Wear particle analysis of highly crosslinked polyethylene isolated from a failed total hip arthroplasty

被引:22
|
作者
Minoda, Yukihide [1 ,2 ]
Kobayashi, Akio [2 ]
Sakawa, Akira [1 ]
Aihara, Masaharu [1 ]
Tada, Koichi [1 ]
Sugama, Ryo [2 ]
Iwakiri, Kentaro [2 ]
Ohashi, Hirotsugu [2 ]
Takaoka, Kunio [2 ]
机构
[1] Kansai Rosai Hosp, Dept Orthopaed Surg, Amagasaki, Hyogo 6608511, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Orthopaed Surg, Abeno Ku, Osaka 5458585, Japan
关键词
highly crosslinked polyethylene; in vivo; wear particle; total hip arthroplasty;
D O I
10.1002/jbm.b.31048
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polyethylene wear particles are one of the most important factors affecting the results of total hip arthroplasty (THA). To reduce wear generation and to achieve better long-term results of THA, highly crosslinked polyethylene (HXPE) has recently been introduced and come into wide use. Thus far, however, there have been no reports on in vivo analysis of HXPE wear particles. We isolated HXPE wear particles from periprosthetic tissue of a failed THA and analyzed using scanning electron microscope. The number of particles was 5.33 x 107 g(-1). Particle size (equivalent circle diameter) was 0.66 +/- 0.40 mu m (mean +/- standard error). Aspect ratio and roundness were 1.37 +/- 0.26 and 1.44 +/- 0.67, respectively. All the particles were round shaped, and "fibrills" or "shreds" were not detected. Thus far, this was the first report on in vivo wear particle analysis of HXPE. HXPE generated less, smaller, and rounder particles, compared with the corresponding reported values for particles generated from conventional polyethylene. These characteristics might affect macrophage response, osteolysis, and long-term results of THA with HXPE. (C) 2008 Wiley Periodicals, Inc.
引用
收藏
页码:501 / 505
页数:5
相关论文
共 50 条
  • [21] Does highly cross-linked polyethylene wear less than conventional polyethylene in total hip arthroplasty?
    Glyn-Jones, Sion
    Saac, Sherif
    Hauptfleisch, Jennifer
    McLardy-Smith, Peter
    Murray, David W.
    Singh, Harinderjit
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 337 - 343
  • [22] In Vivo Measurement of Polyethylene Wear in Cementless Total Hip Arthroplasty
    Roth, A.
    Sander, K.
    Layher, F.
    Babisch, J.
    Venbrocks, R.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (01) : 13 - 17
  • [23] Influence of polyethylene creep behavior on wear in total hip arthroplasty
    Penmetsa, JR
    Laz, PJ
    Petrella, AJ
    Rullkoetter, PJ
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (03) : 422 - 427
  • [24] Antioxidant-stabilized highly crosslinked polyethylene in total knee arthroplasty A RETRIEVAL ANALYSIS
    Ponzio, D. Y.
    Weitzler, L.
    deMeireles, A.
    Esposito, C., I
    Wright, T. M.
    Padgett, D. E.
    BONE & JOINT JOURNAL, 2018, 100B (10): : 1330 - 1335
  • [25] FAILED TOTAL HIP ARTHROPLASTY
    Monsef, Jad Bou
    Parekh, Amit
    Osmani, Feroz
    Gonzalez, Mark
    JBJS REVIEWS, 2018, 6 (11) : E3
  • [26] A radiological and laboratory assessment of polyethylene wear in failed total hip replacement
    Bisbinas, I
    Tripsianis, G
    Cunningham, JL
    Learmonth, ID
    HIP INTERNATIONAL, 2006, 16 (01) : 39 - 46
  • [27] Minimum 10-Year Wear Analysis of Highly Cross-Linked Polyethylene in Cementless Total Hip Arthroplasty
    So, Kazutaka
    Goto, Koji
    Kuroda, Yutaka
    Matsuda, Shuichi
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12): : 2224 - 2226
  • [28] Polyethylene wear In Total Hip Arthroplasty -matched pair analysis of ceramic and metal heads
    Ranawat, C. S.
    Rasquinha, V. J.
    Rodriguez, J. A.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 59 - 59
  • [29] Highly Crosslinked Polyethylene Does Not Reduce the Wear in Total Knee Arthroplasty In Vivo Study of Particles in Synovial Fluid
    Hinarejos, Pedro
    Pinol, Ignasi
    Torres, Alberto
    Prats, Eva
    Gil-Gomez, Gabriel
    Puig-Verdie, Lluis
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 1333 - 1337
  • [30] The John Charnley Award: Highly Crosslinked Polyethylene in Total Hip Arthroplasty Decreases Long-term Wear: A Double-blind Randomized Trial
    Glyn-Jones, Sion
    Thomas, Geraint E. R.
    Garfjeld-Roberts, Patrick
    Gundle, Roger
    Taylor, Adrian
    McLardy-Smith, Peter
    Murray, David W.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (02) : 432 - 438