Mid-term Outcomes of Using Custom-Made Implants for Revision Hip Arthroplasty

被引:4
|
作者
Kovalenko, A. N. [1 ]
Dzhavadov, A. A. [1 ]
Shubnykov, I. I. [1 ]
Bilyk, S. S. [1 ]
Denisov, A. O. [1 ]
Cherkasov, M. A. [1 ]
Midaev, A. I. [1 ]
Tikhilov, R. M. [1 ,2 ,3 ]
机构
[1] Vreden Russian Res Inst Traumatol & Orthoped, St Petersburg, Russia
[2] Vreden Russian Res Inst Traumatol & Orthoped, Sci Med, St Petersburg, Russia
[3] Mechnikov North Western State Med Univ, Traumatol & Orthoped Dept, St Petersburg, Russia
来源
TRAVMATOLOGIYA I ORTOPEDIYA ROSSII | 2019年 / 25卷 / 03期
关键词
custom-made implants; hip revision arthroplasty; ACETABULAR COMPONENTS; EPIDEMIOLOGY; CLASSIFICATIONS; SATISFACTION; RELIABILITY; ACCURACY; VALIDITY; DEFECTS; KNEE;
D O I
10.21823/2311-2905-2019-25-3-37-46
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction. The matter of the replacement of acetabular defects is becoming increasingly relevant today. In their clinic the authors used custom-made implants with trabecular coating for replacement of defects in the acetabulum where and when it was necessary to ensure extended fixation of the component. Purpose - to evaluate short-teen clinical and functional outcomes, osteointegration of porous coated custom-made implants, the overall survival of structural components and to identify the causes of failures and complications. Materials and Methods. During the study the authors interviewed and evaluated radiographs of 48 patients operated from October 2015 to June 2018. The patients were interviewed before and after the surgery using the Oxford hip joint scale, quality of life EQ-5D and visual analogue pain scale. Radiographs were evaluated for a period of at least 12 months for the signs of osteointegration. Results. The average OHS scores increased from 14.9 (+/- 7) to 37.6 (+/- 7) (p<0.01). Quality of life according to the EQ-5D index increased from 0.2 (+/- 0.2) to 0.7 (+/- 0.2) (p<0.01). The average value by general health scales: before operations - 49 (+/- 17) and 73 (+/- 18) scores after surgeries (p<0.01). The average VAS pain score decreased from 73 (+/- 10) to 19 (+/- 19) points (p<0.01). Osteointegration was observed in 98 percent of cases. Migration of the implant with fracture of a flange was observed in one case. Conclusions. In the short-term follow up the use of custom-made implants significantly improves hip joint function and the patients' life quality. Custom-made implants enable primary reliable fixation in case of complex acetabular defects. High rate of osteointegration is observed for custom-made implants with porous coating within at least 12 months. Longer follow-up is needed to evaluate long-term results.
引用
收藏
页码:37 / 46
页数:10
相关论文
共 50 条
  • [1] Custom-made acetabular implants in revision total hip arthroplasty
    von Lewinski, Gabriela
    [J]. ORTHOPADE, 2020, 49 (05): : 417 - 423
  • [2] Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss
    Froeschen, F. S.
    Randau, T. M.
    Hischebeth, G. T. R.
    Gravius, N.
    Gravius, S.
    Walter, S. G.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (02) : 263 - 273
  • [3] Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss
    F. S. Fröschen
    T. M. Randau
    G. T. R. Hischebeth
    N. Gravius
    S. Gravius
    S. G. Walter
    [J]. Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 263 - 273
  • [4] The Clinical Outcome of Custom-Made Implants in Primary and Revision Hip Arthroplasty
    Winter, P.
    Kurz, K.
    Jung, A.
    Roch, J.
    Wolf, M.
    Siebel, T.
    [J]. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2022, 89 (06) : 423 - 428
  • [5] Early outcomes of using custom-made augments in revision total hip arthroplasty
    R. M. Tikhilov
    A. A. Dzhavadov
    A. S. Demin
    S. S. Bilyk
    A. O. Denisov
    I. I. Shubnyakov
    [J]. International Orthopaedics, 2022, 46 : 2229 - 2235
  • [6] Early outcomes of using custom-made augments in revision total hip arthroplasty
    Tikhilov, R. M.
    Dzhavadov, A. A.
    Demin, A. S.
    Bilyk, S. S.
    Denisov, A. O.
    Shubnyakov, I. I.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2022, 46 (10) : 2229 - 2235
  • [7] Standard Versus Custom-Made Acetabular Implants in Revision Total Hip Arthroplasty
    Tikhilov, Rashid M.
    Dzhavadov, Alisagib A.
    Kovalenko, Anton N.
    Bilyk, Stanislav S.
    Denisov, Alexey O.
    Shubnyakov, Igor I.
    [J]. JOURNAL OF ARTHROPLASTY, 2022, 37 (01): : 119 - 125
  • [8] Mid-Term Outcomes of Revision Hip Arthroplasty with Acetabular Augments
    Korytkin, A. A.
    Novikova, Ya S.
    Kovaldov, K. A.
    Korolev, S. B.
    Zykin, A. A.
    Gerasimov, S. A.
    Gerasimov, E. A.
    [J]. TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2019, 25 (01): : 9 - 18
  • [9] Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis
    Medenica, Ivica
    Lukovic, Milan
    Radoicic, Dragan
    [J]. VOJNOSANITETSKI PREGLED, 2010, 67 (02) : 179 - 182
  • [10] Comparative Evaluation of Custom-Made Components and Standard Implants for Acetabular Reconstruction in Revision Total Hip Arthroplasty
    Murylev, Valery Yu.
    Kukovenko, Grigory A.
    Elizarov, Pavel M.
    Rukin, Yaroslav A.
    Muzychenkov, Aleksey V.
    Rudnev, Alexander I.
    Zhuchkov, Aleksandr G.
    Alekseev, Semen S.
    Bobrov, Dmitry S.
    Germanov, Valery G.
    [J]. TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2023, 29 (03): : 18 - 30