Rapid DNA sequencing of more than 1000 bases per run by capillary electrophoresis using replaceable linear polyacrylamide solutions

被引:174
|
作者
Carrilho, E
RuizMartinez, MC
Berka, J
Smirnov, I
Goetzinger, W
Miller, AW
Brady, D
Karger, BL
机构
[1] NORTHEASTERN UNIV,BARNETT INST,BOSTON,MA 02115
[2] NORTHEASTERN UNIV,DEPT CHEM,BOSTON,MA 02115
关键词
D O I
10.1021/ac960411r
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The read length for DNA sequencing using capillary electrophoresis and replaceable linear polyacrylamide (LPA) solutions has been extended to more than 1000 bases with a run time of 80 min. This result was successfully achieved through the combined use of cycle sequencing with dye-labeled primers, improved matrix and separation conditions, and enhanced base-calling software. The influences of LPA molecular weight and concentration on separation were investigated. Additionally, the separation buffer, column temperature, and electric field were adjusted to increase the number of resolvable DNA fragments per run while maintaining an enhanced separation speed. Using low concentrations [2% (w/v)] of high molecular weight LPA polymers (>5.5 x 10(6) Da), elevated column temperature (50 degrees C) and moderately high field (150 V/cm), rapid sequencing analysis for more than 1000 bases on a model ssM13mp18 template was obtained with 96.8% accuracy.
引用
收藏
页码:3305 / 3313
页数:9
相关论文
共 24 条
  • [1] Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions
    Salas-Solano, O
    Carrilho, E
    Kotler, L
    Miller, AW
    Goetzinger, W
    Sosic, Z
    Karger, BL
    ANALYTICAL CHEMISTRY, 1998, 70 (19) : 3996 - 4003
  • [2] DNA sequencing of close to 1000 bases in 40 minutes by capillary electrophoresis using dimethyl sulfoxide and urea as denaturants in replaceable linear polyacrylamide solutions
    Kotler, L
    He, H
    Miller, AW
    Karger, BL
    ELECTROPHORESIS, 2002, 23 (17) : 3062 - 3070
  • [3] DNA sequencing up to 1300 bases in two hours by capillary electrophoresis with mixed replaceable linear polyacrylamide solutions
    Zhou, HH
    Miller, AW
    Sosic, Z
    Buchholz, B
    Barron, AE
    Kotler, L
    Karger, BL
    ANALYTICAL CHEMISTRY, 2000, 72 (05) : 1045 - 1052
  • [4] SEPARATION OF DNA FRAGMENTS BY CAPILLARY ELECTROPHORESIS USING REPLACEABLE LINEAR POLYACRYLAMIDE MATRICES
    PARIAT, YF
    BERKA, J
    HEIGER, DN
    SCHMITT, T
    VILENCHIK, M
    COHEN, AS
    FORET, F
    KARGER, BL
    JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (01) : 57 - 66
  • [5] DNA-SEQUENCING BY CAPILLARY ELECTROPHORESIS WITH REPLACEABLE LINEAR POLYACRYLAMIDE AND LASER-INDUCED FLUORESCENCE DETECTION
    RUIZMARTINEZ, MC
    BERKA, J
    BELENKII, A
    FORET, F
    MILLER, AW
    KARGER, BL
    ANALYTICAL CHEMISTRY, 1993, 65 (20) : 2851 - 2858
  • [6] DNA cycle sequencing of a common restriction fragment of Staphylococcus aureus bacteriophages by capillary electrophoresis using replaceable linear polyacrylamide
    Klepárník, K
    Berka, J
    Foret, F
    Doskar, J
    Kailerová, J
    Rosypal, S
    Bocek, P
    ELECTROPHORESIS, 1998, 19 (05) : 695 - 700
  • [7] Characterization of high molecular mass linear polyacrylamide powder prepared by emulsion polymerization as a replaceable polymer matrix for DNA sequencing by capillary electrophoresis
    Goetzinger, W
    Kotler, L
    Carrilho, E
    Ruiz-Martinez, MC
    Salas-Solano, O
    Karger, BL
    ELECTROPHORESIS, 1998, 19 (02) : 242 - 248
  • [8] Polyacrylamide solutions for DNA sequencing by capillary electrophoresis: Mesh sizes, separation and dispersion
    Wu, CH
    Quesada, MA
    Schneider, DK
    Farinato, R
    Studier, FW
    Chu, B
    ELECTROPHORESIS, 1996, 17 (06) : 1103 - 1109
  • [10] Separation of DNA sequencing fragments up to 1000 bases by using poly(ethylene oxide)-filled capillary electrophoresis
    Kim, Y
    Yeung, ES
    JOURNAL OF CHROMATOGRAPHY A, 1997, 781 (1-2) : 315 - 325