DNA cycle sequencing of a common restriction fragment of Staphylococcus aureus bacteriophages by capillary electrophoresis using replaceable linear polyacrylamide

被引:5
|
作者
Klepárník, K
Berka, J
Foret, F
Doskar, J
Kailerová, J
Rosypal, S
Bocek, P
机构
[1] Acad Sci Czech Republ, Inst Analyt Chem, CZ-61142 Brno, Czech Republic
[2] Masaryk Univ, Fac Sci, Dept Genet & Mol Biol, CS-61137 Brno, Czech Republic
基金
中国国家自然科学基金;
关键词
capillary electrophoresis; Staphylococcus aureus bacteriophage; DNA cycle sequencing; linear polyacrylamide;
D O I
10.1002/elps.1150190516
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The nucleotide sequence of a part of a 4.9 kbp common restriction fragment isolated from Staphylococcus aureus bacteriophage (bacterial virus) 3A has been determined by capillary electrophoresis (CE). The fast separation of sequencing fragments in linear polyacrylamide solution at a temperature of 55 degrees C allowed the reading of more than 650 bases of sequence in 60 min. The single strand (ss)DNA fragments were prepared by cycle sequencing with fluorescently labeled dideoxy-terminators on the cloned bacteriophage DNA template. With respect to analysis speed, sequence read-length, low sample consumption and automation, CE offers a simple, labor-saving and inexpensive procedure for DNA sequencing. Operating the CE columns at elevated temperature proved to be a rapid procedure capable of extending sequence read-length. The resulting sequence of the common restriction fragment can be used for the preparation of specific primers and oligonucleotide hybridization probes for identification of Staphylococcus aureus bacteriophages and/or prophages belonging to the bacteriophage species 3A.
引用
收藏
页码:695 / 700
页数:6
相关论文
共 20 条
  • [1] SEPARATION OF DNA FRAGMENTS BY CAPILLARY ELECTROPHORESIS USING REPLACEABLE LINEAR POLYACRYLAMIDE MATRICES
    PARIAT, YF
    BERKA, J
    HEIGER, DN
    SCHMITT, T
    VILENCHIK, M
    COHEN, AS
    FORET, F
    KARGER, BL
    JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) : 57 - 66
  • [2] DNA-SEQUENCING BY CAPILLARY ELECTROPHORESIS WITH REPLACEABLE LINEAR POLYACRYLAMIDE AND LASER-INDUCED FLUORESCENCE DETECTION
    RUIZMARTINEZ, MC
    BERKA, J
    BELENKII, A
    FORET, F
    MILLER, AW
    KARGER, BL
    ANALYTICAL CHEMISTRY, 1993, 65 (20) : 2851 - 2858
  • [3] Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions
    Carrilho, E
    RuizMartinez, MC
    Berka, J
    Smirnov, I
    Goetzinger, W
    Miller, AW
    Brady, D
    Karger, BL
    ANALYTICAL CHEMISTRY, 1996, 68 (19) : 3305 - 3313
  • [4] DNA sequencing up to 1300 bases in two hours by capillary electrophoresis with mixed replaceable linear polyacrylamide solutions
    Zhou, HH
    Miller, AW
    Sosic, Z
    Buchholz, B
    Barron, AE
    Kotler, L
    Karger, BL
    ANALYTICAL CHEMISTRY, 2000, 72 (05) : 1045 - 1052
  • [5] Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions
    Salas-Solano, O
    Carrilho, E
    Kotler, L
    Miller, AW
    Goetzinger, W
    Sosic, Z
    Karger, BL
    ANALYTICAL CHEMISTRY, 1998, 70 (19) : 3996 - 4003
  • [6] DNA sequencing of close to 1000 bases in 40 minutes by capillary electrophoresis using dimethyl sulfoxide and urea as denaturants in replaceable linear polyacrylamide solutions
    Kotler, L
    He, H
    Miller, AW
    Karger, BL
    ELECTROPHORESIS, 2002, 23 (17) : 3062 - 3070
  • [7] Characterization of high molecular mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis
    Goetzinger, W
    Kotler, L
    Carrilho, E
    Ruiz-Martinez, MC
    Salas-Solano, O
    Karger, BL
    ELECTROPHORESIS, 1998, 19 (02) : 242 - 248
  • [8] DNA fragment analysis using fast cycle capillary electrophoresis
    Dailey, D
    Johnson, MD
    Tynan, K
    Wenz, MH
    AMERICAN JOURNAL OF PATHOLOGY, 1998, 153 (05): : 1664 - 1664
  • [9] DNA sequencing by capillary electrophoresis using mixtures of polyacrylamide and poly(N,N-dimethylacrylamide)
    Song, LG
    Liang, D
    Chen, Z
    Fang, D
    Chu, B
    JOURNAL OF CHROMATOGRAPHY A, 2001, 915 (1-2) : 231 - 239
  • [10] EFFECTS OF LINEAR POLYACRYLAMIDE CONCENTRATIONS AND APPLIED VOLTAGES ON THE SEPARATION OF OLIGONUCLEOTIDES AND DNA-SEQUENCING FRAGMENTS BY CAPILLARY ELECTROPHORESIS
    MANABE, T
    CHEN, N
    TERABE, S
    YOHDA, M
    ENDO, I
    ANALYTICAL CHEMISTRY, 1994, 66 (23) : 4243 - 4252