Thirty-Six Years of Service Experience with a National Population of Gas-Insulated Substations

被引:66
|
作者
Istad, Maren [1 ,2 ]
Runde, Magne [1 ,2 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Elect Power Engn, N-7034 Trondheim, Norway
[2] SINTEF Energy Res, NO-7465 Trondheim, Norway
关键词
Aging; end of life; failure analysis; gas-insulated substations (GIS); reliability; sulfur hexafluoride; switchgear;
D O I
10.1109/TPWRD.2010.2050705
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper shows the result of a failure survey including the entire population of gas-insulated substations in the Norwegian power transmission system. The survey comprises the complete service experience up to now-nearly 12 000 circuit-breaker years. Information about 180 failures has been recorded during 36 years: 77 internal flashovers/arcing faults have occurred, four of which burned through the encapsulation and another six caused the pressure-relief devices to operate. No severe injuries have been recorded. The overall failure rates and their causes are comparable to the findings of other reliability surveys, although the occurrence of severe arcing faults appears to be clearly higher than noticed elsewhere. The 300-kV and 420-kV gas-insulated substations put into service around 1980 have a significant and negative influence on the overall failure rate, whereas a large number of 145-kV substations installed since the early 1990s have proven very reliable. Even though a large portion of the population is above or approaching the designed service life of 30 years, no significant aging problems could be revealed with a basis in the failure statistics.
引用
收藏
页码:2448 / 2454
页数:7
相关论文
共 50 条
  • [41] Persistent truncus arteriosus in a man aged thirty-six years
    Carr, FB
    Goodale, RH
    Rockwell, AEP
    ARCHIVES OF PATHOLOGY, 1935, 19 (06): : 833 - 837
  • [42] Seventy-Five Years Completed and Thirty-Six to Go!
    Foegeding, E. Allen
    JOURNAL OF FOOD SCIENCE, 2014, 79 (08) : III - III
  • [43] Thirty-six years of research on oral surgery and implantology in Vienna
    Pommer, Bernhard
    Haas, Robert
    Mailath-Pokorny, Georg
    Dvorak, Gabriella
    Gruber, Reinhard
    INTERNATIONAL JOURNAL OF STOMATOLOGY & OCCLUSION MEDICINE, 2013, 6 : 1 - 1
  • [44] OVERVOLTAGE PROTECTION OF METAL-CLAD 420 KV GAS-INSULATED SUBSTATIONS
    ROHSLER, H
    STRNAD, A
    ETZ ARCHIV, 1984, 6 (07): : 233 - 238
  • [45] POWER FREQUENCY FIELD TESTING OF GAS-INSULATED SUBSTATIONS BY MAGNETIC POTENTIAL TRANSFORMERS
    PETERSEN, CH
    BRAND, U
    LEIBOLD, AA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (06): : 1759 - 1759
  • [46] ACOUSTIC MONITORING OF PARTIAL DISCHARGES IN GAS-INSULATED SUBSTATIONS USING OPTICAL SENSORS
    COSGRAVE, JA
    VOURDAS, A
    JONES, GR
    SPENCER, JW
    MURPHY, MM
    WILSON, A
    IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1993, 140 (05): : 369 - 374
  • [47] GAS-INSULATED, MEDIUM-VOLTAGE SWITCH DISCONNECTOR PACKAGES FOR TRANSFORMER SUBSTATIONS
    MULLER, GCJ
    BROWN BOVERI REVIEW, 1985, 72 (12): : 586 - 591
  • [48] ELECTROMAGNETIC TECHNIQUES FOR FAULT AND PARTIAL DISCHARGE LOCATION IN GAS-INSULATED CABLES AND SUBSTATIONS
    BOGGS, SA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (07): : 1935 - 1941
  • [49] Influence of HV LC filter on lightning overvoltages in Gas-Insulated Switchgear substations
    Szewczyk, Marcin
    Kuczek, Tomasz
    Stosur, Mariusz
    Piasecki, Wojciech
    Florkowski, Marek
    Fulczyk, Marek
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (5A): : 204 - 207
  • [50] TRANSIENT GROUND POTENTIAL RISE IN GAS-INSULATED SUBSTATIONS - PROBLEM IDENTIFICATION AND MITIGATION
    DICK, EP
    FUJIMOTO, N
    FORD, GL
    HARVEY, S
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (10): : 3610 - 3619