Chemical ionization of carboxylic acids and esters in negative mode selected ion flow tube - Mass spectrometry (SIFT-MS)

被引:4
|
作者
Ghislain, Mylene [1 ]
Reyrolle, Marine [1 ]
Sotiropoulos, Jean-Marc [1 ]
Pigot, Thierry [1 ]
Le Bechec, Mickael [1 ]
机构
[1] Univ Pau & Pays Adour, IPREM, IMT Mines Ales, CNRS,E2S UPPA, Pau, France
关键词
Selected ion flow tube - Mass spectrometry; SIFT-MS; Negative ionization; Volatile fatty acids; Esters; Modeling; VOLATILE ORGANIC-COMPOUNDS; EXHALED BREATH; AIR; VOLATOLOMICS; VOCS; SKIN;
D O I
10.1016/j.microc.2021.106609
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selected ion flow tube - mass spectrometry (SIFT-MS) is based on chemical reactivity of analytes with reactant ions. The complete understanding of all the ion-molecule reactions is the key to the deployment of this technology for the direct and rapid analysis of VOCs in the gas phase. In the present work, we focused on direct analysis of carboxylic acids and esters, compounds involved in many biochemical processes. The ion-molecule reactions of negative precursor ions (OH-, O center dot-, O-2(center dot-), NO2- and NO3-) with 9 carboxylic acids and 21 esters were investigated in order to provide product ions and rate constants for these compounds analysis by SIFT-MS. The modelling of ion-molecule reaction paths by ab-initio calculations supported the experimental results and provided a better understanding of these gas phase ion-molecule reactions. The most common reaction mechanism with all the tested molecules is deprotonation. However, other specific reactivities, leading to the formation of anion-molecule complexes with NO2- and O-2(center dot-) in particular, are observed. Furthermore, specific fragmentations of chemical families are also noticed and confirmed with O-2(center dot-) and O center dot-. Finally, we demonstrated that the composition of the matrix (H2O, CO2) participates in the formation of secondary ions. In this work, we determined the kinetic rate constants in the nitrogen carrier gas and the detection limits of all the compounds with the eight precursor ions used by SIFT-MS, allowing accurate quantification in the gas phase at the ppb level. These results contribute to enlarge the negative ionization SIFT-MS measurements to applications where quantification of organic acids and esters are required.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Development of Real-time and Simultaneous Quantification of Volatile Organic Compounds in Ambient with SIFT-MS (Selected Ion Flow Tube-Mass Spectrometry)
    Son, Hyun Dong
    An, Joon Geon
    Ha, Sung Yong
    Kim, Gi Beum
    Yim, Un Hyuk
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2018, 34 (03) : 393 - 405
  • [42] ESTABLISHING NORMAL VALUES FOR GASTROINTESTINAL HYDROGEN SULPHIDE PRODUCTION IN BREATH USING SELECTED-ION FLOW-TUBE MASS SPECTROMETRY (SIFT-MS)
    Hobson, Anthony
    Bloor, Sarah
    Nagalingam, Nabeetha
    Tawfike, Ahmed
    O'Brien, Brett
    Allsworth, Max
    Boyle, Billy
    GASTROENTEROLOGY, 2023, 164 (06) : S594 - S594
  • [43] Direct analysis of aldehydes and carboxylic acids in the gas phase by negative ionization selected ion flow tube mass spectrometry: Quantification and modelling of ion-molecule reactions
    Ghislain, Mylene
    Costarramone, Nathalie
    Sotiropoulos, Jean-Marc
    Pigot, Thierry
    Van Den Berg, Robin
    Lacombe, Sylvie
    Le Bechec, Mickael
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (21) : 1623 - 1634
  • [44] Determining modified reaction parameters for the real-time measurement of BTEX in biogas and nitrogen using Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)
    Nicholas D. C. Allen
    Mark Perkins
    Thomas Bacquart
    Jianrong Li
    Accreditation and Quality Assurance, 2019, 24 : 361 - 368
  • [45] Determining modified reaction parameters for the real-time measurement of BTEX in biogas and nitrogen using Selected Ion Flow Tube Mass Spectrometry (SIFT-MS)
    Allen, Nicholas D. C.
    Perkins, Mark
    Bacquart, Thomas
    Li, Jianrong
    ACCREDITATION AND QUALITY ASSURANCE, 2019, 24 (05) : 361 - 368
  • [46] Single Breath Exhaled Gas Analysis by Selected Ion-Flow Tube Mass-Spectrometry (SIFT-MS) in Patients with Acute Decompensated Heart Failure
    Samara, Michael A.
    Paschke, Kelly M.
    Tang, W. H. Wilson
    Dweik, Raed A.
    JOURNAL OF CARDIAC FAILURE, 2011, 17 (08) : S4 - S4
  • [47] Analysis of Factors Affecting Volatile Compound Formation in Roasted Pumpkin Seeds with Selected Ion Flow Tube-Mass Spectrometry (SIFT-MS) and Sensory Analysis
    Bowman, T.
    Barringer, S.
    JOURNAL OF FOOD SCIENCE, 2012, 77 (01) : C51 - C60
  • [48] Mobile selected ion flow tube mass spectrometry (SIFT-MS) devices and their use for pollution exposure monitoring in breath and ambient air-pilot study
    Storer, Malina
    Salmond, Jennifer
    Dirks, Kim N.
    Kingham, Simon
    Epton, Michael
    JOURNAL OF BREATH RESEARCH, 2014, 8 (03)
  • [49] Study of the Chemical Ionization of Organophosphate Esters in Air Using Selected Ion Flow Tube-Mass Spectrometry for Direct Analysis
    Ghislain, Mylene
    Reyrolle, Marine
    Sotiropoulos, Jean-Marc
    Pigot, Thierry
    Plaisance, Herve
    Le Bechec, Mickael
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2022, 33 (05) : 865 - 874
  • [50] Investigation of C3-C10 aldehydes in the exhaled breath of healthy subjects using selected ion flow tube-mass spectrometry (SIFT-MS)
    Huang, Juzheng
    Kumar, Sacheen
    Hanna, George B.
    JOURNAL OF BREATH RESEARCH, 2014, 8 (03)