Evaluating the Differences Between Direct and Indirect Interdependencies and Their Impact on Reliability in Cyber-Power Networks

被引:0
|
作者
Falahati, Bamdad [1 ]
Kahrobaee, Salman [2 ]
Ziaee, Omid [3 ]
Gharghabi, Pedram [4 ]
机构
[1] Schweitzer Engn Labs Inc, Bengaluru, Karnataka, India
[2] Southern Calif Edison, Rosemead, CA USA
[3] ABB Compusharp Inc, Santa Clara, CA USA
[4] Mississippi State Univ, Dept Comp & Elect Engn, Mississippi State, MS USA
关键词
cyber-power network; interdependency; microgrid; smart grid; substation automation system;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With the emergence of smart grids, cyber-power network applications have increased dramatically. A cyber-power system is a type of cyber-physical system where the physical network is the high-voltage power network. In these applications, the cyber network controls, protects and monitors the power system. Without the cyber network and communication system, the efficient and reliable operation of the power network is not possible. Previous studies have subdivided cyber-power dependencies into direct and indirect interdependencies. This paper discusses these two types of interdependencies and compares their impact on power network reliability. The paper also details applications of each interdependency. To better illustrate differences, a numerical case study is presented and results are compared.
引用
收藏
页码:243 / 248
页数:6
相关论文
共 50 条
  • [31] Evaluating the Impact of Transmission Power on QoS in Wireless Mesh Networks
    Noack, Andreas
    Boek, Patrick-Benjamin
    Krueck, Sebastian
    2011 20TH INTERNATIONAL CONFERENCE ON COMPUTER COMMUNICATIONS AND NETWORKS (ICCCN), 2011,
  • [32] DIRECT AND INDIRECT COOPERATION BETWEEN TEMPORAL AND PARIETAL NETWORKS FOR INVARIANT VISUAL RECOGNITION
    OTTO, I
    GRANDGUILLAUME, P
    BOUTKHIL, L
    BURNOD, Y
    GUIGON, E
    JOURNAL OF COGNITIVE NEUROSCIENCE, 1992, 4 (01) : 35 - 57
  • [33] Direct or indirect channel structures. Evaluating the impact of channel governance structure on export performance
    Rambocas, Meena
    Meneses, Raquel
    Monteiro, Carlos
    Brito, Pedro Quelhas
    INTERNATIONAL BUSINESS REVIEW, 2015, 24 (01) : 124 - 132
  • [34] Functional Differences Between Direct and Indirect Striatal Output Pathways in Huntington's Disease
    Galvan, Laurie
    Andre, Veronique M.
    Wang, Elizabeth A.
    Cepeda, Carlos
    Levine, Michael S.
    JOURNAL OF HUNTINGTONS DISEASE, 2012, 1 (01) : 17 - 25
  • [35] Direct and indirect pathways to health behavior: Differences between rational and intuitive probability beliefs
    Janssen, E.
    van Osch, L.
    de Vries, H.
    Lechner, L.
    PSYCHOLOGY & HEALTH, 2012, 27 : 60 - 61
  • [36] Clustering-based reliability assessment of smart grids by fuzzy c-means algorithm considering direct cyber-physical interdependencies and system uncertainties
    Memari, Mehran
    Karimi, Ali
    Hashemi-Dezaki, Hamed
    SUSTAINABLE ENERGY GRIDS & NETWORKS, 2022, 31
  • [37] Direct Current Transformer Impact on the DC Power Distribution Networks
    Barcelos, Renan Pillon
    Dujic, Drazen
    IEEE TRANSACTIONS ON SMART GRID, 2022, 13 (04) : 2547 - 2556
  • [38] STATISTICS OF DAMAGES, OF UNAVAILABILITY AND PERTURBATIONS FOR EVALUATING RELIABILITY OF INTERCONNECTION AND TRANSMISSION POWER NETWORKS OF ENEL
    MACHI, S
    ELETTROTECNICA, 1972, 59 (07): : 791 - &
  • [39] A quantitative analysis of the relationship between congestion and reliability in electric power networks
    Blumsack, Seth
    Lave, Lester B.
    Ilic, Marija
    ENERGY JOURNAL, 2007, 28 (04): : 73 - 100
  • [40] Evaluating the Impact of Low Discrepancy Sequences on the Probabilistic Evaluation of Composite Power System Reliability
    Green, Robert C., II
    Wang, Lingfeng
    Alam, Mansoor
    Singh, Chanan
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,