Design and evaluation of a reflectance diffuse optical tomography system

被引:16
|
作者
Kazanci, Hoseyin Ozgur [1 ]
Mercan, Tanju [1 ]
Canpolat, Murat [1 ]
机构
[1] Akdeniz Univ, Sch Med, Dept Biophys, Biomed Opt Res Unit, TR-07058 Antalya, Turkey
关键词
Reflectance diffuse optical tomography; Optode calibrations; Imaging systems; Medical and biological imaging; BRAIN ACTIVATION; SPATIAL-RESOLUTION; CALIBRATION;
D O I
10.1007/s11082-014-9910-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have designed a continuous wave, back-reflection diffuse optical tomography system; and developed a new practical calibration method including both optode efficiency and positional error corrections. System design, data acquisition and calibration protocols are described in detail. Monte Carlo (MC) simulations of photon distribution for tissue phantoms have been used to obtain the weight matrix to be used in the Rytov approximation to the photon diffusion equation. The system has been evaluated by acquiring data from a tissue phantom with a background scattering coefficient () of and absorption coefficient ( of . An inclusion made of 1 % Intralipid and indocyanine green with and was placed at a 2 cm depth from the tissue phantom surface. After calibration, the average value of the measurements over source-detector pairs at the same distance for each neighborhood was calculated. Perturbation data were obtained by subtracting the average data from the measurements with the same source-detector separation. In the reconstruction, weight matrixes obtained from MC simulation for to were used. The Depth Compensation Algorithm was used in the Tikhonov regularization to identify the location of the inclusion correctly in the reconstruction.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 50 条
  • [41] Combined system of fluorescence diffuse optical tomography and microcomputed tomography for small animal imaging
    Yang, Xiaoquan
    Gong, Hui
    Quan, Guotao
    Deng, Yong
    Luo, Qingming
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (05):
  • [42] Evaluation of a multi-wavelength laser array with diffuse optical tomography
    Ghijsen, Michael
    Zhou, Tiffany
    Thayer, David
    Gun, Baris
    Gulsen, Gultekin
    MULTIMODAL BIOMEDICAL IMAGING V, 2010, 7557
  • [43] Fluorescence diffuse optical tomography: Time-resolved versus continuous-wave in the reflectance configuration
    Ducros, N.
    D'Andrea, C.
    Bassi, A.
    Peyrin, F.
    IRBM, 2011, 32 (04) : 243 - 250
  • [44] Experimental results on time-resolved reflectance diffuse optical tomography with fast-gated SPADs
    Puszka, Agathe
    Di Sieno, Laura
    Dalla Mora, Alberto
    Pifferi, Antonio
    Contini, Davide
    Boso, Gianluca
    Tosi, Alberto
    Planat-Chretien, Anne
    Herve, Lionel
    Koenig, Anne
    Dinten, Jean-Marc
    DIFFUSE OPTICAL IMAGING IV, 2013, 8799
  • [45] A systematic investigation of reflectance diffuse optical tomography using nonlinear reconstruction methods and continuous wave measurements
    Yuan, Zhen
    Zhang, Jiang
    Wang, Xiaodong
    Li, Changqing
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (09): : 3011 - 3022
  • [46] Design of endoscopic optical coherence tomography system
    Yu, DY
    Li, WH
    Wang, Y
    Chen, XD
    ICO20: BIOMEDICAL OPTICS, 2006, 6026
  • [47] Design of optoelectronic system for optical diffusion tomography
    Erakhtin, Igor
    Aristov, Aleksandr
    Novoseltseva, Anna
    Sukhanov, Viktor
    V INTERNATIONAL FORUM FOR YOUNG SCIENTISTS SPACE ENGINEERING, 2017, 102
  • [48] The effect of instrument design on diffuse reflectance measurements
    White, H
    Taylor, J
    AIC: 9TH CONGRESS OF THE INTERNATIONAL COLOUR ASSOCIATION, 2002, 4421 : 761 - 764
  • [49] A Non-Invasive Diffuse Reflectance Optical Spectroscopic Imaging System to Characterize Tissue
    Prince, Shanthi
    Malarvizhi, S.
    SreeHarsha, K. C. Aditya
    Bhandari, Anand
    Dua, Ankit
    2008 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION AND LOGISTICS, VOLS 1-6, 2008, : 77 - 80
  • [50] High performance time-resolved diffuse optical tomography system
    Mo, Weirong
    Chen, Nanguang
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES, 2008, 6849