Reliability of a novel wearable device to measure chewing frequency

被引:10
|
作者
Hori, Kazuhiro [1 ,2 ]
Uehara, Fumiko [1 ,2 ]
Yamaga, Yoshio [1 ,2 ]
Yoshimura, Shogo [1 ,2 ]
Okawa, Jumpei [1 ,2 ]
Tanimura, Motoki [3 ]
Ono, Takahiro [1 ,2 ]
机构
[1] Niigata Univ, Fac Dent, Div Comprehens Prosthodont, 2-5274 Gakkocho Dori, Niigata 9518514, Japan
[2] Niigata Univ, Grad Sch Med & Dent Sci, 2-5274 Gakkocho Dori, Niigata 9518514, Japan
[3] Sharp Co Ltd, Niigata, Japan
关键词
Chewing; Wearable device; Chewing frequency; Reliability; Smartphone; PEDOMETER ACCURACY; FOOD; WEIGHT; SPEED;
D O I
10.2186/jpr.JPR_D_20_00032
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: In recent years, the chewing frequency, i.e., the number of chewing cycles, has decreased owing to changes in dietary habits. Although these changes may be related to complete body health, there is no evidence-based tool to measure the dietary habits. We developed a small ear-hung wearable device for monitoring mastication behavior. The device, worn on the ear pinna, allows the counting of the number of chewing cycles, and data are collected on a smartphone via Bluetooth. In this study, the reliability of the novel device was verified. Methods: A total of 22 healthy volunteers participated in the study. During measurement, the subjects wore the novel wearable device on their right ear pinna and were asked to chew gum, gummy jellies, and rice balls. The number of chewing cycles was counted by the device. A mandibular kinesiograph (MKG) was also recorded, and the chewing activity was recorded as a video. The accuracy, precision, and recall of the ear-hung device were calculated by comparing the data obtained from the MKG and the video recording. Additionally, the factors affecting reliability were examined. Results: The accuracy, precision, and recall of the novel device were 101.6 +/- 13.6%, 85.3 +/- 11.0%, and 84.5 +/- 9.5%, respectively. Although the accuracy was not affected by any factor, precision and recall of the novel device for women were significantly worse than that for men, and were greatest when the subjects were chewing gum. Conclusions: Our findings suggest that the newly developed ear-hung wearable device for counting the number of chewing cycles was sufficiently reliable.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 50 条
  • [1] The reliability of a real time wearable sensing device to measure vertical jump
    Mahmoud, Islam
    Othman, Ayman Ali Ahmed
    Abdelrasoul, Emad
    Stergiou, Pro
    Katz, Larry
    IMPACT OF TECHNOLOGY ON SPORT VI' 7TH ASIA-PACIFIC CONGRESS ON SPORTS TECHNOLOGY, APCST2015, 2015, 112 : 467 - 472
  • [2] Demo: Chewpin: a wearable acoustic device for chewing
    Chen, Yang
    Cui, Zhitong
    Yen, Ching Chiuan
    UBICOMP/ISWC '21 ADJUNCT: PROCEEDINGS OF THE 2021 ACM INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND UBIQUITOUS COMPUTING AND PROCEEDINGS OF THE 2021 ACM INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, 2021, : 11 - 12
  • [3] Reliability and Validity of a Novel Wearable Device for Measuring Elbow Strength
    Brookshaw, Marcus
    Sexton, Andrew
    McGibbon, Chris A.
    SENSORS, 2020, 20 (12) : 1 - 16
  • [4] The reliability and validity of a novel wearable inertial sensor to measure the cervical proprioception
    Wang, Jialin
    Wang, Ruirui
    Zhao, Peng
    Han, Tianran
    Cui, Xinwen
    He, Yuwei
    Li, Meng
    MEDICAL ENGINEERING & PHYSICS, 2024, 125
  • [5] VALIDITY AND RELIABILITY OF THE PUSH WEARABLE DEVICE TO MEASURE MOVEMENT VELOCITY DURING THE BACK SQUAT EXERCISE
    Balsalobre-Fernandez, Carlos
    Kuzdub, Matt
    Poveda-Ortiz, Pedro
    del Campo-Vecino, Juan
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (07) : 1968 - 1974
  • [6] A novel approach for chewing detection based on a wearable PPG sensor
    Papapanagiotou, Vasileios
    Diou, Christos
    Zhou, Lingchuan
    van den Boer, Janet
    Mars, Monica
    Delopoulos, Anastasios
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 6485 - 6488
  • [7] Development of the Wearable Device to Measure a Floor Reacting Force
    Fukunaga, Michihiko
    Ichinose, Hayato
    Ishizaka, Shogo
    2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [8] Wearable device to measure disease severity in cervical dystonia
    Rafee, Shameer
    Fitzgerald, Tom
    Hutchinson, Michael
    Reilly, Richard
    NEUROLOGY, 2023, 100 (17)
  • [9] Wearable Device To Measure Heart Beat using IoT
    Jayanth, S.
    Poorvi, M. B.
    Shreyas, R.
    Padmaja, B.
    Sunil, M. P.
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON INVENTIVE SYSTEMS AND CONTROL (ICISC 2017), 2017, : 311 - 315
  • [10] The Reliability Of The IMU-based Wearable Real-time Device To Measure Standing Long Jump For Preschoolers
    Lin, Jui-Chi
    Lin, Linda Li-chuan
    Li, Chih-Yi
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 971 - 972