摘要
Background: Blood specimens for HIV testing are frequently collected using serum collection tubes. The Aptima HIV-1 RNA Qualitative test, originally approved for diagnostic use as a supplemental test for use with plasma, is now approved for use with serum, and may be used in new laboratory-based HIV testing algorithms which detect acute and established HIV infections. Objectives: To compare the sensitivity of Aptima using serum and plasma specimens from persons with established HIV infection. Study design: Parallel serum and plasma specimens were collected from 325 persons with established HIV-1 infection who had positive immunoassay (IA) and Western blot (WB) results. Samples with negative Aptima results were considered false-negative and were subjected to repeat testing. Aptima sensitivity for serum and plasma was calculated relative to IA and WB, and compared using the McNemar test. Results: The sensitivity of Aptima using serum (97.23%, 95% confidence interval [CI] 94.81-98.73) was similar to that using plasma (97.54%, 95% [CI] 95.21-98.93) p = 1.00. Five of ten specimens initially false-negative on either serum or plasma were reactive on repeat testing. No specimens initially classified as false-negative on both matrices were reactive on both matrices on repeat testing. Conclusions: In specimens from persons with established infections, Aptima performed with similar sensitivity when used with serum or plasma. Using serum for immunoassay screening and supplemental testing may provide added convenience for laboratories. Published by Elsevier B. V.
引用
收藏
页码:S63 / S66
页数:4
相关论文
共 50 条
  • [21] Performance of the Aptima HIV-1 RNA Qualitative Assay with 16-and 32-Member Specimen Pools
    Ethridge, Steven F.
    Hart, Clyde
    Hanson, Debra L.
    Parker, Monica M.
    Sullivan, Timothy J.
    Bennett, Berry
    Stephens, Petrice
    Hilliard, Joslyn
    Patel, Pragna
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (09) : 3343 - 3345
  • [22] Comparative evaluation of the Abbott HIV-1 RealTime™ assay with the Standard Roche COBAS® Amplicor™ HIV-1 Monitor® Test, v1.5 for determining HIV-1 RNA levels in plasma specimens from Pune, India
    Khopkar, Priyanka
    Mallav, Vikas
    Chidrawar, Shweta
    Kulkarni, Smita
    JOURNAL OF VIROLOGICAL METHODS, 2013, 191 (01) : 82 - 87
  • [23] HIV-1 RNA quantification in plasma specimens using nuclisens easyQ HIV-1 V2.0
    Oosterlaken, T.
    van Deursen, P.
    Jurriaans, S.
    Ligeon, V.
    Bertens, L.
    de Jong, J.
    JOURNAL OF CLINICAL VIROLOGY, 2009, 46 : S27 - S27
  • [24] QUANTIFICATION OF HIV-1 RNA IN PLASMA USING NASBA (TM) DURING HIV-1 PRIMARY INFECTION
    VANGEMEN, B
    KIEVITS, T
    SCHUKKINK, R
    VANSTRIJP, D
    MALEK, LT
    SOOKNANAN, R
    HUISMAN, HG
    LENS, P
    JOURNAL OF VIROLOGICAL METHODS, 1993, 43 (02) : 177 - 188
  • [25] Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load
    Mor, Orna
    Gozlan, Yael
    Wax, Marina
    Mileguir, Fernando
    Rakovsky, Avia
    Noy, Bina
    Mendelson, Ella
    Levy, Itzchak
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (11) : 3458 - 3465
  • [26] HIV-1 plasma RNA and risk of HIV-1 transmission
    Lingappa, J. R.
    Hughes, J. P.
    Donnel, D.
    Baeten, J. M.
    Mullins, J. I.
    Campbell, M. S.
    Gray, G. E.
    Essex, M.
    Farquhar, C.
    Rees, H.
    Wald, A.
    Corey, L.
    Celum, C.
    RETROVIROLOGY, 2009, 6
  • [27] Quantitative detection of HIV-1 RNA using NucliSens EasyQ HIV-1 assay
    Yao, J
    Liu, Z
    Ko, LS
    Pan, G
    Jiang, Y
    JOURNAL OF VIROLOGICAL METHODS, 2005, 129 (01) : 40 - 46
  • [28] HIV-1 isolation from plasma specimens
    Costa, CI
    Morgado, MG
    Santos, VGV
    MEMORIAS DO INSTITUTO OSWALDO CRUZ, 1996, 91 (06): : 745 - 746
  • [29] Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece
    Antigoni Katsoulidou
    Chrysoula Rokka
    Catherine Issaris
    Catherine Haida
    Kimon Tzannis
    Vana Sypsa
    Maria Detsika
    Dimitrios Paraskevis
    Angelos Hatzakis
    Virology Journal, 8
  • [30] Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece
    Katsoulidou, Antigoni
    Rokka, Chrysoula
    Issaris, Catherine
    Haida, Catherine
    Tzannis, Kimon
    Sypsa, Vana
    Detsika, Maria
    Paraskevis, Dimitrios
    Hatzakis, Angelos
    VIROLOGY JOURNAL, 2011, 8