The 3D microscopic 'signature' of strain within glacial sediments revealed using X-ray computed microtomography

被引:29
|
作者
Tarplee, Mark F. V. [1 ]
van der Meer, Jaap J. M. [1 ]
Davis, Graham R. [2 ]
机构
[1] Queen Mary Univ London, Sch Geog, Ctr Micromorphol, London E1 4NS, England
[2] Queen Mary Univ London, Barts & London Sch Med & Dent, Inst Dent, London E1 4NS, England
关键词
X-ray computed microtomography; Glacial sediments; Subglacial soft sediment deformation; Sediment rheology; Sediment kinematics; Micromorphology; DEFORMATION BENEATH GLACIERS; SUBGLACIAL SHEAR ZONE; DEBRIS FLOW DEPOSIT; IRISH SEA BASIN; QUANTITATIVE-ANALYSIS; FABRIC MEASUREMENTS; TILL DEFORMATION; CENTRAL GASPESIE; BED DEFORMATION; IMAGE QUALITY;
D O I
10.1016/j.quascirev.2011.05.016
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
X-ray computed microtomography (mu CT), a non-destructive analytical technique, was used to create volumetric three-dimensional (3D) models representing the internal composition and structure of undisturbed pro- and subglacial soft sediment sample plugs for the purposes of identifying and analysing kinematic indicators. The technique is introduced and a methodology is presented addressing specific issues relating to the investigation of unlithified, polymineralic sediments. Six samples were selected based on their proximity to 'type' brittle and ductile deformation structures, or because of their perceived suitability for successful application of the technique. Analysis of a proglacial 'ideal' specimen permitted the 3D geometry of a suite of micro-faults and folds to be investigated and the strain history of the sample reconstructed. The poor contrast achieved in scanning a diamicton of glaciomarine origin is attributable to overconsolidation under normal loading, the sediment demonstrated to have undergone subsequent subglacial deformation. Another overconsolidated diamicton contains an extensive, small scale (<20 mu m) network of fractures delineating a 'marble-bed' structure, hitherto unknown at this scale. A volcanic lithic clast contrasts well with the surrounding matrix in a 'lodgement' till sample containing mu CT (void) and thin-section evidence of clast ploughing. Initial ductile deformation was followed by dewatering of the matrix, which led to brittle failure and subsequent emplacement. Compelling evidence of clast rotation is located in the top of another sample, mu CT analysis revealing that the grain has a proximal decollement surface orientated parallel to the plane of shear. The lenticular morphology of the rotational structure defined suggests an unequal distribution of forces along two of the principal stress axes. The excellent contrast between erratics contained within a sample and the enclosing till highlight the considerable potential of the technique in permitting the rapid (semi-)quantitative analysis of large datasets. The subglacial sample evidence indicates that complex, polyphase (brittle/ductile) deformation histories are common in such diamictic soft sediments and that the local (micro-scale) environment (composition, structure, shear forces and effective pressure) controls rheology. The sediment void ratio is a key indicator of strain. Three of the samples are tentatively placed at different points on the strain cycle for subglacially deforming soft sediment, based on their void ratio, characteristics and distribution. It has been demonstrated that mu CT offers significant potential for elucidating glacial soft sediment kinematics. The ability of the technique to both test a variety of hypotheses pertaining to mechanisms operating within the subglacial environment and evaluate efforts to replicate those processes under controlled, laboratory conditions is therefore discussed along with solutions to the problems encountered within this project. mu CT also permits the seamless linking of analytical techniques applied at the hand specimen (mm), micromorphological (pm-mm), scanning electron microscopy and X-ray diffraction/fluorescence (nm-mu m) scales and the archiving, duplication and dissemination of sample volumetric 3D data. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3501 / 3532
页数:32
相关论文
共 50 条
  • [31] Evaluation of rock anisotropy using 3D X-ray computed tomography
    Yun, Tae Sup
    Jeong, Yeon Jong
    Kim, Kwang Yeom
    Min, Ki-Bok
    ENGINEERING GEOLOGY, 2013, 163 : 11 - 19
  • [32] Characterization of rock microstructure using 3D X-ray computed tomography
    Xue, Huaqing
    Xu, Ruina
    Jiang, Peixue
    Zhou, Shangwen
    Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2015, 47 (06): : 1073 - 1078
  • [33] Computational approach to integrate 3D X-ray microtomography and NMR data
    Lucas-Oliveira, Everton
    Araujo-Ferreira, Arthur G.
    Trevizan, Willian A.
    Fortulan, Carlos A.
    Bonagamba, Tito J.
    JOURNAL OF MAGNETIC RESONANCE, 2018, 292 : 16 - 24
  • [34] Stochastic modelling of 3D fiber structures imaged with X-ray microtomography
    Townsend, Philip
    Larsson, Emanuel
    Karlson, Tomas
    Hall, Stephen A.
    Lundman, Malin
    Bergstrom, Per
    Hanson, Charlotta
    Loren, Niklas
    Geback, Tobias
    Sarkka, Aila
    Roding, Magnus
    COMPUTATIONAL MATERIALS SCIENCE, 2021, 194
  • [35] CHARACTERISATION OF THE 3D PAPER STRUCTURE WITH X-RAY SYNCHROTRON RADIATION MICROTOMOGRAPHY
    du Roscoat, S. Rolland
    Bloch, J-F.
    Thibault, X.
    ADVANCES IN PAPER SCIENCE AND TECHNOLOGY: TRANSACTIONS OF THE 13TH FUNDAMENTAL RESEARCH SYMPOSIUM, VOLS 1-3, 2005, : 901 - 920
  • [36] Strain in a silicon-on-insulator nanostructure revealed by 3D x-ray Bragg ptychography
    Chamard, V.
    Allain, M.
    Godard, P.
    Talneau, A.
    Patriarche, G.
    Burghammer, M.
    SCIENTIFIC REPORTS, 2015, 5
  • [37] Strain in a silicon-on-insulator nanostructure revealed by 3D x-ray Bragg ptychography
    V. Chamard
    M. Allain
    P. Godard
    A. Talneau
    G. Patriarche
    M. Burghammer
    Scientific Reports, 5
  • [38] Effect of scanning and image reconstruction settings in X-ray computed microtomography on quality and segmentation of 3D soil images
    Houston, A. N.
    Schmidt, S.
    Tarquis, A. M.
    Otten, W.
    Baveye, P. C.
    Hapca, S. M.
    GEODERMA, 2013, 207 : 154 - 165
  • [39] Sponge skeletons in 3D:: synchrotron x-ray computed microtomography (μCT) as a tool for functional morphology and taxonomy.
    Nickel, M
    Beckmann, F
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2002, 42 (06) : 1285 - 1285
  • [40] Petrophysical analysis of limestone rocks by nuclear logging and 3D high-resolution X-ray computed microtomography
    Oliveira, M. F. S.
    Lima, I.
    Ferrucio, P. L.
    Abreu, C. J.
    Borghi, L.
    Lopes, R. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 905 - 910