Transcatheter closure or secundum atrial septal defects with the Amplatzer septal occluder: Early experience

被引:0
|
作者
Matitiau, A
Birk, E
Kachko, L
Blieden, LC
Bruckheimer, E
机构
[1] Schneider Childrens Med Ctr Israel, Pediat Cardiol Sect, IL-49292 Petah Tiqwa, Israel
[2] Kaplan Med Ctr, Rehovot, Israel
来源
ISRAEL MEDICAL ASSOCIATION JOURNAL | 2001年 / 3卷 / 01期
关键词
congenital heart defect; atrial septal defect; Amplatzer septal occluder; interventional catheterization; transcatheter closure;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Secundum atrial septal defect is a common congenital heart defect that causes right heart volume overload and produces symptoms usually after the third decade of life. Treatment until the last few years has been open heart surgery. Objectives: To review our early experience with transcatheter closure of ASD2 using the Amplatzer septal occluder. Methods: Between November 1999 and February 2000, 20 children and young adults with a median age of 9.1 years (4.2-35.1 years) were referred for transcatheter closure of ASD2. Diagnosis was established by transthoracic echocardiography. Implantation was performed under general anesthesia through the femoral vein with the guidance of transesophageal echocardiography and fluoroscopy. Femoral arterial puncture was performed for blood pressure monitoring during the procedure, The device size chosen was similar to the balloon-stretched diameter of the ASD2. Results: Implantation was completed successfully in 18 patients. Two patients were referred for elective surgery: one had an unsuitable anatomy for transcatheter closure by TEE in the catheterization laboratory and the device could not be implanted properly, the other patient had a large multi-perforated septal aneurysm that was retrieved. Mean ASD2 diameter by TTE and TEE was similar (13.9 +/- 3 mm, 13.4 +/- 3.5 mm) and mean stretched diameter was 18.3 +/- 4.3 mm. Mean Op:Qs (pulmonary flow:systemic flow) was 2.2 +/- 0.6. Mean fluoroscopy time for the procedure was 14.8 +/- 4.8 minutes. The patients were discharged the day after the procedure. Four patients had a tiny leak immediately post-procedure, and none had a leak at one month follow-up. The only complication was a small pseudoaneurysm of the femoral artery in one patient, that resolved spontaneously. Conclusions: Transcatheter closure of ASD2 with the Amplatzer septal occluder is a safe and effective alternative to surgical closure. Long-term outcome has to be evaluated.
引用
收藏
页码:32 / 35
页数:4
相关论文
共 50 条
  • [31] Transcatheter closure of secundum atrial septal defects using the amplatzer septal occluder: Results of phase IIUS multicenter clinical trial
    Hijazi, ZM
    Radtke, W
    Ebeid, MR
    Rocchini, AP
    Moore, JW
    Beekman, RH
    Slack, MC
    Balzer, D
    Wax, D
    Bass, J
    CIRCULATION, 1999, 100 (18) : 804 - 804
  • [32] Transvenous closure of moderate and large secundum atrial septal defects in adults using the Amplatzer septal occluder
    Demkow, M
    Ruzyllo, W
    Konka, M
    Kepka, C
    Kowalski, M
    Wilczynski, J
    Rydlewska-Sadowska, W
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 52 (02) : 188 - 193
  • [33] Transcatheter Closure of Large Secundum Atrial Septal Defects Using Amplatzer Septal Occlude in Adult
    Permatasari, I. G. A. Wijayanty
    Jaya, I. Pt Parwata
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0F) : F157 - F158
  • [34] The Amplatzer® Septal Occluder, a transcatheter device for atrial septal defect closure
    Fu, Yun-Ching
    Hijazi, Ziyad M.
    EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (01) : 25 - 31
  • [35] Factors Related to Successful Transcatheter Closure of Atrial Septal Defects Using the Amplatzer Septal Occluder
    Namrata Rastogi
    Nigel Charles Smeeton
    Shakeel Ahmed Qureshi
    Pediatric Cardiology, 2009, 30 : 888 - 892
  • [36] Transcatheter closure of secundum atrial septal defects using the new nitinol self-expandable, repositionable amplatzer septal occluder: Initial clinical experience
    Masura, J
    Walsh, KP
    Gavora, P
    Holan, M
    Hijazi, ZM
    CIRCULATION, 1997, 96 (08) : 3177 - 3177
  • [37] PERCUTANEOUS TRANSCATHETER CLOSURE OF DOUBLE ATRIAL SEPTAL DEFECTS WITH DOUBLE AMPLATZER SEPTAL OCCLUDER DEVICES
    Kaya, Zeynettin
    Ulgen, Mehmet Siddik
    Kayrak, Mehmet
    Goktekin, Omer
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 : S81 - S81
  • [38] Factors Related to Successful Transcatheter Closure of Atrial Septal Defects Using the Amplatzer Septal Occluder
    Rastogi, Namrata
    Smeeton, Nigel Charles
    Qureshi, Shakeel Ahmed
    PEDIATRIC CARDIOLOGY, 2009, 30 (07) : 888 - 892
  • [39] Transcatheter closure of secundum atrial septal defects
    Amin, Zahid
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (05) : 778 - 787
  • [40] Transcatheter Closure of Secundum Atrial Septal Defects
    Kazmouz, Suhaib
    Kenny, Damien
    Cao, Qi-Ling
    Kavinsky, Clifford J.
    Hijazi, Ziyad M.
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (05): : 257 - 264