Reliability of a novel wearable device to measure chewing frequency

被引:10
|
作者
Hori, Kazuhiro [1 ,2 ]
Uehara, Fumiko [1 ,2 ]
Yamaga, Yoshio [1 ,2 ]
Yoshimura, Shogo [1 ,2 ]
Okawa, Jumpei [1 ,2 ]
Tanimura, Motoki [3 ]
Ono, Takahiro [1 ,2 ]
机构
[1] Niigata Univ, Fac Dent, Div Comprehens Prosthodont, 2-5274 Gakkocho Dori, Niigata 9518514, Japan
[2] Niigata Univ, Grad Sch Med & Dent Sci, 2-5274 Gakkocho Dori, Niigata 9518514, Japan
[3] Sharp Co Ltd, Niigata, Japan
关键词
Chewing; Wearable device; Chewing frequency; Reliability; Smartphone; PEDOMETER ACCURACY; FOOD; WEIGHT; SPEED;
D O I
10.2186/jpr.JPR_D_20_00032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: In recent years, the chewing frequency, i.e., the number of chewing cycles, has decreased owing to changes in dietary habits. Although these changes may be related to complete body health, there is no evidence-based tool to measure the dietary habits. We developed a small ear-hung wearable device for monitoring mastication behavior. The device, worn on the ear pinna, allows the counting of the number of chewing cycles, and data are collected on a smartphone via Bluetooth. In this study, the reliability of the novel device was verified. Methods: A total of 22 healthy volunteers participated in the study. During measurement, the subjects wore the novel wearable device on their right ear pinna and were asked to chew gum, gummy jellies, and rice balls. The number of chewing cycles was counted by the device. A mandibular kinesiograph (MKG) was also recorded, and the chewing activity was recorded as a video. The accuracy, precision, and recall of the ear-hung device were calculated by comparing the data obtained from the MKG and the video recording. Additionally, the factors affecting reliability were examined. Results: The accuracy, precision, and recall of the novel device were 101.6 +/- 13.6%, 85.3 +/- 11.0%, and 84.5 +/- 9.5%, respectively. Although the accuracy was not affected by any factor, precision and recall of the novel device for women were significantly worse than that for men, and were greatest when the subjects were chewing gum. Conclusions: Our findings suggest that the newly developed ear-hung wearable device for counting the number of chewing cycles was sufficiently reliable.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 50 条
  • [31] Novel wearable sensor device methodology for STEMI detection
    Fernandez, F.
    Villagran, C.
    Cardenas, G.
    Niklitschek, S.
    Mehta, S.
    Vieira, D.
    Frauenfelder, A.
    Quintero, S.
    Vijayan, Y.
    Merchant, S.
    Tamayo, C. J.
    EUROPEAN HEART JOURNAL, 2020, 41 : 3438 - 3438
  • [32] The validity of a novel wearable device for estimating sleep onset
    Scott, H.
    Lack, E. L.
    Lovato, N.
    JOURNAL OF SLEEP RESEARCH, 2018, 27
  • [33] A Novel Wearable Sensing Device Enabling Remote Palpation
    Pompilio, Michele
    D'Aurizio, Nicole
    Baldi, Tommaso Lisini
    Franco, Leonardo
    Gabriele, Guido
    Prattichizzo, Domenico
    2024 IEEE HAPTICS SYMPOSIUM, HAPTICS 2024, 2024, : 149 - 156
  • [34] A Novel Wearable Sensing Device Enabling Remote Palpation
    Pompilio, Michele
    D'Aurizio, Nicole
    Baldi, Tommaso Lisini
    Franco, Leonardo
    Gabriele, Guido
    Prattichizzo, Domenico
    2024 IEEE SOUTHWEST SYMPOSIUM ON IMAGE ANALYSIS AND INTERPRETATION, SSIAI, 2024, : 149 - 156
  • [35] Harnessing the Ambient Radio Frequency Noise for Wearable Device Pairing
    Jin, Wenqiang
    Li, Ming
    Murali, Srinivasan
    Guo, Linke
    CCS '20: PROCEEDINGS OF THE 2020 ACM SIGSAC CONFERENCE ON COMPUTER AND COMMUNICATIONS SECURITY, 2020, : 1135 - 1148
  • [36] Development of a wearable multi-frequency impedance cardiography device
    Weyer, Sören
    Menden, Tobias
    Leicht, Lennart
    Leonhardt, Steffen
    Wartzek, Tobias
    Journal of Medical Engineering and Technology, 2015, 39 (02): : 131 - 137
  • [37] A Novel Wearable Vibro-tactile Haptic Device
    Ninu, Andrei
    Dosen, Strahinja
    Farina, Dario
    Rattay, Frank
    Dietl, Hans
    2013 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2013, : 51 - +
  • [38] A novel measure to analyse the reliability of LED luminaires
    Padmasali, A. N.
    Kini, S. G.
    LIGHTING RESEARCH & TECHNOLOGY, 2019, 51 (07) : 1063 - 1076
  • [39] Reliability of Wearable Inertial Measurement Units to Measure Physical Activity in Team Handball
    Luteberget, Live S.
    Holme, Benjamin R.
    Spencer, Matt
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2018, 13 (04) : 467 - 473
  • [40] Reliability of a new device to measure medial column hyperlaxity of the foot
    Reymond, Nils
    Kutaish, Halah
    Praz, Quentin
    Drittenbass, Lisca
    As-Sal, Mathieu
    SWISS MEDICAL WEEKLY, 2022, 152 : 20S - 20S