Evaluation of the Malvern Spraytec® with inhalation cell for the measurement of particle size distribution from metered dose inhalers

被引:34
|
作者
Haynes, A
Shaik, MS
Krarup, H
Singh, M [1 ]
机构
[1] Florida A&M Univ, Coll Pharm & Pharmaceut Sci, Div Pharmaceut, Tallahassee, FL 32307 USA
[2] Malvern Instruments Inc, Southborough, MA 01772 USA
关键词
laser diffraction; particle size analysis; metered dose inhaler; Spraytec (R); inhalation cell;
D O I
10.1002/jps.10558
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The purpose of this study was to evaluate the Malvern Spraytec(R) with inhalation cell attachment as a means of analyzing the particle size distribution of aerosols from pressurized metered dose inhalers (pMDIs). The aerosol particle size distribution of various commercially available, placebo, and experimental pMDI formulations was determined using Spraytec(R) under various experimental conditions and the relevant data were compared with the Andersen cascade impactor data. The Spraytec(R) volume median diameter (Dv 50) values for commercial chlorofluorocarbon- and hydrofluoroalkane (HFA)-based pMDIs were respectively smaller and higher compared with their reported mass median aerodynamic diameter values. It was possible to obtain a close agreement between Spraytec(R) D-v 50 and the reported mass median aerodynamic diameter values for a solution-type pMDI formulation, Qvar 50, by equilibrating the pMDI to 55 degreesC before the measurement and using a 20-cm throat extension. Incorporation of a nonvolatile solvent propylene glycol (PG) in placebo pMDIs (15% w/w ethanol, 0.5-20.0% w/w PG in HFA 134a) showed an increase in Dv 50 with increasing concentration of PG. Furthermore, it was possible to obtain a correlation (R-2 = 0.8037) between Spraytec(R) and Andersen cascade impactor data for the experimental nimesulide-pMDI formulations containing 0.1% w/w drug, 0.25-10% w/w PG, and 15% ethanol in HFA 134a. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:349 / 363
页数:15
相关论文
共 50 条
  • [11] EVALUATION OF INHALATION AIDS OF METERED DOSE INHALERS IN ASTHMATIC-CHILDREN
    LEE, H
    PEDIATRIC RESEARCH, 1985, 19 (04) : A408 - A408
  • [12] EVALUATION OF INHALATION AIDS OF METERED DOSE INHALERS IN ASTHMATIC-CHILDREN
    LEE, H
    EVANS, HE
    CHEST, 1987, 91 (03) : 366 - 369
  • [13] The influence of initial atomized droplet size on residual particle size from pressurized metered dose inhalers
    Sheth, Poonam
    Stein, Stephen W.
    Myrdal, Paul B.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2013, 455 (1-2) : 57 - 65
  • [14] DISPERSION AND SIZE DISTRIBUTION OF AMILORIDE BY METERED DOSE AND DRY POWDER INHALERS
    BOUNDY, MG
    LEITH, D
    KNOWLES, MR
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1990, 3 (04): : 233 - 241
  • [15] Metered-dose inhalers .1. Drug content and particle size distribution of beclomethasone dipropionate
    LeBelle, M
    Pike, RK
    Graham, SJ
    Ormsby, ED
    Bogard, HA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (07) : 793 - 800
  • [16] Evaluation of different parameters that affect droplet-size distribution from nasal sprays using the Malvern Spraytec®
    Dayal, P
    Shaik, MS
    Singh, M
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2004, 93 (07) : 1725 - 1742
  • [17] Influence of respiratory spacer devices on aerodynamic particle size distribution and fine particle mass of beclomethasone from metered-dose inhalers
    Feddah, MR
    Davies, NM
    Gipps, EM
    Brown, KF
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (04): : 477 - 485
  • [18] PARTICLE-SIZE DISTRIBUTION OF SINGLE AND MULTIPLE SPRAYS OF SALBUTAMOL METERED-DOSE INHALERS (MDIS)
    GRAHAM, SJ
    LAWRENCE, RC
    ORMSBY, ED
    PIKE, RK
    PHARMACEUTICAL RESEARCH, 1995, 12 (09) : 1380 - 1384
  • [19] Influence of single versus multiple actuations on the particle size distribution of beclometasone dipropionate metered-dose inhalers
    Feddah, MR
    Davies, NM
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2003, 55 (08) : 1055 - 1061
  • [20] Comparative evaluation of surfactant and hydrophobizing agent concentration in relation to the optimal particle size of metered-dose inhalers
    Fedina, LT
    Zelkó, R
    Fedina, LI
    Szabados, Z
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1998, 24 (09) : 853 - 856