Fast kq-Space Sampling with Motion-Induced Phase in Diffusion MRI

被引:0
|
作者
Pesce, Marica [1 ]
Repetti, Audrey [1 ]
Wiaux, Yves [1 ]
机构
[1] Heriot Watt Univ, Inst Sensors Signals & Syst, Edinburgh EH14 4AS, Midlothian, Scotland
来源
2018 IEEE 10TH SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING WORKSHOP (SAM) | 2018年
基金
英国工程与自然科学研究理事会;
关键词
Diffusion MRI; FOD; kq-space; motion; phase contamination; DECONVOLUTION; ARCHITECTURE; SPARSITY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High spatio-angular resolution diffusion MRI has been shown to provide accurate identification of complex fiber configurations. However, its application in clinics remains limited due to the long required acquisition time. Recently, we have developed a method relying on an accelerated kq-space under-sampling scheme to recover the intra-voxel fiber configurations. In the current work, we generalize our method to consider a more realistic setting. We include into the kq-space measurement model the phase contamination induced by magnetic field inhomogeneities and motion during the signal acquisition. Simulations are performed on realistic synthetic data, considering both the cases when the phase is perfectly known, and when it is pre-calibrated. Results show that, in both the cases, the phase contamination does not penalize the recovery of the fiber configuration.
引用
收藏
页码:420 / 424
页数:5
相关论文
共 50 条
  • [1] Fast Spatially Coherent Fiber Orientation Estimation in Diffusion MRI from kq-Space Sampling
    Pesce, Marica
    Repetti, Audrey
    Wiaux, Yves
    2019 IEEE 8TH INTERNATIONAL WORKSHOP ON COMPUTATIONAL ADVANCES IN MULTI-SENSOR ADAPTIVE PROCESSING (CAMSAP 2019), 2019, : 326 - 330
  • [2] Fast Fiber Orientation Estimation in Diffusion MRI from kq-Space Sampling and Anatomical Priors
    Pesce, Marica
    Repetti, Audrey
    Auria, Anna
    Daducci, Alessandro
    Thiran, Jean-Philippe
    Wiaux, Yves
    JOURNAL OF IMAGING, 2021, 7 (11)
  • [3] Model for the correction of motion-induced phase errors in multishot diffusion-weighted-MRI of the head: Are cardiac-motion-induced phase errors reproducible from beat-to-beat?
    O'Halloran, R. L.
    Holdsworth, S.
    Aksoy, M.
    Bammer, R.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) : 430 - 440
  • [4] Motion-Induced Phase Error Estimation and Correction in 3D Diffusion Tensor Imaging
    Van, Anh T.
    Hernando, Diego
    Sutton, Bradley P.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (11) : 1933 - 1940
  • [5] Inherent correction of motion-induced phase errors in multishot spiral diffusion-weighted imaging
    Trong-Kha Truong
    Chen, Nan-kuei
    Song, Allen W.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (04) : 1255 - 1261
  • [6] Motion-induced error compensation for phase shifting profilometry
    Liu, Ziping
    Zibley, Peter C.
    Zhang, Song
    OPTICS EXPRESS, 2018, 26 (10): : 12632 - 12637
  • [7] POCS-Enhanced Inherent Correction of Motion-Induced Phase Errors (POCS-ICE) for High-Resolution Multishot Diffusion MRI
    Guo, Hua
    Ma, Xiaodong
    Zhang, Zhe
    Zhang, Bida
    Yuan, Chun
    Huang, Feng
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) : 169 - 180
  • [8] A Potential-Based Formulation for Motion-Induced Electric Fields in MRI
    Zilberti, L.
    Bottauscio, O.
    Chiampi, M.
    IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (03)
  • [9] A NUMERICAL SURVEY OF MOTION-INDUCED ELECTRIC FIELDS EXPERIENCED BY MRI OPERATORS
    Zilberti, Luca
    Chiampi, Mario
    HEALTH PHYSICS, 2013, 105 (06): : 498 - 511
  • [10] Evaluation of Subsurface Defects Using Diffusion of Motion-Induced Eddy Currents
    Rocha, Tiago Jorge
    Ramos, Helena G.
    Ribeiro, Artur Lopes
    Pasadas, Dario Jeronimo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (05) : 1182 - 1187