Immobilized metal affinity adsorption for antibody depletion from human serum with monosize beads

被引:25
|
作者
Altintas, Evrim Banu
Tuezmen, Nalan
Uzun, Lokman
Denizli, Adil [1 ]
机构
[1] Hacettepe Univ, Div Biochem, Dept Chem, Ankara, Turkey
[2] Dokuzeylul Univ, Div Biochem, Dept Chem, Izmir, Turkey
关键词
D O I
10.1021/ie061164c
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Iminodiacetic acid (IDA)-functionalized adsorbents have attracted increasing interest in recent years for immobilized metal-affinity chromatography (IMAC). In this study, IDA was covalently attached to nonporous monosize poly(glycidyl methacrylate) [poly(GMA)] beads (1.6 mu m in diameter). Cull ions were chelated via IDA groups for affinity depletion of immunoglobulin G (IgG) from human serum. The monosize poly(GMA) beads were characterized by scanning electron microscopy. The Cu2+ -chelated beads (628 mu mol/g) were used in the IgG adsorption - elution studies. Studies to determine the effects of IgG concentration, pH, and temperature on the adsorption efficiency Of Cull -chelated beads were performed in a batch system. Nonspecific binding of IgG to monosize beads in the absence of Cu2+ ions was very low (0.45 mg/g). The IgG adsorption to chelated Cull ions was 171.2 mg/g. The equilibrium IgG adsorption increased with increasing temperature. The negative change in Gibbs free energy (Delta G degrees < 0) indicated that the adsorption of IgG on the Cu2+ - chelated beads was a thermodynamically favorable process. The Delta S and Delta H values were 172.1 J/mol.K and -43.2 kJ/mol, respectively. A significant amount of the adsorbed IgG (up to 97.2%) was eluted in the elution medium containing 1.0 M NaCl in 1 h. The kinetics of the interactions suggest that the interactions could be best represented by a mechanism based on second-order kinetics (k = 9.8 x 10(-5) to 118.9 x 10(-5) g.mg(-1).min(-1)). The adsorption followed the Langmuir isotherm model with monolayer adsorption capacity of 156.2-212.8 mg/g. Consecutive adsorption - elution experiments showed that the Cu2+ -chelated beads can be reused almost without any loss in the IgG adsorption capacity. To test the efficiency of IgG depletion from human serum, proteins in the serum and eluted portion were analyzed by two-dimensional gel electrophoresis. The depletion efficiency for IgG was above 98.2%. Eluted proteins include mainly IgG and a negligible amount of non-albumin proteins such as apo-lipoprotein A1, sero-transferrin, haptoglobulin, and alpha 1-antitrypsin. When anti-HSA-Sepharose adsorbent is used together with our metal-chelated monosize poly(GMA) beads, IgG and HSA can be depleted in a single step.
引用
收藏
页码:7802 / 7810
页数:9
相关论文
共 50 条
  • [41] Antibody Purification from Human Plasma by Metal-Chelated Affinity Membranes
    Yavuz, Handan
    Bereli, Nilay
    Armutcu, Canan
    Yilmaz, Fatma
    Denizli, Adil
    JOURNAL OF APPLIED POLYMER SCIENCE, 2012, 123 (06) : 3476 - 3484
  • [42] Purification of Human Serum Immunoglobulins Using Immobilized Metal Affinity Chromatography with Ethylenediamine Triacetic Acid as Chelating Agent
    Gonzalez-Ortega, Omar
    Guzman, Roberto
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2015, 38 (01) : 74 - 81
  • [43] Comparison of different transition metal ions for immobilized metal affinity chromatography of selenoprotein P from human plasma
    Sidenius, U
    Farver, O
    Jons, O
    Gammelgaard, B
    JOURNAL OF CHROMATOGRAPHY B, 1999, 735 (01): : 85 - 91
  • [44] Equilibrium adsorption of poly(His)-tagged proteins on immobilized metal affinity chromatographic adsorbents
    Yang, Yi-Hsing
    Wu, Tusng-Ta
    Suen, Shing-Yi
    Lin, Sung-Chyr
    BIOCHEMICAL ENGINEERING JOURNAL, 2011, 54 (01) : 1 - 9
  • [45] Affinity purification of metalloprotease from marine bacterium using immobilized metal affinity chromatography
    Li, Shangyong
    Wang, Linna
    Yang, Juan
    Bao, Jing
    Liu, Junzhong
    Lin, Shengxiang
    Hao, Jianhua
    Sun, Mi
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (11) : 2050 - 2056
  • [46] Development and characterization of POROS® affinity depletion cartridges for removal of abundant proteins from human serum.
    Guertin, SR
    Nadler, T
    Wagenfeld, B
    Leung, SM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U144 - U144
  • [47] Immobilized metal affinity chromatography without chelating ligands: Purification of soybean trypsin inhibitor on zinc alginate beads
    Gupta, MN
    Jain, S
    Roy, I
    BIOTECHNOLOGY PROGRESS, 2002, 18 (01) : 78 - 81
  • [48] Separation of Human Protein C from components of transgenic milk using immobilized metal affinity chromatography
    Dave, AS
    Bruley, DF
    OXYGEN TRANSPORT TO TISSUE XXI, 1999, 471 : 639 - 647
  • [49] Adsorption and recovery of immobilized coffee ground beads for silver ions from industrial wastewater
    Jeon, Choong
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2017, 53 : 261 - 267
  • [50] Adsorption behaviors of recombinant proteins on hydroxyapatite-based immobilized metal affinity chromatographic adsorbents
    Lin, Peng-Chih
    Lin, Sung-Chyr
    Hsu, Wen-Hwel
    JOURNAL OF THE CHINESE INSTITUTE OF CHEMICAL ENGINEERS, 2008, 39 (05): : 389 - 398