Fast kq-Space Sampling with Motion-Induced Phase in Diffusion MRI

被引:0
|
作者
Pesce, Marica [1 ]
Repetti, Audrey [1 ]
Wiaux, Yves [1 ]
机构
[1] Heriot Watt Univ, Inst Sensors Signals & Syst, Edinburgh EH14 4AS, Midlothian, Scotland
来源
2018 IEEE 10TH SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING WORKSHOP (SAM) | 2018年
基金
英国工程与自然科学研究理事会;
关键词
Diffusion MRI; FOD; kq-space; motion; phase contamination; DECONVOLUTION; ARCHITECTURE; SPARSITY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High spatio-angular resolution diffusion MRI has been shown to provide accurate identification of complex fiber configurations. However, its application in clinics remains limited due to the long required acquisition time. Recently, we have developed a method relying on an accelerated kq-space under-sampling scheme to recover the intra-voxel fiber configurations. In the current work, we generalize our method to consider a more realistic setting. We include into the kq-space measurement model the phase contamination induced by magnetic field inhomogeneities and motion during the signal acquisition. Simulations are performed on realistic synthetic data, considering both the cases when the phase is perfectly known, and when it is pre-calibrated. Results show that, in both the cases, the phase contamination does not penalize the recovery of the fiber configuration.
引用
收藏
页码:420 / 424
页数:5
相关论文
共 50 条
  • [41] Diffusion MRI head motion correction methods are highly accurate but impacted by denoising and sampling scheme
    Cieslak, Matthew
    Cook, Philip A.
    Shafiei, Golia
    Tapera, Tinashe M.
    Radhakrishnan, Hamsanandini
    Elliott, Mark
    Roalf, David R.
    Oathes, Desmond J.
    Bassett, Dani S.
    Tisdall, M. Dylan
    Rokem, Ariel
    Grafton, Scott T.
    Satterthwaite, Theodore D.
    HUMAN BRAIN MAPPING, 2024, 45 (02)
  • [42] Elimination of Motion-Induced Phase Based on Double-Time Switching Scheme for SAA FMCW Radar
    Lin, Yi
    Yang, Kai
    Guo, Min
    Fu, Yunqi
    ELECTRONICS, 2019, 8 (07)
  • [43] Suppressing motion-induced phase error by using equal-step phase-shifting algorithms in fringe projection profilometry
    Wu, Gaoxu
    Yang, Tian
    Liu, Fei
    Qian, Kemao
    OPTICS EXPRESS, 2022, 30 (11) : 17980 - 17998
  • [44] Motion-induced error reduction for phase shifting profilometry using double-shot-in-single-illumination technique
    Suresh, Vignesh
    Wang, Yajun
    Li, Beiwen
    DIMENSIONAL OPTICAL METROLOGY AND INSPECTION FOR PRACTICAL APPLICATIONS VIII, 2019, 10991
  • [45] State-space Model and Analysis of Motion-induced Eddy-current based on Distributed Current Source Method
    Hao, Bingjie
    Liu, Xiaoshu
    Lee, Kok-Meng
    Bai, Kun
    2019 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2019, : 1528 - 1533
  • [46] Real-time motion-induced error compensation for 4-step phase-shifting profilometry
    Guo, Wenbo
    Wu, Zhoujie
    Zhang, Qican
    Wang, Yajun
    OPTICS EXPRESS, 2021, 29 (15) : 23822 - 23834
  • [47] Integrated intravoxel incoherent motion tensor and diffusion tensor brain MRI in a single fast acquisition
    Dietrich, Olaf
    Cai, Mengfei
    Tuladhar, Anil Man
    Jacob, Mina A.
    Drenthen, Gerald S.
    Jansen, Jacobus F. A.
    Marques, Jose P.
    Topalis, Johanna
    Ingrisch, Michael
    Ricke, Jens
    de Leeuw, Frank-Erik
    Duering, Marco
    Backes, Walter H.
    NMR IN BIOMEDICINE, 2023, 36 (07)
  • [48] Assessment of Exposure to MRI Motion-Induced Fields Based on the International Commission on Non-Ionizing Radiation Protection (ICNIRP) Guidelines
    Zilberti, Luca
    Bottauscio, Oriano
    Chiampi, Mario
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1291 - 1300
  • [49] Prevention of Motion-Induced Signal Loss in Diffusion-Weighted Echo-Planar Imaging by Dynamic Restoration of Gradient Moments
    Gumus, Kazim
    Keating, Brian
    Poser, Benedikt A.
    Armstrong, Brian
    Chang, Linda
    Maclaren, Julian
    Prieto, Thomas
    Speck, Oliver
    Zaitsev, Maxim
    Ernst, Thomas
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2006 - 2013
  • [50] A Comparison of Techniques for Correcting Eddy-current and Motion-induced Distortions in Diffusion-weighted Echo-planar Images
    Haneda, Jun
    Hagiwara, Akifumi
    Hori, Masaaki
    Wada, Akihiko
    Fukunaga, Issei
    Murata, Katsutoshi
    Kamagata, Koji
    Fujita, Shohei
    Maekawa, Tomoko
    Irie, Ryusuke
    Takamura, Tomohiro
    Suzuki, Michimasa
    Kumamaru, Kanako Kunishima
    Aoki, Shigeki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (04) : 272 - 275