Fire Behaviour of Restrained RC Beams with slab

被引:0
|
作者
Tang, Guihe [1 ]
Wu, Bo [1 ]
机构
[1] S China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
来源
ADVANCES IN STRUCTURES, PTS 1-5 | 2011年 / 163-167卷
关键词
Reinforced Concrete; Restrained Beam; Fire Resistance; Slab; Elevated Temperature;
D O I
10.4028/www.scientific.net/AMR.163-167.1445
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Using the computer program SAFIR, the behaviors of restrained reinforced concrete (RC) beams with slab exposed to ISO834 standard fire are analyzed. The influences of three parameters (i.e., width of slab, axial restraint stiffness ratio, and rotational restraint stiffness ratio) on the beams' behaviors in fire are investigated. Simulation results show that: (a) the axial force in the slab is much larger than that in the beam on the whole; (b) after 0.5 hour of heating the axial force in the slab decreases gradually with an increasing of the slab width ranging from 1.0 m to 2.5 m, but the influence of the slab width ranging from 1.0 m to 2.5 m on the axial force in the beam is limited; and (c) the effect of the rotational restraint stiffness ratio on the axial force in the beam/slab is very limited, but the beam's peak hogging moment increases gradually with an increasing of the rotational restraint stiffness ratio.
引用
下载
收藏
页码:1445 / 1450
页数:6
相关论文
共 50 条
  • [21] Fire Resistance of Composite Beams with Restrained Superposed Slabs
    Lyu, Junli
    Chen, Qichao
    Xue, Huizhong
    Cai, Yongyuan
    Lyu, Jingjing
    Zhou, Shengnan
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2020, 2020
  • [23] Coefficient of Moment of Inertia for Ribbed RC Slab Beams
    Kelpsa, Sarunas
    Rinkevicius, Gediminas
    Zingaila, Tadas
    Augonis, Mindaugas
    Kitovas, Vadimas
    MECHANIKA, 2019, 25 (03): : 178 - 186
  • [24] Fire damage of RC slab structure of a shopping center
    Knyziak, Piotr
    Kowalski, Robert
    Krentowski, Janusz R.
    ENGINEERING FAILURE ANALYSIS, 2019, 97 : 53 - 60
  • [25] Fire resistance of RC beams under design fire exposure
    Gao, Wan-Yang
    Teng, Jin-Guang
    Dai, Jian-Guo
    MAGAZINE OF CONCRETE RESEARCH, 2017, 69 (08) : 402 - 423
  • [26] Experimental analysis on flexural behaviour of RC beams strengthened with CFRP laminates and under fire conditions
    Carlos, Thiago B.
    Rodrigues, Joao Paulo C.
    de Lima, Rogerio C. A.
    Dhima, Dhionis
    COMPOSITE STRUCTURES, 2018, 189 : 516 - 528
  • [27] Performance of repaired fire affected RC beams
    Kumar, P. M. V. Udaya
    Raju, M. Potha
    Rao, K. Srinivasa
    CURRENT SCIENCE, 2009, 96 (03): : 398 - 402
  • [28] Reliability Analysis of RC Beams Exposed to Fire
    Eamon, Christopher D.
    Jensen, Elin
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (02) : 212 - 220
  • [29] RELIABILITY OF RC BEAMS SUBJECTED TO FIRE - CLOSURE
    ELLINGWOOD, B
    SHAVER, JR
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1978, 104 (10): : 1677 - 1677
  • [30] Fire Tests on RC Beams Strengthened with NSM
    Palmieri, A.
    Matthys, S.
    Taerwe, L.
    ADVANCES IN FRP COMPOSITES IN CIVIL ENGINEERING, 2010, : 401 - 404