Comparative Evaluation of Custom-Made Components and Standard Implants for Acetabular Reconstruction in Revision Total Hip Arthroplasty

被引:1
|
作者
Murylev, Valery Yu. [1 ,2 ]
Kukovenko, Grigory A. [1 ,2 ]
Elizarov, Pavel M. [1 ,2 ]
Rukin, Yaroslav A. [2 ]
Muzychenkov, Aleksey V. [1 ,2 ]
Rudnev, Alexander I. [1 ,2 ]
Zhuchkov, Aleksandr G. [1 ]
Alekseev, Semen S. [1 ]
Bobrov, Dmitry S. [1 ,2 ]
Germanov, Valery G. [2 ]
机构
[1] SP Botkin Moscow City Clin Hosp, 8 2,Trubetskaya Str, Moscow 119991, Russia
[2] IM Sechenov First Moscow State Med Univ, Sechenov Univ, 8 2,Trubetskaya Str, Moscow 119991, Russia
来源
TRAVMATOLOGIYA I ORTOPEDIYA ROSSII | 2023年 / 29卷 / 03期
关键词
revision total hip arthroplasty; acetabular defects; disruption of pelvic ring integrity; custom-made acetabular components; 3D printing; DEFECTS; CLASSIFICATIONS; EPIDEMIOLOGY; THA;
D O I
10.17816/2311-2905-2553
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. The use of custom-made acetabular components is one of the promising methods for reconstruction of the acetabulum in cases of significant defects, including those associated with pelvic bone dissociation. It allows achieving stable fixation and restoring the biomechanics of the hip joint. Aim of the study - to compare the results of using individually designed components, supportive antiprotrusion rings, augments, and hemispherical components in revision total hip arthroplasty for type IIIB bone defects according to Paprosky classification. Methods. The study analyzed the treatment outcomes of 90 patients with type IIIB bone defects who underwent revision total hip arthroplasty between 2017 and 2022. Patients were divided into three groups: the first group received individually designed acetabular components, the second group received augments with hemispheres, and the third group had antiprotrusion cages implanted. The analysis included the reasons for revision surgery, operation duration, blood loss volume, and type of revision procedure. Pain and functional outcomes were assessed with WOMAC, Harris Hip Score, and VAS scales. Results. 3D-printed constructs were more frequently implanted in patients with pelvic bone dissociation. The first group showed a significantly positive dynamic in functional outcomes. Complications were diagnosed in 27 ( 30%) cases: joint instability (dislocation) in 10 (11.1%) patients, periprosthetic infection in 8 (8.8%), aseptic loosening in 4 (4.4%), and sciatic nerve neuropathy in 5 (5.5%) patients. The number of these complications was higher in the second and third groups of patients. Conclusion. Custom-made implants using 3D technologies are a preferable option for revision total hip arthroplasty in patients with type IIIB defects according to Paprosky classification, especially in cases of pelvic bone dissociation.
引用
收藏
页码:18 / 30
页数:13
相关论文
共 50 条
  • [1] Standard Versus Custom-Made Acetabular Implants in Revision Total Hip Arthroplasty
    Tikhilov, Rashid M.
    Dzhavadov, Alisagib A.
    Kovalenko, Anton N.
    Bilyk, Stanislav S.
    Denisov, Alexey O.
    Shubnyakov, Igor I.
    JOURNAL OF ARTHROPLASTY, 2022, 37 (01): : 119 - 125
  • [2] Custom-made acetabular implants in revision total hip arthroplasty
    von Lewinski, Gabriela
    ORTHOPADE, 2020, 49 (05): : 417 - 423
  • [3] Acetabular custom-made implants for severe acetabular bone defect in revision total hip arthroplasty: a systematic review of the literature
    Chiarlone, Francesco
    Zanirato, Andrea
    Cavagnaro, Luca
    Alessio-Mazzola, Mattia
    Felli, Lamberto
    Burastero, Giorgio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (03) : 415 - 424
  • [4] Acetabular custom-made implants for severe acetabular bone defect in revision total hip arthroplasty: a systematic review of the literature
    Francesco Chiarlone
    Andrea Zanirato
    Luca Cavagnaro
    Mattia Alessio-Mazzola
    Lamberto Felli
    Giorgio Burastero
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 415 - 424
  • [5] A modified custom-made triflanged acetabular reconstruction ring (MCTARR) for revision hip arthroplasty with severe acetabular defects
    Colen, Sascha
    Harake, Ramzi
    De Haan, Julien
    Muleir, Michiel
    ACTA ORTHOPAEDICA BELGICA, 2013, 79 (01): : 71 - 75
  • [6] The Clinical Outcome of Custom-Made Implants in Primary and Revision Hip Arthroplasty
    Winter, P.
    Kurz, K.
    Jung, A.
    Roch, J.
    Wolf, M.
    Siebel, T.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2022, 89 (06) : 423 - 428
  • [7] Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis
    Medenica, Ivica
    Lukovic, Milan
    Radoicic, Dragan
    VOJNOSANITETSKI PREGLED, 2010, 67 (02) : 179 - 182
  • [8] Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss
    F. S. Fröschen
    T. M. Randau
    G. T. R. Hischebeth
    N. Gravius
    S. Gravius
    S. G. Walter
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 263 - 273
  • [9] Mid-term results after revision total hip arthroplasty with custom-made acetabular implants in patients with Paprosky III acetabular bone loss
    Froeschen, F. S.
    Randau, T. M.
    Hischebeth, G. T. R.
    Gravius, N.
    Gravius, S.
    Walter, S. G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (02) : 263 - 273
  • [10] Use of custom triflanged acetabular components in revision total hip arthroplasty
    Holt, GE
    Dennis, DA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) : 209 - 214