Finite time exergoeconomic performance of an irreversible intercooled regenerative Brayton cogeneration plant

被引:18
|
作者
Yang, B. [1 ]
Chen, L. G. [1 ]
Sun, F. R. [1 ]
机构
[1] Naval Univ Engn, Postgrad Sch, Wuhan 430033, Peoples R China
基金
中国国家自然科学基金;
关键词
Finite time thermodynamics; Irreversible intercooled regenerative Brayton cogeneration plant; Exergoeconomic performance; Profit rate; Exergetic efficiency; ENTROPY GENERATION MINIMIZATION; MAXIMUM-PROFIT PERFORMANCE; HEAT-TRANSFER LAW; OPTIMIZATION; CYCLE; THERMODYNAMICS; CRITERION;
D O I
10.1179/014426010X12845670050761
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A thermodynamic model of an irreversible intercooled regenerative Brayton heat and power cogeneration plant coupled to constant temperature heat reservoirs is established in this paper using finite time thermodynamics. The intercooler and the irreversible compression and expansion losses in the low and high pressure compressors and the turbine are taken into account. The finite time exergoeconomic performance of the cogeneration plant is investigated. The analytical formulae about dimensionless profit rate and exergetic efficiency are derived. The numerical examples show that there exist two different optimal values of intercooling pressure ratio, which correspond to an optimal value of dimensionless profit rate and an optimal value of exergetic efficiency respectively for the fixed total pressure ratio. There also exist optimal total pressure ratios corresponding to maximum profit rate and maximum exergetic efficiency respectively for the variable total pressure ratio. It is also found that there exist optimal consumer side temperatures, which lead to a double maximum profit rate and a double maximum exergetic efficiency respectively.
引用
收藏
页码:5 / 12
页数:8
相关论文
共 50 条
  • [21] Effects of intercooling on the performance of an irreversible regenerative Brayton cycle
    Tyagi, S. K.
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2009, 28 (04) : 231 - 245
  • [22] Optimum criteria based on different pressure ratios of an irreversible intercooled-regenerative-reheat Brayton cycle
    Tyagi, S. K.
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2010, 29 (04) : 191 - 210
  • [23] Exergetic performance optimisation of an endoreversible intercooled regenerated Brayton cogeneration plant. Part 1: thermodynamic model and parametric analysis
    Chen, Lingen
    Yang, Bo
    Sun, Fengrui
    Wu, Chih
    [J]. INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2011, 32 (03) : 116 - 123
  • [24] MODELLING, ANALYSES AND OPTIMIZATION FOR EXERGY PERFORMANCE OF AN IRREVERSIBLE INTERCOOLED REGENERATED BRAYTON CHP PLANT. PART 2. PERFORMANCE OPTIMIZATION
    Yang, Bo
    Chen, Lingen
    Feng, Huijun
    Ding, Zemin
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017 VOL 6, 2018,
  • [25] Optimal Finite Time Exergoeconomic Performance of an Irreversible Quantum Harmonic Carnot Refrigerator
    Liu, Xiao-Wei
    Chen, Lin-Gen
    Ding, Ze-Min
    Wu, Feng
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2019, 40 (05): : 974 - 981
  • [26] Effects of intercooling on the performance of an irreversible regenerative modified Brayton cycle
    Department of Building Services Engineering, Hong Kong Polytechnic University, Hung Horn, Kowloon, Hong Kong
    不详
    不详
    不详
    [J]. Int J Power Energy Syst, 2007, 3 (256-264): : 256 - 264
  • [27] Exergoeconomic performance analysis and optimisation of an irreversible-closed intercooled regenerated gas turbine cycle
    Ge, Yanlin
    Wang, Wenhua
    Chen, Lingen
    Meng, Fankai
    [J]. INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 42 (02) : 211 - 219
  • [28] Performance analysis for an irreversible variable temperature heat reservoir closed intercooled regenerated Brayton cycle
    Wang, WH
    Chen, LG
    Sun, FR
    Wu, C
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (17) : 2713 - 2732
  • [29] Exergetic performance optimization of an endoreversible intercooled regenerated Brayton cogeneration plant. Part 2: Exergy output rate and exergy efficiency optimization
    Yang, Bo
    Chen, Lingen
    Sun, Fengrui
    Wu, Chih
    [J]. INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2012, 33 (02) : 98 - 104
  • [30] Optimal criteria for different parameters of an irreversible regenerative intercooled Brayton cycle under maximum power and maximum ecological COP conditions
    Tyagi, S. K.
    Wang, S. W.
    Chen, G. M.
    Han, X. H.
    Kaushik, S. C.
    [J]. INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2006, 27 (01) : 37 - 51