Current Sensors Fault Detection and Tolerant Control for Induction Motor Drive

被引:4
|
作者
Adamczyk, Michal [1 ]
Orlowska-Kowalska, Teresa [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Dept Elect Machines Drives & Measurements, Wroclaw, Poland
关键词
induction motor; direct rotor flux oriented control; current sensor faults; fault detection; virtual current sensor; fault tolerant control; DIRECT TORQUE CONTROL; DIAGNOSIS;
D O I
10.1109/PEMC48073.2021.9432575
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper current sensor fault tolerant control fault direct rotor flux oriented induction motor drive has been presented. The simulation tests have been carried out when A-phase or/and B-phase sensors have failed. The solution proposes the use of the Virtual Current Sensor (VCS) algorithm based on the direct current (DC) voltage and the rotor angular Velocity, which is reconstructing the values of the stator phase currents in a stationary reference frame (alpha, beta). A simple algorithm for detecting and locating current sensor fault has been proposed. Simulation studies under different operating conditions of the drive showed high efficiency of the presented method.
引用
收藏
页码:888 / 892
页数:5
相关论文
共 50 条
  • [21] Adaptive Fault Tolerant Direct Torque Control Structure of the Induction Motor Drive
    Klimkowski, Kamil
    Dybkowski, Mateusz
    [J]. 2015 INTERNATIONAL CONFERENCE ON ELECTRICAL DRIVES AND POWER ELECTRONICS (EDPE), 2015, : 7 - 12
  • [22] Speed Sensor Fault Tolerant Direct Torque Control of Induction Motor Drive
    Dybkowski, Mateusz
    Klimkowski, Kamil
    Orlowska-Kowalska, Teresa
    [J]. 2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 679 - 684
  • [23] Fault-Tolerant Converter Topology for Speed Control of Induction Motor Drive
    Yelamarthi, Bhaskar S. S. Gupta
    Sandepudi, Srinivasa Rao
    [J]. 2020 INTERNATIONAL CONFERENCE ON EMERGING FRONTIERS IN ELECTRICAL AND ELECTRONIC TECHNOLOGIES (ICEFEET 2020), 2020,
  • [24] Virtual Current Sensor in the Fault-Tolerant Field-Oriented Control Structure of an Induction Motor Drive
    Adamczyk, Michal
    Orlowska-Kowalska, Teresa
    [J]. SENSORS, 2019, 19 (22)
  • [25] Fault-tolerant control for current sensors of doubly fed induction generators based on an improved fault detection method
    Li, H.
    Yang, C.
    Hu, Y. G.
    Zhao, B.
    Zhao, M.
    Chen, Z.
    [J]. MEASUREMENT, 2014, 47 : 929 - 937
  • [26] Fault Tolerant Control Design of Induction Motor Drive in Electrical Vehicle: A Hybrid Control Approach
    Boukhnifer, M.
    Raisemche, A.
    Diallo, D.
    [J]. 2013 21ST MEDITERRANEAN CONFERENCE ON CONTROL AND AUTOMATION (MED), 2013, : 40 - 45
  • [27] Backstepping Fault Tolerant Control for Induction Motor
    Roubache, T.
    Chaouch, S.
    Said, M. S. Nait
    [J]. 2014 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2014, : 472 - 477
  • [28] Sensor fault tolerant control for induction motor
    Ben Zina, Habib
    Allouche, Moez
    Chaabane, Mohamed
    Souissi, Mansour
    [J]. 2015 16TH INTERNATIONAL CONFERENCE ON SCIENCES AND TECHNIQUES OF AUTOMATIC CONTROL AND COMPUTER ENGINEERING (STA), 2015, : 251 - 255
  • [29] Fuzzy fault tolerant control of an induction motor
    Benaicha, Samira
    Nait-Said, Rachid
    Zidani, Fatiha
    Nait-Said, Mohamed-Said
    [J]. INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2008, 4 (02) : 160 - 167
  • [30] A Robust Current Sensor Fault Detection Scheme for Sensorless Induction Motor Drive
    Manohar, Murli
    Das, Sukanta
    Kumar, Rahul
    [J]. 2017 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2017,