ROI RECONSTRUCTION FROM TRUNCATED CONE-BEAM PROJECTION

被引:4
|
作者
Azencott, Robert [1 ]
Bodmann, Bernhard G. [1 ]
Chowdhury, Tasadduk [1 ]
Labate, Demetrio [1 ]
Sen, Anando [2 ]
Vera, Daniel [3 ]
机构
[1] Univ Houston, Dept Math, Houston, TX 77204 USA
[2] Columbia Univ, Dept Biomed Informat, New York, NY 10032 USA
[3] Inst Tecnol Autonomo Mexico, Matemat, Mexico City 01080, CDMX, Mexico
基金
美国国家科学基金会;
关键词
Cone-beamtransform; interior tomography; region-of-interest tomography; ray transform; regularized reconstruction; IMAGE-RECONSTRUCTION; KATSEVICH ALGORITHM; IMPLEMENTATION; TRANSFORM; FRAMEWORK;
D O I
10.3934/ipi.2018002
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Region-of-Interest (ROI) tomography aims at reconstructing a region of interest C inside a body using only x-ray projections intersecting C and it is useful to reduce overall radiation exposure when only a small specific region of a body needs to be examined. We consider x-ray acquisition from sources located on a smooth curve G in Gamma mathbb R-3 verifying the classical Tuy condition. In this generic situation, the non-trucated cone-beam transform of smooth density functions f admits an explicit inverse Z as originally shown by Grangeat. However Z cannot directly reconstruct f from ROI-truncated projections. To deal with the ROI tomography problem, we introduce a novel reconstruction approach. For densities f in L-infinity(B) where B is a bounded ball in R-3, our method iterates an operator U combining ROI-truncated projections, inversion by the operator Z and appropriate regularization operators. Assuming only knowledge of projections corresponding to a spherical ROI C subset of subset B, given epsilon > 0, we prove that if C is sufficiently large our iterative reconstruction algorithm converges at exponential speed to an epsilon-accurate approximation of f in L-infinity. The accuracy depends on the regularity of f quantified by its Sobolev norm in W-5(B). Our result guarantees the existence of a critical ROI radius ensuring the convergence of our ROI reconstruction algorithm to an epsilon-accurate approximation of f. We have numerically verified these theoretical results using simulated acquisition of ROI-truncated cone-beam projection data for multiple acquisition geometries. Numerical experiments indicate that the critical ROI radius is fairly small with respect to the support region B.
引用
收藏
页码:29 / 57
页数:29
相关论文
共 50 条
  • [31] Fully truncated cone-beam reconstruction on pi lines using prior CT
    Ramamurthi, K
    Strobel, N
    Fahrig, R
    Prince, JL
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 1, 2005, 3749 : 631 - 638
  • [32] Cone-beam CT from width-truncated projections
    Cho, PS
    Rudd, AD
    Johnson, RH
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1996, 20 (01) : 49 - 57
  • [33] Rectification for cone-beam projection and backprojection
    Riddell, Cyril
    Trousset, Yves
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 950 - 962
  • [34] Reconstruction from Truncated Projections in Cone-beam CT using an Efficient 1D Filtering
    Xia, Yan
    Maier, Andreas
    Hofmann, Hannes G.
    Dennerlein, Frank
    Mueller, Kerstin
    Hornegger, Joachim
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [35] Reconstruction of a Cone-Beam CT Image Via Forward Iterative Projection Matching
    Brock, R.
    Docef, A.
    Murphy, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3112 - +
  • [36] Reconstruction of a cone-beam CT image via forward iterative projection matching
    Brock, R. Scott
    Docef, Alen
    Murphy, Martin J.
    MEDICAL PHYSICS, 2010, 37 (12) : 6212 - 6220
  • [37] Reconstruction from incomplete data in cone-beam tomography
    Hiriyannaiah, HP
    Satyaranjan, M
    Ramakrishnan, KR
    OPTICAL ENGINEERING, 1996, 35 (09) : 2748 - 2760
  • [38] Evaluation of the projection ordering for cone-beam CT
    Kong, Huihua
    Pan, Jinxiao
    Journal of Computational Information Systems, 2012, 8 (10): : 4031 - 4038
  • [39] Centers and centroids of the cone-beam projection of a ball
    Clackdoyle, R.
    Mennessier, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23): : 7371 - 7391
  • [40] A GENERAL CONE-BEAM RECONSTRUCTION ALGORITHM
    WANG, G
    LIN, TH
    CHENG, PC
    SHINOZAKI, DM
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (03) : 486 - 496