Treatment of radioactive liquid effluents by reverse osmosis membranes: From lab-scale to pilot-scale

被引:48
|
作者
Combernoux, Nicolas [1 ,2 ]
Schrive, Luc [1 ]
Labed, Veronique [1 ]
Wyart, Yvan [2 ]
Carretier, Emilie [2 ]
Moulin, Philippe [2 ]
机构
[1] Commissariat Energie Atom & Energies Alternat, CEA, DEN, DE2D,SEAD, F-30207 Bagnols Sur Ceze, France
[2] Aix Marseille Univ, CNRS, Cent Marseille, UMR 7340 M2P2,EPM,Europole Arbois, BP80,Pavil Laennec,Hall C, F-13545 Aix En Provence, France
关键词
Reverse osmosis membrane; Decontamination process; Radionuclides; Gamma irradiation; DRINKING-WATER; WASTE-WATER; PHYSIOCHEMICAL PROPERTIES; PART II; DESALINATION; REMOVAL; RADIONUCLIDES; POLYAMIDE; RO; RADIOIMMUNOASSAY;
D O I
10.1016/j.watres.2017.06.062
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The recent use of the reverse osmosis (RO) process at the damaged Fukushima-Daiichi nuclear power plant generated a growing interest in the application of this process for decontamination purposes. This study focused on the development of a robust RO process for decontamination of two kinds of liquid effluents: a contaminated groundwater after a nuclear disaster and a contaminated seawater during a nuclear accident. The SW30 HR membrane was selected among other in this study due to higher retentions (96% for Cs and 98% for Sr) in a true groundwater. Significant fouling and scaling phenomenon, attributed to calcium and strontium precipitation, were evidenced in this work: this underscored the importance of the lab scale experiment in the process. Validation of the separation performances on trace radionuclides concentration was performed with similar retention around 96% between surrogates Cs (inactive) and Cs-137 (radioactive). The scale up to a 2.6 m(2) spiral wound membrane led to equivalent retentions (around 96% for Cs and 99% for Sr) but lower flux values: this underlined that the hydrodynamic parameters (flowrate/cross-flow velocity) should be optimized. This methodology was also applied on the reconstituted seawater effluent: retentions were slightly lower than for the groundwater and the same hydrodynamic effects were observed on the pilot scale. Then, ageing of the membrane through irradiation experiments were performed. Results showed that the membrane active layer composition influenced the membrane resistance towards gamma irradiation: the SW30 HR membrane performances (retention and permeability) were better than the Osmonics SE at 1 MGy. Finally, to supplement the scale up approach, the irradiation of a spiral wound membrane revealed a limited effect on the permeability and retention. This indicated that irradiation conditions need to be controlled for a further development of the process. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:311 / 320
页数:10
相关论文
共 50 条
  • [21] Pilot-Scale Treatment of Neutral Pharmaceuticals in Municipal Wastewater Using Reverse Osmosis and Ozonation
    Hollman, Jordan
    Khan, Muhammad Faizan
    Dominic, John Albino
    Achari, Gopal
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2020, 146 (11)
  • [22] Comparative performance of nanofiltration and forward osmosis membranes in a lab-scale forward osmosis membrane bioreactor
    Parveen, Fozia
    Hankins, Nick
    JOURNAL OF WATER PROCESS ENGINEERING, 2019, 28 : 1 - 9
  • [23] Hydrothermal carbonization of medical wastes and lignocellulosic biomass for solid fuel production from lab-scale to pilot-scale
    Shen, Yafei
    Yu, Shili
    Ge, Shun
    Chen, Xingming
    Ge, Xinlei
    Chen, Mindong
    ENERGY, 2017, 118 : 312 - 323
  • [24] Removal of polar organic micropollutants by pilot-scale reverse osmosis drinking water treatment
    Albergamo, Vittorio
    Blankert, Bastiaan
    Cornelissen, Emile R.
    Hofs, Bas
    Knibbe, Willem-Jan
    van der Meer, Walter
    de Voogt, Pim
    WATER RESEARCH, 2019, 148 : 535 - 545
  • [25] An investigation on biological stability of product water generated by lab-scale and pilot-scale distillation systems
    Ong, SL
    Hu, JY
    Ng, WJ
    Wang, L
    Phua, ET
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2002, 77 (03) : 243 - 254
  • [26] Pilot-scale studies on the treatment of tannery effluents by electroflotation
    Raju, G. Bhaskar
    Prabhakar, S.
    Rao, S. Subba
    Gopalakrishna, K.
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2007, 30 (02) : 332 - 344
  • [27] Monitoring local membrane fouling mitigation by fluidized GAC in lab-scale and pilot-scale AnFMBRs
    Wang, Jingwei
    Wu, Bing
    Liu, Yu
    Fane, Anthony G.
    Chew, Jia Wei
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 199 : 331 - 345
  • [28] An Investigation on Biological Stability of Product Water Generated by Lab-scale and Pilot-scale Distillation Systems
    S. L. Ong
    J. Y. Hu
    W. J. Ng
    L. Wang
    E. T. Phua
    Environmental Monitoring and Assessment, 2002, 77 : 243 - 254
  • [29] Nitrate adsorption by multiple biomaterial based resins: Application of pilot-scale and lab-scale products
    Xu, Xing
    Gao, Baoyu
    Yue, Qinyan
    Li, Qian
    Wang, Yan
    CHEMICAL ENGINEERING JOURNAL, 2013, 234 : 397 - 405
  • [30] NOx abatement from stationary emission sources by photo-assisted SCR: Lab-scale to pilot-scale studies
    Yu, Joseph C. C.
    Van-Huy Nguyen
    Lasek, Janusz
    Chiang, Sheng-Wei
    Li, Duan Xing
    Wu, Jeffrey C. S.
    APPLIED CATALYSIS A-GENERAL, 2016, 523 : 294 - 303