Combination of Skip-Flat test with Ritchey-Common test for the large rectangular flat

被引:3
|
作者
Zhang Linchao [1 ]
Xuan Bin [1 ]
Xie Jingjiang [1 ]
机构
[1] Chinese Acad Sci, Key Lab Opt Syst Adv Mfg Technol, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
关键词
large flat mirrors; Skip-Flat test; Ritchey-Common test;
D O I
10.1117/12.867490
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The Skip-Flat test and Ritchey-Common test are the well-known methods for large flat mirrors measurement. This paper describes the theories of two methods. The combination of the Skip-Flat test with Ritchey-Common test is proposed. Simulations and experiments of the combination method for testing the large rectangular flat of high aspect ratio are shown. The results of the combination test and direct measurement are presented. In comparison of the methods, the combination test is in good agreement with the direct measurement.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Application of Ritchey-Common test in large flat measurements
    Han, S
    Novak, E
    Schurig, M
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION II: APPLICATIONS IN PRODUCTION ENGINEERING, 2001, 4399 : 131 - 136
  • [2] Local Sampling Ritchey-Common Test for Large Aperture Flat Mirror
    Lin Dongdong
    Hu Mingyong
    Li Jinpeng
    Ding Yaofang
    LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (03)
  • [3] Application of error detaching to Ritchey-Common test for flat mirrors
    Zhu, Shuo
    Zhang, Xiao-Hui
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2014, 22 (01): : 7 - 12
  • [4] Ritchey-Common test for a 1.5 m-diameter flat mirror
    Zhu, S.
    Zhang, X. H.
    JOURNAL OF THE EUROPEAN OPTICAL SOCIETY-RAPID PUBLICATIONS, 2014, 9 : 1 - 5
  • [5] Simulation test research of using the Ritchey-Common method for the detection of large flat mirror
    Zhu, Shuo
    Zhang, Xiaohui
    FRONTIERS OF ADVANCED MATERIALS AND ENGINEERING TECHNOLOGY, PTS 1-3, 2012, 430-432 : 1733 - 1737
  • [6] Study on test the large aperture flat by a smaller standard mirror use the Ritchey-Common method
    Bo, Ji
    Chen, Xu
    PROCEEDINGS OF THE 2014 9TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2014, : 258 - 261
  • [7] The error analyze of testing the large aperture flat by the Ritchey-Common method
    Ji, Bo
    Xu, Chen
    Li, Bo
    INTERNATIONAL SYMPOSIUM ON OPTOELECTRONIC TECHNOLOGY AND APPLICATION 2014: IMAGING SPECTROSCOPY; AND TELESCOPES AND LARGE OPTICS, 2014, 9298
  • [8] Single-test Ritchey-Common interferometry
    Liu, Yiming
    Xu, Chuheng
    Hu, Yao
    Lu, Huiqin
    Li, Jinpeng
    Wu, Tiancheng
    Zhang, Shaohui
    Chang, Xu
    Hao, Qun
    OPTICS EXPRESS, 2024, 32 (01) : 62 - 78
  • [9] USING RITCHEY-COMMON TEST FOR LARGE PLANE MIRRORS (FLATS)
    HOUSTON, JB
    OPTICAL ENGINEERING, 1975, 14 (03) : S88 - S90
  • [10] Ritchey-common test analyzes uncoated optics
    Zecchino, M. (mikez@veeco.com), 1600, Laurin Publishing Co. Inc. (37):