Diagnostic accuracy of point-of-care ultrasound (PoCUS) for shoulder dislocations and reductions in the emergency department: a diagnostic randomised control trial (RCT)

被引:7
|
作者
Biancardi, Mark Anthony Attard [1 ]
Jarman, Robert David [2 ]
Cardona, Tania [3 ]
机构
[1] Mater Dei Hosp, Emergency Dept, MSD-2090 Msida, Malta
[2] Royal Victoria Infirm, Emergency Med, Newcastle Upon Tyne, Tyne & Wear, England
[3] Mater Dei Hosp, Dept Policy Hlth Hlth Informat & Res, Msida, Malta
关键词
SAMPLE-SIZE; MANAGEMENT; ULTRASONOGRAPHY; RADIOGRAPHS;
D O I
10.1136/emermed-2020-210947
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Following blunt trauma, diagnosis of shoulder dislocation based on physical examination alone is difficult due to possible concurrent proximal humeral fractures. X-rays are therefore used to confirm diagnosis. Results from recent observational studies comparing diagnostic accuracy of point-of-care ultrasound (PoCUS) with X-rays for shoulder dislocation have been encouraging. The aim of this study was to determine whether PoCUS improves diagnostic accuracy when used with physical examination for the diagnosis of shoulder dislocation, proximal humeral fracture and ascertaining successful reduction in the ED. Methods A prospective, single-centre, open, parallel randomised control study over a 6-month period was used to answer the research question and test the null hypothesis. Consecutive eligible adult patients attending the ED of Mater Dei Hospital in Malta were randomised to either the control (C) (physical examination only) or experimental group (E) (physical examination and a two-point PoCUS scan). The study objectives were to measure diagnostic accuracy for both examinations for detecting shoulder dislocation, any associated proximal humeral fractures and confirming reduction. X-rays were used as reference standard for both groups. Results 1206 patients were enrolled in this study (C n=600, E n=606). 290 dislocations (C n=132 and E n=158), 332 proximal humeral fractures (C n=154 and E n=178) and 278 reductions (C n=130 and E n=148) were analysed. A statistically significant difference (p<0.001) was found between the two groups for diagnostic accuracy in shoulder dislocation (C=65%, likelihood ratio (LR)+=2.03 and LR-=0.35 and E=100%, LR+=infinity and LR-=0), proximal humeral fractures (C=45.7%, LR+=1.23 and LR-=0.52 and E=98.3%, LR+=103.9 and LR-=0.03) and reduction (C=68.7%, E=100%). The null hypothesis for this study was thus rejected. Conclusions The addition of PoCUS to a physical examination significantly improves diagnostic accuracy for dislocations, proximal humeral fractures and reduction confirmation.
引用
收藏
页码:655 / U139
页数:7
相关论文
共 50 条
  • [41] Diagnostic point-of-care ultrasound (POCUS) for gastrointestinal pathology: state of the art from basics to advanced
    Abu-Zidan, Fikri M.
    Cevik, Arif Alper
    WORLD JOURNAL OF EMERGENCY SURGERY, 2018, 13
  • [42] Recommendations for developing a comprehensive point-of-care ultrasound (POCUS) program in the emergency department: an Emergency Medicine Ultrasound Group advocacy statement
    Phillips, Luke
    Maclean, Alastair
    Monester, Josh
    Douglas, Joanne
    Davidson, Stacey
    King, Gabriela
    EMERGENCY MEDICINE AUSTRALASIA, 2024, 36 (06) : 956 - 963
  • [43] Diagnostic Accuracy of Point-of-Care Ultrasound for Intussusception: A Multicenter, Noninferiority Study of Paired Diagnostic Tests
    Bergmann, Kelly R.
    Arroyo, Alexander C.
    Tessaro, Mark O.
    Nielson, Jonathan
    Whitcomb, Valerie
    Madhok, Manu
    Yock-Corrales, Adriana
    Guerrero-Quesada, German
    Chaudoin, Lindsey
    Berant, Ron
    Shahar-Nissan, Keren
    Deanehan, J. Kate
    Lam, Samuel H. F.
    Snelling, Peter J.
    Avendano, Pablo
    Cohen, Stephanie G.
    Friedman, Nir
    Ekpenyong, Atim
    Pade, Kathryn H.
    Park, Daniel B.
    Lin-Martore, Margaret
    Kornblith, Aaron E.
    Montes-Amaya, Gerardo
    Thomas-Mohtat, Rosemary
    Jin, Jing
    Watson, Dave
    Sivitz, Adam
    ANNALS OF EMERGENCY MEDICINE, 2021, 78 (05) : 606 - 615
  • [44] A point-of-care thoracic ultrasound protocol for hospital medical emergency teams (METUS) improves diagnostic accuracy
    M.J, Blans
    E, Bousie
    van der J.G, Hoeven
    F.H, Bosch
    ULTRASOUND JOURNAL, 2021, 13 (01):
  • [45] A point-of-care thoracic ultrasound protocol for hospital medical emergency teams (METUS) improves diagnostic accuracy
    M. J Blans
    E Bousie
    J. G van der Hoeven
    F. H Bosch
    The Ultrasound Journal, 13
  • [46] Improving Point-of-Care Ultrasound Documentation and Billing Accuracy in a Pediatric Emergency Department
    Ng, Carrie
    Payne, Asha S.
    Patel, Amit K.
    Thomas-Mohtat, Rosemary
    Maxwell, Angela
    Abo, Alyssa
    PEDIATRIC QUALITY & SAFETY, 2020, 5 (04) : E315
  • [47] The Accuracy of Point-of-Care Ultrasound in Detecting Small Bowel Obstruction in Emergency Department
    Pourmand, A.
    Dimbil, U.
    Drake, A.
    Shokoohi, H.
    EMERGENCY MEDICINE INTERNATIONAL, 2018, 2018
  • [48] Accuracy of point-of-care ultrasound in the diagnosis of acute appendicitis in a pediatric emergency department
    Stefano, Balbo
    Cecilia Maria, Pini
    Irene, Raffaldi
    Angelo Giovanni, Delmonaco
    Emanuele, Castagno
    Riccardo, Guana
    Gianpaolo, Di Rosa
    Claudia, Bondone
    JOURNAL OF CLINICAL ULTRASOUND, 2024, 52 (05) : 485 - 490
  • [49] Just the Facts: Point-of-care ultrasound in the management of shoulder dislocations
    Henneberry, Ryan
    Dahn, Tara
    Atkinson, Paul
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2020, 22 (03) : 287 - 290
  • [50] Recommendations for the use of point-of-care ultrasound (POCUS) by emergency physicians in Canada
    Lewis, David
    Rang, Louise
    Kim, Daniel
    Robichaud, Laurie
    Kwan, Charisse
    Chau Pham
    Shefrin, Allan
    Ritcey, Brandon
    Atkinson, Paul
    Woo, Michael
    Jelic, Tomislav
    Dallaire, Genevieve
    Henneberry, Ryan
    Turner, Joel
    Andani, Rafiq
    Demsey, Roisin
    Olszynski, Paul
    CANADIAN JOURNAL OF EMERGENCY MEDICINE, 2019, 21 (06) : 721 - 726