A time-resolved fluoroimmunometric assay for the detection of microcystins, cyanobacterial peptide hepatotoxins

被引:23
|
作者
Mehto, P
Ankelo, M
Hinkkanen, A
Mikhailov, A
Eriksson, JE
Spoof, L
Meriluoto, J
机构
[1] Abo Akad Univ, Dept Biochem & Pharm, Turku 20521, Finland
[2] Turku Ctr Biotechnol, Turku 20521, Finland
[3] Univ Turku, Dept Biol, Turku 20014, Finland
关键词
blue-green algae; cyanobacteria; toxins; microcystins; time-resolved fluoroimmunoassay;
D O I
10.1016/S0041-0101(00)00215-4
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
An immunoassay based on the time-resolved fluorometry (TR-FIA) was developed for microcystins, cyanobacterial peptide hepatotoxins. The assay was performed in a competitive mode and it utilised the monoclonal antibodies raised against microcystin-LR, and a europium chelate of microcystin-LR as a competitive antigen. The sensitivity of the assay was 0.1 mug/l. The derection method of TR-FIA was compared to a commercially available kit based on the enzyme-linked immunosorbent assay (ELISA). The same level of sensitivity could be obtained with TR-FIA (in a non-optimised system). The simplified method of TR-FIA leads to a shorter analysis time. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:831 / 836
页数:6
相关论文
共 50 条
  • [21] Detection and analysis of the cyanobacterial peptide hepatotoxins microcystin and nodularin using SELDI-TOF mass spectrometry
    Yuan, M
    Carmichael, WW
    TOXICON, 2004, 44 (05) : 561 - 570
  • [22] Time-resolved singlet oxygen detection
    Nonell, S
    Braslavsky, SE
    SINGLET OXYGEN, UV-A, AND OZONE, 2000, 319 : 37 - 49
  • [23] Time-resolved detection of electrochemiluminescence of luminol
    Suomi, J
    Håkansson, M
    Jiang, QH
    Kotiranta, M
    Helin, M
    Niskanen, AJ
    Kulmala, S
    ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) : 167 - 169
  • [24] Time-resolved fluorescence detection on microfluidic chip for HIV-1 virus assay
    Sun, Yi
    Wang, Xiansong
    Xie, Fei
    Feng, Juan
    Ma, Xuemei
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1761 - 1765
  • [25] Time-resolved fluorometric assay for the detection of endostatin in chromatographically separated extracts of natural peptides
    John, H
    Schulz, S
    Forssmann, WG
    Ständker, L
    JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 268 (02) : 233 - 237
  • [26] Detection of hydrogen peroxide in river water via a microplate luminescence assay with time-resolved ("gated") detection
    Lei, W
    Dürkop, A
    Lin, ZH
    Wu, M
    Wolfbeis, OS
    MICROCHIMICA ACTA, 2003, 143 (04) : 269 - 274
  • [27] Detection of Hydrogen Peroxide in River Water via a Microplate Luminescence Assay with Time-Resolved (“Gated”) Detection
    Wu Lei
    Axel Dürkop
    Zhihong Lin
    Meng Wu
    Otto S. Wolfbeis
    Microchimica Acta, 2003, 143 : 269 - 274
  • [28] A TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY FOR THE MEASUREMENT OF PROLACTIN IN SERUM
    KAHAN, I
    PAPANASTASIOUDIAMANDI, A
    DCOSTA, M
    DIAMANDIS, E
    CLINICAL CHEMISTRY, 1988, 34 (06) : 1226 - 1226
  • [29] TIME-RESOLVED IMMUNOFLUOROMETRIC ASSAY FOR QUANTIFYING PROINSULIN IN SERUM
    ENGLING, US
    MISSLER, U
    KERNER, W
    CLINICAL CHEMISTRY, 1995, 41 (06) : 942 - 943
  • [30] COMPARISON OF TIME-RESOLVED FLUOROIMMUNOASSAY AND IMMUNOENZYMOMETRIC ASSAY FOR CLENBUTEROL
    BACIGALUPO, MA
    IUS, A
    MERONI, G
    DOVIS, M
    PETRUZZELLI, E