A steady-state method for determining the dealloying critical potential

被引:39
|
作者
Dursun, A [1 ]
Pugh, DV [1 ]
Corcoran, SG [1 ]
机构
[1] Virginia Polytech Inst & State Univ, Blacksburg, VA 24061 USA
关键词
D O I
10.1149/1.1588111
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We show that the commonly accepted measurement of the critical potential for alloy dissolution calculated based on extrapolation of anodic polarization data results in an overestimation of this quantity. A series of constant applied potential experiments prove to be a more accurate method for critical potential determination. For the system Ag0.7Au0.3 in 0.1 M HClO4, we find that the true critical potential lies between 0.990-1.020 V vs. normal hydrogen electrode. This is approximately 115 mV below that conventionally determined by anodic polarization data. (C) 2003 The Electrochemical Society.
引用
收藏
页码:B32 / B34
页数:3
相关论文
共 50 条
  • [41] Dealloying below the critical potential
    Wagner, K
    Brankovic, SR
    Dimitrov, N
    Sieradzki, K
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1997, 144 (10) : 3545 - 3555
  • [42] Critical assessment of the microwave method for measuring steady-state and transient regression rates of solids
    Zarko, VE
    Perov, VV
    Simonenko, VN
    COMBUSTION OF ENERGETIC MATERIALS, 2002, : 725 - 732
  • [43] A MODEL FOR DETERMINING THE STEADY-STATE FLUX OF INORGANIC MICROFILTRATION MEMBRANES
    ASAADI, M
    WHITE, DA
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1992, 48 (01): : 11 - 16
  • [44] METHOD FOR DETERMINING STEADY-STATE TEMPERATURE DISTRIBUTION IN WINDING DISKS OF OIL-COOLED TRANSFORMERS
    IMRE, L
    DANKO, G
    PERIODICA POLYTECHNICA-ELECTRICAL ENGINEERING, 1976, 20 (02): : 89 - 102
  • [45] Determination of Critical Micellar Aggregation Numbers of Surfactant by Steady-state Fluorescence Probe Method
    Shag Guoquan
    Yang Zhanzhao
    Wang Min
    Zhao Qiwen
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON ASIAN-EUROPEAN ENVIRONMENTAL TECHNOLOGY AND KNOWLEDGE TRANSFER, 2008, : 420 - 423
  • [46] Determination of critical micellar aggregation numbers of CTTTA by steady-state fluorescence probe method
    Li, XB
    Xu, L
    Meng, XW
    Han, ZH
    Luo, TL
    Liu, GJ
    ACTA PHYSICO-CHIMICA SINICA, 2005, 21 (12) : 1403 - 1406
  • [47] REACTANT FLUXES IN THE STEADY-STATE - THE RATE-DETERMINING STEP
    KING, EL
    JOURNAL OF CHEMICAL EDUCATION, 1991, 68 (11) : 897 - 901
  • [48] A sequential procedure for determining a truncation point in steady-state simulation
    Lee, YH
    Oh, HS
    CRITICAL TECHNOLOGY: PROCEEDINGS OF THE THIRD WORLD CONGRESS ON EXPERT SYSTEMS, VOLS I AND II, 1996, : 510 - 519
  • [49] Method for control of NPP steady-state operation
    Kolesnikov, A
    ANNUAL MEETING ON NUCLEAR TECHNOLOGY '98, PROCEEDINGS, 1998, : 451 - 452
  • [50] Method for the deconvolution of auditory steady-state responses
    Sparacino, G
    Nale, A
    Santarelli, R
    Arslan, E
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (04) : 569 - 576