Grand Paris, Med Phys, F-97805 Villejuif, France
来源
CANCER RADIOTHERAPIE | 2015年 / 19卷 / 02期
关键词
Pulsed-dose rate brachytherapy; Safety; Risk assessment; Global risk analysis; Mapping; RADIATION-THERAPY; FAILURE MODE; RADIOTHERAPY; TECHNOLOGIES; SAFETY; SYSTEM; CARE;
D O I
10.1016/j.canrad.2014.11.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose. - To report the application of the global risk analysis (GRA) in the pulsed-dose rate (PDR) brachytherapy workflow. Material and Methods. - Analyses were led by a multidisciplinary working group established within the unit with the guidance of a quality engineer. First, a mapping of hazardous situations was developed as a result of interactions between the patient workflow for a treatment using PDR brachytherapy split into 51 sub-phases with a comprehensive list of the hazards that he/she faces (44). Interactions, when relevant, were sorted by level of priority: to be treated immediately, secondarily (the group is not entitled to treat the situation), or later (safe situation). Secondly, for each high priority dangerous situation, scenarios were developed to anticipate their potential consequences. Criticality was assessed, using likelihood and severity scales and a matrix, which allocated risks into categories: acceptable (C1), tolerable under control (C2) and unacceptable (C3). Then, corrective actions were proposed and planned when relevant, after assessment of their feasibility with a scale of effort. Finally, the criticality of the scenarios was reevaluated, taking into account the implementation of these actions, leading to a residual risk mapping, which could trigger additional proposals of actions. Results. - Two thousand one hundred and eighty-four potential interactions between the list of hazards and the workflow were analyzed. Mapping of dangerous situations identified 213 relevant interactions, from which 61 were considered with high priority. One hundred and twenty-six scenarios were generated: 68 with a low criticality (74.3%), 58 with an intermediate score (25.7%). No scenario with the highest criticality was individualized. Twenty-one corrective actions were planned. Mapping of residual risk resulted in the disappearance of most C2 risks, leaving 5 C2 scenarios (4%), for which four monitoring indicators were implemented in addition to the corrected actions decided on. Conclusion. - The implementation of the GRA appeared feasible, and led to implement 21 corrective actions, based on scenarios and not on incidents. (C) 2015 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:89 / 97
页数:9
相关论文
共 50 条
  • [31] Dose rate and fractionation effects of pulsed dose rate brachytherapy in B-14 fibroblasts
    Keilholz, L
    Seegenschmiedt, MH
    ScholzWendtland, R
    Sauer, R
    RADIOLOGY, 1996, 201 : 800 - 800
  • [32] Pulsed low dose rate brachytherapy for uterine cervix carcinoma
    Rogers, CL
    Freel, JH
    Speiser, BL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (01): : 95 - 100
  • [33] Pulsed brachytherapy as a substitute for continuous low dose rate: Comment
    Fowler, JF
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (03): : 776 - 776
  • [34] Professional nursing aspects of pulsed dose rate (PDR) brachytherapy
    Andersen, C
    EUROPEAN JOURNAL OF CANCER, 1997, 33 : 1457 - 1457
  • [35] Clinical Outcomes and Dosimetric Analysis of a Prospective Trial utilizing MRI-guided Single-line Source Intracavitary Pulsed-Dose Rate Brachytherapy in Locally Advanced Cervical Cancer
    Walsh, L.
    Morgia, M.
    Xie, J.
    Jezioranski, J.
    Jacks, L.
    Yan, J.
    Cho, Y.
    Fyles, A.
    Milosevic, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S462 - S462
  • [36] Radiobiological modelling of dose-gradient effects in low dose rate, high dose rate and pulsed brachytherapy
    Armpilia, C.
    Dale, R. G.
    Sandilos, P.
    Vlachos, L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17): : 4399 - 4411
  • [37] A pulsed-dose study evaluating chronic toxicity of chlorothalonil to fish: A case study for environmental risk assessment
    Hamer, Mick
    Maynard, Samuel K.
    Schneider, Suzanne
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2019, 38 (07) : 1549 - 1559
  • [38] Dose volume histogram analysis of MRI-based intracavitary pulsed dose rate brachytherapy in cervical cancer
    Lindegaard, J.
    Tanderup, K.
    Gelineck, J.
    Nielsen, S. K.
    Christensen, J. J.
    Christensen, T. B.
    Nyvang, G-B.
    Jurik, A. G.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S78 - S78
  • [39] Dose rate in brachytherapy using after-loading machine: Pulsed or high-dose rate?
    Hannoun-Levi, J. -M.
    Peiffert, D.
    CANCER RADIOTHERAPIE, 2014, 18 (5-6): : 437 - 440
  • [40] Analysis of early complications and treatment tolerance in patients treated with pulsed-dose-rate brachytherapy
    Skowronek, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 : S56 - S56