Fire Behaviour of Restrained RC Beams with slab

被引:0
|
作者
Tang, Guihe [1 ]
Wu, Bo [1 ]
机构
[1] S China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
来源
ADVANCES IN STRUCTURES, PTS 1-5 | 2011年 / 163-167卷
关键词
Reinforced Concrete; Restrained Beam; Fire Resistance; Slab; Elevated Temperature;
D O I
10.4028/www.scientific.net/AMR.163-167.1445
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Using the computer program SAFIR, the behaviors of restrained reinforced concrete (RC) beams with slab exposed to ISO834 standard fire are analyzed. The influences of three parameters (i.e., width of slab, axial restraint stiffness ratio, and rotational restraint stiffness ratio) on the beams' behaviors in fire are investigated. Simulation results show that: (a) the axial force in the slab is much larger than that in the beam on the whole; (b) after 0.5 hour of heating the axial force in the slab decreases gradually with an increasing of the slab width ranging from 1.0 m to 2.5 m, but the influence of the slab width ranging from 1.0 m to 2.5 m on the axial force in the beam is limited; and (c) the effect of the rotational restraint stiffness ratio on the axial force in the beam/slab is very limited, but the beam's peak hogging moment increases gradually with an increasing of the rotational restraint stiffness ratio.
引用
下载
收藏
页码:1445 / 1450
页数:6
相关论文
共 50 条
  • [1] Behavior of thermally restrained RC beams in case of fire
    Albuquerque, Gabriela L.
    Silva, Augusto B.
    Rodrigues, Joao Paulo C.
    Silva, Valdir P.
    ENGINEERING STRUCTURES, 2018, 174 : 407 - 417
  • [2] Ultimate torsional behaviour of axially restrained RC beams
    Bernardo, Luis F. A.
    Taborda, Catia S. B.
    Andrade, Jorge M. A.
    COMPUTERS AND CONCRETE, 2015, 16 (01): : 67 - 97
  • [3] Effect of fire on flexural behaviour of RC beams
    ElHawary, MM
    Ragab, AM
    ElAzim, AA
    Elibiari, S
    CONSTRUCTION AND BUILDING MATERIALS, 1996, 10 (02) : 147 - 150
  • [4] A numerical study of the behaviour of restrained RC beams at elevated temperatures
    Wu, B.
    Lu, J. Z.
    FIRE SAFETY JOURNAL, 2009, 44 (04) : 522 - 531
  • [5] Effect of fire on shear behaviour of RC beams
    ElHawary, MM
    Ragab, AM
    ElAzim, AA
    Elibiari, S
    COMPUTERS & STRUCTURES, 1997, 65 (02) : 281 - 287
  • [6] Non-linear fire analysis of restrained curved RC beams
    Ruzic, D.
    Kolsek, J.
    Planinc, I.
    Saje, M.
    Hozjan, T.
    ENGINEERING STRUCTURES, 2015, 84 : 130 - 139
  • [7] Behaviour of axially and rotationally restrained reinforced concrete beams in fire
    Albrifkani, Sherwan
    Wang, Yong C.
    ENGINEERING STRUCTURES, 2020, 213 (213)
  • [8] Experimental investigation of behaviour of axially restrained steel beams in fire
    Liu, TCH
    Fahad, MK
    Davies, JM
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2002, 58 (09) : 1211 - 1230
  • [9] Flexural behaviour of corroded RC beams exposed to fire
    Tariq, Faraz
    Bhargava, Pradeep
    STRUCTURES, 2021, 33 : 1366 - 1375
  • [10] Numerical study on the fire behaviour of restrained steel-concrete composite beams
    Ding, Fa-xing
    Wang, Wenjun
    Jiang, Binhui
    JOURNAL OF BUILDING ENGINEERING, 2023, 70