THEORETICAL AND EXPERIMENTAL ANALYSES OF THE THERMAL RESISTANCE OF A LOOP THERMOSYPHON FOR PASSIVE SOLAR HEATING OF BUILDINGS

被引:1
|
作者
Bellani, Pedro [1 ]
Milanez, Fernando [2 ]
Mantelli, Marcia [1 ]
Filippeschi, Sauro [3 ]
Mameli, Mauro [3 ]
Fantozzi, Fabio [3 ]
机构
[1] Univ Fed Santa Catarina, Dept Mech Engn, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Santa Catarina, Dept Energy Engn, BR-88900000 Ararangua, Brazil
[3] Univ Pisa, Dept Energy Syst Land & Construct Engn, Pisa, Italy
关键词
two-phase loop thermosyphon; thermal resistance; wall thermosyphon; CONDENSATION; PERFORMANCE; EVAPORATION; PIPES;
D O I
10.1615/InterfacPhenomHeatTransfer.2019031160
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study presents experimental and theoretical analyses of the thermal performance of a two-phase copper-R141b loop thermosyphon, which was developed for solar heating of buildings. A prototype of the so-called wall thermosyphon was built and tested at the Heat Pipe Laboratory of the Federal University of Santa Catarina (Labtucal-UFSC). During the tests, three parameters were varied: purge method, power input levels, and inside wall evaporator roughness. The results show that both purge and vacuum pumps are equally effective in eliminating noncondensable gases from the system. Also, recent boiling heat transfer coefficient literature correlations are in good agreement with the experimental data from the prototype. However, the condensation thermal resistance calculated with the literature correlations do not represent the same trend found in the experiments. The effective thermal resistance of the wall thermosyphon prototype, which comprises the boiling resistance plus the condensation resistance, varies between 0.22 and 0.011 degrees C/W depending on the heat transfer rate from 2.5 to 200 W.
引用
收藏
页码:57 / 68
页数:12
相关论文
共 50 条
  • [21] Thermal application of composites of iron and magnesium in thermosyphon solar water heating system
    Sahu, Akash Kumar
    Brahma, Gouri Sankhar
    Aravind, Rudrarapu
    Swain, Trilochan
    HEAT TRANSFER, 2021, 50 (08) : 8617 - 8639
  • [22] Simulation of high thermal mass passive solar buildings
    School of Architecture, University of Auckland, Private Bag 92019, Auckland, New Zealand
    Archit Sci Rev, 2006, 1 (17-29):
  • [23] THERMAL PERFORMANCE OF NONSOUTH WINDOWS IN PASSIVE SOLAR BUILDINGS
    SCHOENAU, G
    SOLAR ENERGY, 1984, 32 (06) : 797 - 799
  • [24] Materials selection for thermal comfort in passive solar buildings
    J. M. Thomas
    S. Algohary
    F. Hammad
    W. O. Soboyejo
    Journal of Materials Science, 2006, 41 : 6897 - 6907
  • [25] Materials selection for thermal comfort in passive solar buildings
    Thomas, J. M.
    Algohary, S.
    Hammad, F.
    Soboyejo, W. O.
    JOURNAL OF MATERIALS SCIENCE, 2006, 41 (21) : 6897 - 6907
  • [26] Experimental investigation of temperature and flow distribution in a thermosyphon solar water heating system
    Chuawittayawuth, K
    Kumar, S
    RENEWABLE ENERGY, 2002, 26 (03) : 431 - 448
  • [27] An Experimental Study of PCM-Incorporated Thermosyphon Solar Water Heating System
    Murali, G.
    Mayilsamy, K.
    Arjunan, T. V.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2015, 12 (09) : 978 - 986
  • [28] Thermal efficiency of insolation passive systems of solar heating
    Dusyarov, A.S.
    Geliotekhnika, 2001, (04): : 32 - 38
  • [29] ON OPTIMAL ZONE HEATING AND ENERGY-CONSERVATION IN PASSIVE SOLAR BUILDINGS
    KIRKPATRICK, A
    WINN, CB
    SOLAR ENERGY, 1986, 36 (05) : 459 - 464
  • [30] A PASSIVE SOLAR HEATING-SYSTEM FOR THE PERIMETER ZONE OF OFFICE BUILDINGS
    GUTHERZ, JM
    SCHILER, ME
    ENERGY SOURCES, 1991, 13 (01): : 39 - 54