Evaluation of a nitrogen-incorporated tetrahedral amorphous carbon thin film for the detection of tryptophan and tyrosine using flow injection analysis with amperometric detection

被引:20
|
作者
Jarosova, Romana [1 ,2 ]
Rutherford, Joy [1 ]
Swain, Greg M. [1 ]
机构
[1] Michigan State Univ, Dept Chem, 578 S Shaw Lane, E Lansing, MI 48824 USA
[2] Charles Univ Prague, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Albertov 6, Prague 12843 2, Czech Republic
关键词
BORON-DOPED DIAMOND; ENERGY-LOSS SPECTROSCOPY; RANGE ELECTRON-TRANSFER; CATHODIC VACUUM-ARC; TA-C FILMS; LIQUID-CHROMATOGRAPHY; ELECTROCHEMICAL DETECTION; OPTICALLY TRANSPARENT; GLASSY-CARBON; NANOCRYSTALLINE DIAMOND;
D O I
10.1039/c6an01379a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on the analytical performance of a tetrahedral amorphous carbon (ta-C:N) thin-film electrode in flow injection analysis with amperometric detection. Two model redox analytes were used to evaluate the electrode response because of their positive detection potentials and propensity (i.e., reaction products) to adsorb and foul sp(2) carbon electrodes: tyrosine and tryptophan. ta-C:N electrodes are attractive for electroanalytical applications because they possesses many of the excellent properties of boron-doped nanocrystalline diamond (BDD) and they can be deposited at or near room temperature. The results show that the ta-C:N electrode exhibits lower background current and noise than glassy carbon (GC). The electrode was stable microstructurally at the positive potentials used for detection, similar to 1.1 V, of these two amino acids and it exhibited superior analytical detection figures of merit as compared to GC and as good or superior to BDD. The linear dynamic range for both analytes at ta-C:N was from 0.1 to 100 mu mol L-1, the sensitivity was 8-12 mA L mol(-1), the short-term response variability was 1-2%, and the minimum detectable concentration was 89.7 +/- 0.9 nM (18.3 mu g L-1 or 0.46 ng) for tryptophan and 120 +/- 11 nM (21.7 mu g L-1 or 0.54 ng) for tyrosine. The analytical detection figures of merit for these amino acids at GC and BDD are also presented for comparison as is characterization data for the chemical composition and microstructure of the ta-C:N film.
引用
收藏
页码:6031 / 6041
页数:11
相关论文
共 50 条
  • [41] A Simple Flow Injection System for Amperometric Detection of Ascorbic Acid Using Carbon Paste/Copper Schiff Base Composite Electrode
    Kulizic, Mihajlo
    Stankovic, Milan
    Rasic, Marija
    Mijatovic, Aleksandar
    Baosic, Rada
    Lolic, Aleksandar
    CHEMISTRYSELECT, 2023, 8 (48):
  • [42] Determination of sulfite by pervaporation-flow injection with amperometric detection using copper hexacyanoferrate-carbon nanotube modified carbon paste electrode
    Alamo, Lori Shayne T.
    Tangkuaram, Tanin
    Satienperakul, Sakchai
    TALANTA, 2010, 81 (4-5) : 1793 - 1799
  • [43] Simple flow injection for determination of sulfite by amperometric detection using glassy carbon electrode modified with carbon nanotubes-PDDA-gold nanoparticles
    Amatatongchai, Maliwan
    Sroysee, Wongduan
    Chairam, Sanoe
    Nacapricha, Duangjai
    TALANTA, 2015, 133 : 134 - 141
  • [44] Voltammetry and Flow Injection Analysis with Amperometric Detection for Sensitive Sodium Metamizole Determination on Glassy Carbon Electrode Modified with SWCNTs/Nafion
    Rumin, Martyna
    Smajdor, Joanna
    Paczosa-Bator, Beata
    Piech, Robert
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2016, 5 (08) : M3005 - M3011
  • [45] DOUBLE INJECTION ENZYMATIC FLOW-ANALYSIS OF GLUCOSE USING AMPEROMETRIC DETECTION AND AN OXYGEN-PERMEABLE REACTION COIL
    WEN, XW
    KIPTON, H
    POWELL, J
    CHRISTIAN, GD
    RUZICKA, J
    ANALYTICA CHIMICA ACTA, 1991, 249 (02) : 451 - 460
  • [46] Evaluation of Thin Film Microextraction for trace elemental analysis of liquid samples using LIBS detection
    Ripoll, L.
    Navarro-Gonzalez, J.
    Legnaioli, S.
    Palleschi, V.
    Hidalgo, M.
    TALANTA, 2021, 223
  • [47] Amperometric Detection of Allopurinol in Flow-Injection Analysis on Electrodes Modified by Carbon Nanotubes and Mixed-Valence Ruthenium and Iridium Oxides
    L. G. Shaidarova
    I. A. Chelnokova
    G. F. Makhmutova
    A. V. Gedmina
    G. K. Budnikov
    Pharmaceutical Chemistry Journal, 2014, 48 : 537 - 542
  • [48] Flow injection analysis with amperometric detection of polyphenols at carbon nanotube/polyvinylpyrrolidone-modified electrodes as classification tool for white wine varieties
    Moreno, Monica
    Sanchez Arribas, Alberto
    Gonzalez, Laura
    Bermejo, Esperanza
    Zapardiel, Antonio
    Chicharro, Manuel
    MICROCHEMICAL JOURNAL, 2021, 162
  • [49] Amperometric Detection of Allopurinol in Flow-Injection Analysis on Electrodes Modified by Carbon Nanotubes and Mixed-Valence Ruthenium and Iridium Oxides
    Shaidarova, L. G.
    Chelnokova, I. A.
    Makhmutova, G. F.
    Gedmina, A. V.
    Budnikov, G. K.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2014, 48 (08) : 537 - 542
  • [50] FLOW-INJECTION ANALYSIS OF 3 N-SUBSTITUTED PHENOTHIAZINE DRUGS WITH AMPEROMETRIC DETECTION AT A CARBON-FIBER ARRAY ELECTRODE
    BELAL, F
    ANDERSON, JL
    ANALYST, 1985, 110 (12) : 1493 - 1496