Suture button versus syndesmosis screw fixation in pronation-external rotation ankle fractures: A minimum 6-year follow-up of a randomised controlled trial

被引:35
|
作者
Lehtola, Ristomatti [1 ,6 ]
Leskela, Hannu-Ville [1 ]
Flinkkila, Tapio [1 ]
Pakarinen, Harri [1 ,2 ]
Niinimaki, Jaakko [3 ]
Savola, Olli [4 ]
Ohtonen, Pasi [5 ]
Kortekangas, Tero [1 ]
机构
[1] Oulu Univ Hosp, Dept Surg, Div Orthopaed & Trauma Surg, Kajaanintie 50,POB 21, FI-90029 Oulu, Finland
[2] Pohjola Hosp, Kiilakivenkuja 1, Oulu 90250, Finland
[3] Oulu Univ Hosp, Dept Radiol, Kajaanintie 50,POB 21, FI-90029 Oulu, Finland
[4] Pohjola Hosp, Puutarhurinkuja 2, Helsinki 00300, Finland
[5] Oulu Univ Hosp, Div Operat Care, Kajaanintie 50,POB 21, FI-90029 Oulu, Finland
[6] Univ Oulu, Med Res Ctr Oulu, Pentti Kaiteran Katu 1,POB 8000, FI-90014 Oulu, Finland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2021年 / 52卷 / 10期
关键词
Ankle fracture; Syndesmosis; Syndesmosis screw; Suture button; Malreduction; DISTAL TIBIOFIBULAR JOINT; MALREDUCTION; INJURIES; OUTCOMES; OSTEOARTHRITIS; REDUCTION; TIGHTROPE; COMPLICATIONS; ACCURACY;
D O I
10.1016/j.injury.2021.06.025
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Randomised controlled trials (RCT) with short-term follow-ups have shown that, in treatment of syndesmosis injuries, a suture button device (SB) resulted in better radiographic and functional outcome compared to syndesmosis screw fixation (SS). However, only one RCT has reported long-term results; thus, the syndesmosis malreduction rates for both implants might increase during longer follow-up. The primary objective of this RCT was to evaluate the maintenance of syndesmosis reduction with the SS compared to the SB fixation in patients during a minimum follow-up of 6-years. The secondary objectives were to assess the post-traumatic osteoarthritis (OA) grade and the functional outcome. Patients and Methods: At Oulu University Hospital, between January 2010 and December 2011, we enrolled 43 patients with Lauge-Hansen pronation-external rotation type 4/Weber C, ankle fractures with unstable syndesmosis. Patients were randomised to treatment with either a single 3.5-mm tricortical SS (22 patients) or an SB (21 patients). The mean follow-up was 7.1 years (range, 6.2-7.9). Syndesmosis reduction and OA grade was assessed with standing cone-beam computed tomography (CBCT) of both ankles. Malreduction was defined as >2 mm side-to-side difference in the mean width of the syndesmosis. OA was graded according to the Morrey & Wiedeman classification. The Olerud-Molander Ankle Outcome Score (OMAS) and a quality of life questionnaire (RAND 36-Item Health Survey) were used to evaluate functional outcome. Results: Two syndesmoses in the SS group and one in the SB group were malreduced (P = 0.58). Moderate OA after a mean of 7 years post-injury was common. In the SS and SB groups, 9 of 16 and 11 of 13 patients, respectively, had one or more grades serious OA in the injured ankle than in the uninjured ankle (P = 0.11). The mean OMAS was 88 in the SS group and 78 in the SB group (difference between means 7.1, 95% CI: - 7.0-21.1, P = 0.32). The RAND-36 results did not differ between groups. Conclusion: The SS and SB maintained syndesmosis reduction equally well during follow-up. Our study findings also suggest that both methods result in moderate OA rates and the functional outcome is comparable between these two syndesmosis fixation methods. (C) 2021 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:3143 / 3149
页数:7
相关论文
共 50 条
  • [21] A novel percutaneous achievement and maintenance of reduction and screw fixation for acute displaced scaphoid fractures: minimum two-year follow-up
    Yadong Yu
    Haibin Cui
    Xiaoliang Yang
    Xiaofei Yu
    Yanbin Bai
    International Orthopaedics, 2018, 42 : 1911 - 1916
  • [22] External Fixation and Adjuvant Pins Versus Volar Locking Plate Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study With a 5-Year Follow-Up
    Williksen, John H.
    Husby, Torstein
    Hellund, Johan C.
    Kvernmo, Hebe D.
    Rosales, Carina
    Frihagen, Frede
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (07): : 1333 - 1340
  • [23] Displaced intra-articular calcaneal fractures: 15-Year follow-up of a randomised controlled trial of conservative versus operative treatment
    Ibrahim, T.
    Rowsell, M.
    Rennie, W.
    Brown, A. R.
    Taylor, G. J. S.
    Gregg, P. J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (07): : 848 - 855
  • [24] Effects of New Complementary Feeding Guidelines on Eating Behaviour, Food Consumption and Growth in Colombian Children: 6-Year Follow-Up of a Randomised Controlled Trial
    Vega, Gilma Olaya
    Fewtrell, Mary
    NUTRIENTS, 2024, 16 (14)
  • [25] TMC trial: 3 year follow-up on randomised controlled trial of tacrolimus versus microemulsified cyclosporine in liver transplantation.
    O'Grady, JG
    HEPATOLOGY, 2004, 40 (04) : 551A - 551A
  • [26] Unipolar hemiarthroplasty versus bipolar hemiarthroplasty in patients with displaced femoral neck fractures. A four-year follow-up of a randomised controlled trial
    Christian Inngul
    Carl-Johan Hedbeck
    Richard Blomfeldt
    Gunilla Lapidus
    Sari Ponzer
    Anders Enocson
    International Orthopaedics, 2013, 37 : 2457 - 2464
  • [27] Unipolar hemiarthroplasty versus bipolar hemiarthroplasty in patients with displaced femoral neck fractures. A four-year follow-up of a randomised controlled trial
    Inngul, Christian
    Hedbeck, Carl-Johan
    Blomfeldt, Richard
    Lapidus, Gunilla
    Ponzer, Sari
    Enocson, Anders
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (12) : 2457 - 2464
  • [28] Single-Bundle versus Double-Bundle Anterior Cruciate Ligament Reconstruction: A Prospective Randomized Controlled Trial with 6-Year Follow-up
    Adravanti, Paolo
    Dini, Francesco
    de Girolamo, Laura
    Cattani, Massimo
    Rosa, Michele Attilio
    JOURNAL OF KNEE SURGERY, 2017, 30 (09) : 898 - 904
  • [29] Laparoscopic mesh sacrohysteropexy versus vaginal hysterectomy: 7-year follow-up from a randomised controlled trial
    Izett-Kay, M.
    Rahmanou, P.
    Cartwright, R.
    Price, N.
    Jackson, S.
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2020, 31 (SUPPL 1) : S4 - S5
  • [30] TiRobot-Assisted Percutaneous Cannulated Screw Fixation in the Treatment of Femoral Neck Fractures: A Minimum 2-Year Follow-up of 50 Patients
    Zhu, Zong-dong
    Xiao, Cheng-wei
    Tan, Bo
    Tang, Xiao-ming
    Wei, Dan
    Yuan, Jia-bin
    Hu, Jiang
    Feng, Liao
    ORTHOPAEDIC SURGERY, 2021, 13 (01) : 244 - 252