The validity of endurance running performance on the Curve 3TM non-motorised treadmill

被引:22
|
作者
Stevens, Christopher J. [1 ]
Hacene, Jake [1 ]
Wellham, Benjamin [1 ]
Sculley, Dean V. [2 ,3 ]
Callister, Robin [2 ,3 ]
Taylor, Lee [4 ]
Dascombe, Ben J. [1 ,2 ]
机构
[1] Univ Newcastle, Fac Sci & Informat Technol, Appl Sports Sci & Exercise Testing Lab, Ourimbah, NSW 2258, Australia
[2] Univ Newcastle, Prior Res Ctr Phys Act & Nutr, Callaghan, NSW 2308, Australia
[3] Univ Newcastle, Fac Hlth & Med, Sch Biomed Sci & Pharm, Callaghan, NSW 2308, Australia
[4] Univ Bedfordshire, ISPAR, Dept Sport Sci & Phys Act, Appl Sport & Exercise Physiol ASEP Res Grp, Bedford, England
关键词
pacing strategy; performance test; endurance training; exercise physiology; exercise performance; RELIABILITY; PERCEPTION;
D O I
10.1080/02640414.2014.986502
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study aimed to test the validity of a non-motorised treadmill (NMT) for the measurement of self-paced overground endurance running performance. Ten male runners performed randomised 5-km running time trials on a NMT and an outdoor athletics track. A range of physiological and perceptual responses was measured, and foot strike was classified subjectively. Performance time was strongly correlated (r=0.82, ICC=0.86) between running modes, despite running time being significantly longer on the NMT (1264 +/- 124s vs. 1536 +/- 130s for overground and NMT, respectively; P<0.001). End blood lactate concentration and rating of perceived exertion were significantly higher on the NMT compared to overground. Integrated electromyography was significantly lower on the NMT for three muscles (P<0.05), and mean stride rate was also significantly lower on the NMT (P=0.04). Cardiorespiratory responses of heart rate, oxygen uptake and expired air volume demonstrated strong correlations (r=0.68-0.96, ICC=0.75-0.97) and no statistical differences (P>0.05). Runners were consistently slower on the NMT, and as such it should not be used to measure performance over a specific distance. However, the strong correlations suggest that superior overground performance was reflected in relative terms on the NMT, and therefore, it is a valid tool for the assessment of endurance running performance in the laboratory.
引用
收藏
页码:1141 / 1148
页数:8
相关论文
共 42 条
  • [31] Prevalence in running events and running performance of endurance runners following a vegetarian or vegan diet compared to non-vegetarian endurance runners: the NURMI Study
    Wirnitzer, Katharina
    Seyfart, Tom
    Leitzmann, Claus
    Keller, Markus
    Wirnitzer, Gerold
    Lechleitner, Christoph
    Rust, Christoph Alexander
    Rosemann, Thomas
    Knechtle, Beat
    SPRINGERPLUS, 2016, 5
  • [32] The Reliability of Running Performance in a 5km Time Trial on a Non-motorized Treadmill
    Stevens, C. J.
    Hacene, J.
    Sculley, D. V.
    Taylor, L.
    Callister, R.
    Dascombe, B.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2015, 36 (09) : 705 - 709
  • [33] Acute ingestion of hydrogen-rich water does not improve incremental treadmill running performance in endurance-trained athletes
    Ooi, Cheong Hwa
    Ng, Siew Kit
    Omar, Eshaifol Azam
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2020, 45 (05) : 513 - 519
  • [34] VALIDITY AND RELIABILITY OF THE FITBIT FLEX (TM) AND ACTIGRAPH GT3X+ AT JOGGING AND RUNNING SPEEDS
    Jones, Denise
    Crossley, Kay
    Dascombe, Ben
    Hart, Harvi F.
    Kemp, Joanne
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2018, 13 (05): : 860 - 870
  • [35] Novel track field test to determine Vpeak, relationship with treadmill test and 10-km running performance in trained endurance runners
    Manoel, Francisco de A.
    Peserico, Cecilia S.
    Machado, Fabiana A.
    PLOS ONE, 2022, 17 (01):
  • [36] Exercise-induced hypohydration impairs 3 km treadmill-running performance in temperate conditions
    Funnell, Mark P.
    Embleton, Daniel
    Morris, Thomas
    Macrae, Heather Z.
    Hart, Nicholas
    Mazzotta, Tiberio
    Lockyer, William
    Juett, Loris A.
    Mears, Stephen A.
    James, Lewis J.
    JOURNAL OF SPORTS SCIENCES, 2023, 41 (12) : 1171 - 1178
  • [37] Analysis on preferential free running laser wavelength and performance modeling of Tm3+-doped YAP and YLF
    Li, Gang
    Liu, Hongjie
    Lu, Feng
    Wen, Xianlun
    Gu, Yuqiu
    Wang, Yuezhu
    APPLIED OPTICS, 2014, 53 (22) : 4987 - 4996
  • [38] Pattern of the heart rate performance curve in maximal graded treadmill running from 1100 healthy 18-65 Years old men and women: the 4HAIE study
    Birnbaumer, Philipp
    Dostal, Tomas
    Cipryan, Lukas
    Hofmann, Peter
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [39] Reliability and Validity of Predicted Performance in the Severe-Intensity Domain From the 3-Minute All-Out Running Test
    Busso, Thierry
    Lloria-Varella, Jaume
    Sabater-Pastor, Frederic
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2024, 19 (09) : 939 - 942
  • [40] High-performance of optical thermometry based on the non-thermally coupled levels in YVO4: Yb3+/Er3+/Tm3+nanocrystals
    Liu, Haiqing
    Miao, Juhong
    Chen, Siyu
    Shen, Jiayu
    Wei, Song
    Rao, Wei-Feng
    JOURNAL OF LUMINESCENCE, 2024, 270