Folate-Polyethylene Glycol Conjugated Near-Infrared Fluorescence Probe with High Targeting Affinity and Sensitivity for In Vivo Early Tumor Diagnosis

被引:64
|
作者
Liu, Fei [1 ]
Deng, Dawei [1 ]
Chen, Xinyang [1 ]
Qian, Zhiyu [2 ]
Achilefu, Samuel [3 ]
Gu, Yueqing [1 ]
机构
[1] China Pharmaceut Univ, Sch Life Sci & Technol, Dept Biomed Engn, Nanjing 210009, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Sch Automat, Dept Biomed Engn, Nanjing 210016, Peoples R China
[3] Washington Univ, Sch Med, Dept Radiol, St Louis, MO 63110 USA
关键词
Folate; Near-infrared fluorescence imaging; Tumor; Diagnosis; MONOCLONAL-ANTIBODIES; POLYMERIC MICELLE; IMAGING AGENTS; GENE DELIVERY; QUANTUM DOTS; MOUSE MODEL; CANCER; NANOPARTICLES; THERAPY; CELLS;
D O I
10.1007/s11307-010-0305-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to synthesize a folate-polyethylene glycol (PEG) conjugated near-infrared fluorescence probe (fPI-01) for diagnosis of folate receptor (FR)-overexpressed tumors with high sensitivity and specificity. fPI-01 was synthesized, purified, and characterized. Its cytotoxicity and affinity to tumor cells were determined in vitro. The dynamics and biodistribution of the probe was monitored in normal nude mice. And the tumor-targeting capability was investigated in nude mice bearing different tumor xenograft. fPI-01 was successfully synthesized with strengthened optical properties. Cells experiments showed the probe had high FR affinity and without apparent cytotoxicity. Animal experiments indicated the probe excreted through urine by kidney. And its tumor-targeting ability was demonstrated on different tumor-bearing mice, with high sensitivity and tumor-to-normal tissue contrast ratio (10:1). fPI-01 is a promising optical agent for diagnosis of FR-positive tumors, especially in their early stage.
引用
收藏
页码:595 / 607
页数:13
相关论文
共 48 条
  • [31] A ratiometric near-infrared naphthalimide-based fluorescent probe with high sensitivity for detecting Fe2+ in vivo
    Lina Huang
    Yu Chen
    Yuqiang Zhao
    Yumin Wang
    Junwei Xiong
    Junfeng Zhang
    Xianghua Wu
    Ying Zhou
    Chinese Chemical Letters, 2020, 31 (11) : 2941 - 2944
  • [32] A ratiometric near-infrared naphthalimide-based fluorescent probe with high sensitivity for detecting Fe2+ in vivo
    Huang, Lina
    Chen, Yu
    Zhao, Yuqiang
    Wang, Yumin
    Xiong, Junwei
    Zhang, Junfeng
    Wu, Xianghua
    Zhou, Ying
    CHINESE CHEMICAL LETTERS, 2020, 31 (11) : 2941 - 2944
  • [33] Design, Synthesis, and in Vitro and in Vivo Evaluation of High Affinity and Specificity Near-Infrared Fluorescent Bombesin Antagonists for Tumor Imaging
    Xu, Hang
    Bandari, Rajendra P.
    Li Lee
    Li, Ran
    Yu, Ping
    Smith, Charles J.
    Ma, Lixin
    JOURNAL OF MEDICINAL CHEMISTRY, 2018, 61 (17) : 7657 - 7670
  • [34] In Vivo Near-Infrared Fluorescence Imaging of Apoptosis Using Histone H1-Targeting Peptide Probe after Anti-Cancer Treatment with Cisplatin and Cetuximab for Early Decision on Tumor Response
    Jung, Hyun-Kyung
    Wang, Kai
    Jung, Min Kyu
    Kim, In-San
    Lee, Byung-Heon
    PLOS ONE, 2014, 9 (06):
  • [35] In Vivo Near-Infrared Fluorescence Imaging of Integrin α2β1 in Prostate Cancer with Cell-Penetrating- Peptide-Conjugated DGEA Probe
    Huang, Chiun-Wei
    Li, Zibo
    Conti, Peter S.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (12) : 1979 - 1986
  • [36] In Vivo Real-Time Pharmaceutical Evaluations of Near-Infrared II Fluorescent Nanomedicine Bound Polyethylene Glycol Ligands for Tumor Photothermal Ablation
    Li, Shengliang
    Chen, Haoting
    Liu, Haile
    Liu, Lu
    Yuan, Yuan
    Mao, Cong
    Zhang, Wei
    Zhang, Xiaodong
    Guo, Weisheng
    Lee, Chun-Sing
    Liang, Xing-Jie
    ACS NANO, 2020, 14 (10) : 13681 - 13690
  • [37] Bioimaging of glutathione variation for early diagnosis of hepatocellular carcinoma using a liver-targeting ratiometric near-infrared fluorescent probe
    Han, Xiaoyue
    Xing, Yanlong
    Song, Xinyu
    Dou, Kun
    Yu, Fabiao
    Chen, Lingxin
    JOURNAL OF MATERIALS CHEMISTRY B, 2023, 11 (28) : 6612 - 6620
  • [38] Quality analysis of in vivo near-infrared fluorescence and conventional gamma images acquired using a dual-labeled tumor-targeting probe -: art. no. 054010
    Houston, JP
    Ke, S
    Wang, W
    Li, C
    Sevick-Muraca, EM
    JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (05)
  • [39] pH-Activatable tumor-targeting gold nanoprobe for near-infrared fluorescence/CT dual-modal imaging in vivo
    Tang, Yao
    Shi, Hongyuan
    Cheng, Di
    Zhang, Jing
    Lin, Yuncheng
    Xu, Yufang
    Qian, Xuhong
    Zhu, Weiping
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 179 : 56 - 65
  • [40] A "turn-on" near-infrared fluorescent probe with high sensitivity for detecting reduced glutathione based on red shift in vitro and in vivo
    Wang, Kaiping
    Nie, Gang
    Ran, Siqi
    Wang, Huiling
    Liv, Xiqiu
    Zheng, Ziming
    Zhang, Yu
    DYES AND PIGMENTS, 2020, 172