Mechanical comparison of biplanar proximal closing wedge osteotomy with plantar plate fixation versus crescentic osteotomy with screw fixation for the correction of metatarsus primus varus

被引:35
|
作者
Campbell, JT [1 ]
Schon, LC [1 ]
Parks, BG [1 ]
Wang, YB [1 ]
Berger, BI [1 ]
机构
[1] Union Mem Hosp, Dept Orthopaed Surg, Baltimore, MD USA
关键词
D O I
10.1177/107110079801900505
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Proximal crescentic metatarsal osteotomy is a clinically successful technique for correcting metatarsus primus varus in hallux valgus surgery. However, there have been instances of dorsal elevation of the metatarsal head with this technique. Mechanical testing on 10 matched pairs of cadaver feet was performed to evaluate a new technique combining a biplanar closing wedge osteotomy and plantar plate fixation versus crescentic metatarsal osteotomy. The specimens were tested in cantilever-bending mode on an MTS Mini Bionix test frame. The mean load-to-failure values were 127.2 +/- 81.9 N (SD) for biplanar osteotomy with plate fixation and 44.9 +/- 43.3 N for crescentic osteotomy (P = 0.019); the mean stiffness values at the initial portion of the load-deflection curve were 83.11 +/- 73.76 N/mm and 31.95 +/- 43.00 N/mm, respectively (P = 0.012). The biplanar wedge osteotomy with plantar plate fixation demonstrated significantly stronger fixation than the crescentic osteotomy, with higher mean load-to-failure and stiffness values. this newly described technique may provide an acceptable alternative for patients at risk for dorsal elevation of the metatarsal, particularly those who are noncompliant or have osteopenia. Clinical study will determine whether this new technique offers satisfactory long-term results.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 50 条
  • [41] Surgical correction of cubitus varus in children with a lateral closing-wedge osteotomy: a comparison between two different techniques
    Masquijo, Javier
    Artigas, Cristian
    Hernandez Bueno, Juan Carlos
    Sepulveda, Matias
    Soni, Jamil
    Valenza, Weverley
    Fazal, Faris
    Shah, Apurva S.
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2024, 33 (02): : 167 - 173
  • [42] Comparison of double screw fixation versus tension-band fixation after olecranon osteotomy for complex distal humerus fractures
    Dumartinet-Gibaud, Raphaelle
    Lancigu, Romain
    Hermine, Pierre De Sainte
    Cronier, Patrick
    Hubert, Laurent
    Rony, Louis
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (02)
  • [43] Correction to: Opening‑ and closing‑wedge high tibial osteotomy are comparable and early full weight bearing is safe with angular stable plate fixation: a meta‑analysis
    M. H. van Haeringen
    P. P. F. M. Kuijer
    J. G. Daams
    R. C. I. van Geenen
    J. M. Brinkman
    G. M. M. J. Kerkhoffs
    R. J. van Heerwaarden
    A. Hoorntje
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 3027 - 3027
  • [44] Axial correction of pes varus by transverse-opening wedge osteotomy and T-plate fixation with beta-tricalcium phosphate (β-TCP) transplantation in dachshunds
    Izumisawa, Y
    Seno, T
    Abe, R
    Miyoshi, K
    Maehara, S
    Wakaiki, S
    Kushiro, T
    Umar, MA
    Tsuzuki, K
    Yamashita, K
    Hayashi, S
    [J]. JOURNAL OF VETERINARY MEDICAL SCIENCE, 2005, 67 (04): : 437 - 440
  • [45] Assessment of the Initial Result of Screw Fixation for Proximal Crescentic Metatarsal Osteotomy with Distal Soft Tissue Reconstruction in Severe Hallux Valgus Treatment
    Wang, Linger
    Yao, Liwei
    Dong, Wenwei
    Mao, Haijiao
    [J]. CURRENT MEDICAL IMAGING, 2024, 20
  • [46] Comparison of Bioabsorbable Magnesium versus Titanium Screw Fixation for Modified Distal Chevron Osteotomy in Hallux Valgus
    Acar, Baver
    Kose, Ozkan
    Turan, Adil
    Unal, Melih
    Kati, Yusuf Alper
    Guler, Ferhat
    [J]. BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [47] Tibial Tubercle-Sparing Anterior Closing Wedge Osteotomy With Cross-Screw Fixation to Correct Pathologic Posterior Tibial Slope
    Cruz, Christian A.
    Harris, Mitchell C.
    Wake, Jeffery L.
    Lause, Gregory E.
    Mannino, Brian J.
    Bottoni, Craig R.
    [J]. ARTHROSCOPY TECHNIQUES, 2021, 10 (03): : E897 - E902
  • [48] Analysis and comparison of clinical results of bilateral sagittal split ramus osteotomy performed with the use of monocortical locking plate fixation or bicortical screw fixation
    Kabasawa, Yuhji
    Sato, Masaru
    Kikuchi, Tsuyoshi
    Sato, Yuriko
    Takahashi, Yukiko
    Higuchi, Yusuke
    Omura, Ken
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (05): : E333 - E341
  • [49] Fixation stability of opening- versus closing-wedge high tibial osteotomy A RANDOMISED CLINICAL TRIAL USING RADIOSTEREOMETRY
    Luites, J. W. H.
    Brinkman, J. -M.
    Wymenga, A. B.
    van Heerwaarden, R. J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (11): : 1459 - 1465
  • [50] Radiologic results of additional single screw fixation with lateral locking plate after hybrid closed-wedge high tibial osteotomy
    Hiraoka, Nobuyuki
    Nakagawa, Shuji
    Otakara, Eigo
    Inoue, Hiroaki
    Takahashi, Kenji
    Arai, Yuji
    [J]. KNEE SURGERY & RELATED RESEARCH, 2020, 32 (01)